⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Batteries

Discover Battery 48-48-5120

Побудувати систему з цим продуктом

Official manufacturer NA перевірено 20 вересня 2026 р.

Identity

category batteries
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation —
manufacturer Discover Battery
market_version AES RACKMOUNT 19-inch 3U module
model 48-48-5120
mpn 900-0062
product_family AES RACKMOUNT
product_status active
region —
release_year —
series AES LiFePO4
sku 900-0062

Electrical

bms —
capacity_ah 100
cell_chemistry LiFePO4
cell_configuration —
communication LYNK Port (CAN-based, RJ45 connector)
depth_of_discharge_pct —
expandable_to_kwh 30.72 (6 modules x 5.12 kWh)
max_charge_current_a 95 A (1 Hr); 70 A continuous
max_charge_power_w —
max_discharge_current_a 95 A (1 Hr); 70 A continuous
max_discharge_power_w —
modules_per_stack —
nominal_energy_kwh 5120 Wh (as printed)
nominal_voltage_v 51.2 V
parallel_units_max 24
peak_discharge 218 A RMS (3 seconds)
round_trip_efficiency_pct —
usable_energy_kwh —
voltage_range_v 40.0-55.2 V (discharge cut-off to bulk charge, as printed)

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm —
dimensions_mm 497.3 (L) x 439.2 (W, 19U) x 133.5 (H, 3U)
display —
enclosure_material —
height_mm —
mounting 19-inch rack, 3U
noise_db —
weight_kg 44.0 kg (97.0 lb)
width_mm —

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection IP20
max_altitude_m —
operating_temperature_c charge 4 to 52 (39.2°F to 125.6°F); discharge -17 to 52 (1.4°F to 125.6°F)
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app —
communication ['LYNK Port (CAN)']
dry_contact —
meter_interface —
monitoring_portal —
protocols []

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Certifications

standards ['UN38.3 Transportation', 'IEC62619', 'UL1973', 'UL9540A (pending)', 'UL9540 (pending)', 'EN61000-6-2', 'EN61000-6-3', 'FCC Class B', 'CE Marking']

Warranty & service

conditions Manual refers to warranty document 885-0043; terms not printed in this manual.
extension_options —
standard_years —

Документи

installation-manual AES RACKMOUNT INSTALLATION AND OPERATION MANUAL 805-0043 REVD rev 805-0043 REVD

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Discover AES RACKMOUNT manual, LYNK networkNetwork size limit: 30 total devices
Discover AES RACKMOUNT manual, Table 3-1Max Discharge Current (1 hour) 95 A; Max Charge Current (1 hour) 95 A; Charge Float Voltage (U2) 53.6 V; Charge Termination Current 2.5 A; Low Voltage Disconnect (Recommended) 48.0 V; Breaker Dual 100 A (2-pole ganged, K-curve)
Discover AES RACKMOUNT manual, Table 3-2 / 3-844.0 kg; 497.3x439.2x133.5 mm (3U, 19-inch front face 482.6 mm); Amphenol SurLok Plus terminals; IP20; UN38.3, IEC62619, UL1973, UL9540A (pending), UL9540 (pending), EN61000-6-2/-6-3, FCC Class B, CE
Discover AES RACKMOUNT manual, Table 3-7Parallel scaling: 2 modules 436 A peak / 140 A continuous / 10,240 Wh ... 6 modules 1308 A peak / 420 A continuous / 30,720 Wh
Max Charge Current (1 hour) / Max Discharge Current (1 hour)95 A / 95 A
Maximum parallel configuration (section 3.6)The maximum number of battery modules installed in a parallel configuration is 24.