Dyness Tower S3 TS10
Verified distributor global (EN documentation) перевірено 23 вересня 2026 р.
Identity
| category | batteries |
| ean | — |
| generation | S3 |
| hardware_revision | — |
| legacy_name | — |
| manufacturer | Dyness (Dyness Digital Energy Technology Co., LTD) суперечливе |
| market_version | EN |
| model | Tower S3 TS10 |
| mpn | — |
| product_family | Dyness Tower S3 (TS7 / TS10 / TS14 / TS17 / TS21, 192-576 V HV) |
| product_status | — |
| product_status_detail | current |
| product_status_evidence | Live official product page with full specification table at https://dyness.com/towers3-high-voltage-storage-battery-for-household-use (accessed 2026-09-02); official datasheet revision 2025-07-29 and compatibility list revision 2025-12-08 are linked from that page. |
| region | global (EN documentation) |
| release_year | — |
| sku | — |
| subcategory | high-voltage residential stacked battery SYSTEM (BDU control unit + N HV9637S modules) |
| variant_note | SYSTEM-level record. Tower S3 TS10 = 3 x HV9637S modules on one BDU. Same 37 Ah / 3.552 kWh module electrical class as the older Tower series but a different module part number (HV9637S vs HV9637), slightly lower system weight and a 20 mm taller enclosure per module step. The S3 system voltage range tops out at 108 V per module (324 V), 9 V per module lower than the older Tower's 328 V for the same module count. |
Electrical
| battery_chemistry |
LiFePO4
Dyness Tower S3 high-voltage residential battery (series page, covers TS7-TS21)
|
| cell_chemistry | LiFePO4 (manual: 'LFP' / 'Li-ion (LFP)') |
| cell_type | — |
| continuous_charge_current_a | 18.5 |
| continuous_discharge_current_a | 18.5 |
| continuous_power_kw | — |
| cycle_life | 6000 |
| cycle_life_cycles_min |
6000
Dyness Tower S3 high-voltage residential battery (series page, covers TS7-TS21)
|
| depth_of_discharge_pct | 95 |
| max_charge_current_a | — |
| max_charge_power_kw | 6.39 |
| max_discharge_current_a | 37 |
| max_discharge_power_kw | 10.66 |
| max_parallel_units |
12
Dyness Tower S3 high-voltage residential battery (series page, covers TS7-TS21)
|
| max_series_units | 6 |
| modules_per_tower_max | 6 |
| modules_per_tower_min | 2 |
| nominal_capacity_ah | 37 |
| nominal_energy_kwh |
10.66
Dyness Tower S3 high-voltage residential battery (series page, covers TS7-TS21)
|
| nominal_voltage_v | 288 |
| number_of_modules |
3
Dyness Tower S3 high-voltage residential battery (series page, covers TS7-TS21)
|
| official_manual_url |
https://www.elektrosmart.ro/wp-content/uploads/2025/11/Manual-de-instalare-Dyness-Tower-S3.pdf
Tower S3 ESS User Manual - distributor mirror on elektrosmart.ro
|
| official_product_url |
https://www.dyness.com/towers3-high-voltage-storage-battery-for-household-use
Tower S3 ESS User Manual - distributor mirror on elektrosmart.ro
|
| operating_voltage_max_v | 324 |
| operating_voltage_min_v | 252 |
| parallel_supported | True |
| peak_charge_current_a | 22 |
| peak_discharge_current_a | — |
| peak_power_kw | — |
| round_trip_efficiency_pct | — |
| series_supported | True |
| system_energy_max_kwh | 255.72 |
| system_energy_min_kwh | 7.1 |
| usable_energy_kwh | 10.127 |
Physical / mechanical
| color | — |
| cooling_method | — |
| depth_mm | 380 |
| enclosure_material | — |
| height_mm | 920.0 |
| installation_notes | Official page: '0 wiring, plug&play, allow one people to install'; 'Stackable auto-configuration modules, wireless connection.' |
| ip_rating | IP54 |
| length_mm |
380.0
Dyness Tower S3 high-voltage residential battery (series page, covers TS7-TS21)
|
| mounting_type | floor-standing stacked tower (BDU control unit + N HV9637S modules on a base) |
| rack_units | — |
| shipping_weight_kg | — |
| weight_kg | 143.0 |
| width_mm | 504.0 |
Installation
| clearance_notes | — |
| indoor_outdoor | indoor and outdoor (IP54) |
| notes | Official page: '0 wiring, plug&play, allow one people to install'. Maximum 12 Tower S3 clusters in parallel. |
| parallel_hub_required | No - clusters daisy-chain via the BDU 'Parallel 1#' and 'Parallel 2#' RJ45 ports |
Environment
| indoor_outdoor | indoor and outdoor (IP54; official page: 'Indoor & outdoor installations') |
| max_altitude_m | — |
| operating_humidity | — |
| operating_temperature_charge_max_c | 50 |
| operating_temperature_charge_min_c | 0 |
| operating_temperature_discharge_max_c | 50 |
| operating_temperature_discharge_min_c | -10 |
| operating_temperature_max_c | 50 |
| operating_temperature_min_c | -10 |
| pollution_degree | II (HV9637S module table) |
| storage_humidity | <65% RH |
| storage_temperature_max_c | 45 |
| storage_temperature_min_c | 5 |
Interfaces & connectors
| bluetooth | — |
| can | True |
| communication_ports | Inverter 'CAN/RS485 RJ45' on the BDU (manual Table 2-7 pin definitions); 'Parallel 1#' and 'Parallel 2#' RJ45 for multi-cluster |
| dry_contact | — |
| ethernet | — |
| modbus_rtu | — |
| modbus_tcp | — |
| protocol_notes | The fetched manual gives inverter CAN/RS485 RJ45 pin definitions (Table 2-7) but no baud rate or protocol identifier. |
| rs232 | — |
| rs485 | True |
| usb | — |
| wifi | — |
Protection
| fire_suppression | — |
| notes | Manual Table 2-1 'Short circuit current [kA]' = 1.5. |
| overcurrent | — |
| short_circuit_current_ka | 1.5 |
Certifications
| emc_certifications | CE-EMC (7SUN also lists CE-RED) |
| safety_certifications | IEC62619 / IEC63056 / IEC62477 / IEC62040 |
| standards | CE-EMC / CE-RED / IEC62040 / IEC62619 / IEC62477 / IEC63056 / UN38.3 |
| transport_certifications | UN38.3 |
Warranty & service
| conditions | — |
| summary | 10 years per the 7SUN and GVOLT distributor listings for the HV9637S module. No warranty period is printed in the fetched Tower S3 user manual or product page. |
| years | 10 |
Документи
compatibility_list
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Dyness Tower S3 Series Compatibility List 2025-12-08 - official — знайдено, не отримано
rev 20251208
datasheet
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Dyness Tower S3 Datasheet EN 2025-07-29 (TowerS3DatasheetEN20250729.pdf) - official, linked from the Tower S3 product page — знайдено, не отримано
rev 2025-07-29
distributor_listing
7SUN distributor listing: Battery module - DYNESS - HV9637S - S3 - 3.55 kWh - HV
rev UNKNOWN
Зафіксовані конфлікти
physical.weight_kg Resolved — accepted incoming value
143 — stored value
143.0 — Net Weight [kg] | 143kg
Detected during import wave4-2026-09-batch02
physical.height_mm Resolved — accepted incoming value
920 — stored value
920.0 — Dimensions [W*D*H] | 504*380*920 mm
Detected during import wave4-2026-09-batch02
physical.width_mm Resolved — accepted incoming value
504 — stored value
504.0 — Dimensions [W*D*H] | 504*380*920 mm
Detected during import wave4-2026-09-batch02
identity.manufacturer Review required
Dyness (Dyness Digital Energy Technology Co., LTD) — stored value
Dyness — incoming package
Detected during import wave4-2026-09-batch02
identity.manufacturer Review required
Dyness (Dyness Digital Energy Technology Co., LTD) — stored value
Dyness — incoming package
Detected during import v1-freeze-2026-09-batch02
identity.manufacturer Review required
Dyness (Dyness Digital Energy Technology Co., LTD) — stored value
Dyness — incoming package
Detected during import v1-freeze-2026-09-batch02
identity.manufacturer Review required
Dyness (Dyness Digital Energy Technology Co., LTD) — stored value
Dyness — incoming package
Detected during import v1-freeze-2026-09-batch02
identity.manufacturer Review required
Dyness (Dyness Digital Energy Technology Co., LTD) — stored value
Dyness — incoming package
Detected during import builder-critical-2026-09-batch02
identity.manufacturer Review required
Dyness (Dyness Digital Energy Technology Co., LTD) — stored value
Dyness — incoming package
Detected during import image-completion-2026-09-batch07
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Battery system charge current [A] (standard) | 7.4 A |
| Battery system charge voltage (V/DC) | 324 V |
| Battery system discharge current [A] (standard) | 7.4 A |
| Battery system discharge minimum voltage (V/DC) | 252 V |
| Battery system max charge & discharge current [A] | 22.5 A |
| Market experience claim (official page) | 'It has been market-verified for 5 years with 0 accidents.' |
| Max depth of discharge | 100% |
| Operating temperature (module table) | 0~55 C for the HV9637S module vs 0~50 C charge / -10~50 C discharge at system level |
| Optimal operating temperature | 18-30 C |
| Short circuit current [kA] | 1.5 kA |
| Storage SOC | 50 - 55% |
| Tower S3 manual, BDU naming | Tower S3 SBDU |
| Tower S3 manual, system table, 'Battery system max charge & discharge current (in communication with inverter)' | 22.5 A (all models) |
| builder_completeness | partial |
| identity.product_status | current |
| manufacturer_legal_entity_as_printed | Dyness Digital Energy Technology Co., LTD |
| region_notes | ANMA stores this record's region as free prose (e.g. 'global (EN documentation)'), which is not a region code; normalised to GLOBAL here and reported in identity_review. The product page opened is Dyness's English global site. |