⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Batteries

Pytes V12

Побудувати систему з цим продуктом

Official manufacturer GLOBAL перевірено 23 вересня 2026 р.

Identity

category batteries
manufacturer Pytes
model V12
region GLOBAL
variant —

Electrical

altitude_max_m 4000
battery_voltage_class LV
V12 Datasheet
bms_included Yes - DC breaker and pre-charge circuit integrated
bms_integrated True
V12 Datasheet
capacity_ah 230
V12 Datasheet
cell_chemistry LFP
chemistry LFP
V12 Datasheet
corrosion_resistance_class C4-M
cycle_life 6000
V12 Datasheet
depth_of_discharge_pct 90
V12 Datasheet
max_charge_current_a 100 (recommended, 5.12 kW)
max_charge_power_kw 5.12
V12 Datasheet
max_continuous_charge_current_a 100
V12 Datasheet
max_continuous_discharge_current_a 100
V12 Datasheet
max_discharge_current_a 100 (recommended, 5.12 kW)
max_discharge_power_kw 5.12
V12 Datasheet
nominal_capacity_kwh 11.776
V12 Datasheet
nominal_voltage_v 51.2
V12 Datasheet
operating_voltage_max_v 57.6
V12 Datasheet
operating_voltage_min_v 47.5
V12 Datasheet
peak_discharge_current_a 200
V12 Datasheet
peak_discharge_duration_s 180
terminal_type V12: Phoenix BPC250 quick connector; V12a: Amphenol SurLok Plus 8.0 mm
voltage_range_v 47.5-57.6
warranty_years 10 (basic warranty)

Physical / mechanical

dimensions_mm 640 x 230 x 520 (L x W x H)
weight_kg 100

Installation

mounting Wall or ground (with optional battery tray)

Environment

operating_temperature_range_c charge 0 to 55; discharge -20 to 55

Interfaces & connectors

communication_protocol RS485 / CAN / WiFi / dry contact
communications ['RS485', 'CAN', 'WiFi', 'Dry contact']
V12 Datasheet
documented_ports [{'port_role': 'RS485', 'port_label_from_manual': 'Communication Interface: RS485 / CAN / WIFI / Dry Contact', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specification table', 'quote': 'Communication Interface | RS485 / CAN / WIFI / Dry Contact'}, {'port_role': 'CAN', 'port_label_from_manual': 'Communication Interface: RS485 / CAN / WIFI / Dry Contact', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specification table', 'quote': 'Communication Interface | RS485 / CAN / WIFI / Dry Contact'}, {'port_role': 'WIFI', 'port_label_from_manual': 'Communication Interface: RS485 / CAN / WIFI / Dry Contact', 'port_type': 'Wi-Fi', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specification table', 'quote': 'Communication Interface | RS485 / CAN / WIFI / Dry Contact'}, {'port_role': 'DRY_CONTACT', 'port_label_from_manual': 'Dry Contact', 'port_type': 'dry contact', 'direction': 'output', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specification table', 'quote': 'Communication Interface | RS485 / CAN / WIFI / Dry Contact'}]

Protection

ingress_protection IP66
V12 Datasheet
protection_degree_ip IP66

Certifications

certifications UL 9540, UL 9540A, UL 1973, CEC, SGIP, IEC 62619, CE, UN 38.3

Документи

datasheet V12 Datasheet
manual V12 user manual-PYTES 1.0 20250722
product_page V12 Home Battery System
quick_start_guide V12 quick guide final - 0905-Q

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesOne worldwide datasheet; no market-specific electrical column is published.