Identity

category batteries
manufacturer SAJ
model B2-20.0-HV1
region EU
variant —

Electrical

battery_module_type BU2-5.0-HV1 (1P32S, 102.4 V, 50 Ah)
battery_voltage_class HV
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
capacity_ah 50
cell_chemistry LiFePO4
chemistry LiFePO4
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
control_module_type BC2-HV1, 200*626*365 mm, 11 kg
cooling Natural convection
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
cooling_method Natural convection
depth_of_discharge_pct 90
dimensions_h_w_d_mm 1044*626*365
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
max_charge_current_a 30
max_discharge_current_a 30
maximum_modules 4
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
minimum_modules 4
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
modules_in_system 4
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
nominal_capacity_kwh 20.0
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
nominal_voltage_v 409.6
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
number_of_modules 4
operating_humidity_pct 0-95 non-condensing
operating_voltage_max_v 460.8
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
operating_voltage_min_v 358.4
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
rated_power_w 12288
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
short_circuit_current_a <10000
usable_capacity_kwh 18.0
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
voltage_range_v 358.4-460.8
warranty_years 5/10

Physical / mechanical

dimensions_mm 1044*626*365
weight_kg 202
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU

Installation

mounting Wall-Mounted (optional)/Ground-Mounted суперечливе
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU

Environment

operating_temperature_charge_c 0 to 50
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
operating_temperature_discharge_c -10 to 50
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
operating_temperature_range_c 0 to 50 (charge); -10 to 50 (discharge)
storage_temperature_range_c -20 to 40

Interfaces & connectors

communication_protocol CAN
communications ['CAN']
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU

Protection

ingress_protection IP65
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
protection_degree_ip IP65

Certifications

certifications IEC 62619 (Cell & Pack), EN 62477-1, EN 61000-6-1/2/3/4, UN38.3
standards ['IEC 62619 (Cell&Pack)', 'EN 62477-1', 'EN 61000-6-1/2/3/4', 'UN38.3']
B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU

Документи

datasheet B2-(5-25K)-(HV1,HV5)-datasheet-EN-BEU
manual SAJ B2 Series User Manual (B2-5.0-HV1 to B2-25.0-HV1)
product_page B2 HV Series - SAJ Battery

Зафіксовані конфлікти

installation.mounting Review required
Wall-Mounted (optional)/Ground-Mounted — stored value
Wall-mounted / ground-mounted — incoming package
Detected during import deep-enrich-pass2-2026-09-batch14

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial