Sungrow MBH battery module (5.22 kWh)
Official manufacturer IEC / MEA / SEA перевірено 22 вересня 2026 р.
Identity
| category | batteries |
| generation | MBH |
| hardware_revision | — |
| legacy_name | — |
| manufacturer | Sungrow |
| market_version | Datasheet V3 MEA APAC (2026) |
| model | MBH battery module (5.22 kWh) |
| product_family | MBH (MBH20~75) |
| product_status | active |
| product_status_evidence | Component of the MBH range, itself active on datasheet V3 (2026) |
| region | IEC / MEA / SEA |
| release_year | — |
| sku | — |
| subcategory | battery module (component of an MBH cabinet) |
| variant_note | THIS IS THE MODULE, NOT A CABINET. Unlike the SBR and SBH modules, Sungrow prints this module's own voltage and Ah, so they are recorded as facts rather than derivations. |
Electrical
| architecture | Series element of a 4-15 module MBH stack |
| cell_chemistry | LiFePO4 |
| current_note | The 100 A figure is a SYSTEM/product-page figure and was not carried down to the module. |
| cycle_life | Up to 6,000 |
| cycle_life_note | Range-level claim. |
| expansion_rules | 'Scalable 4-15 module system, max 78 kWh' |
| firmware_requirements | — |
| max_charge_current_a | — |
| max_charge_power_kw | — |
| max_discharge_current_a | — |
| max_discharge_power_kw | — |
| max_parallel_stacks | — |
| mixed_generation_restrictions | — |
| module_capacity_ah | 102 |
| module_energy_kwh | 5.22 |
| modules_max | 15 |
| modules_min | 4 |
| nominal_energy_kwh | 5.22 |
| nominal_voltage_v | 51.2 |
| operating_voltage_max_v | — |
| operating_voltage_min_v | — |
| rated_power_kw | — |
| round_trip_efficiency_pct | — |
| usable_dod_pct | — |
| usable_energy_kwh | — |
Physical / mechanical
| cooling | Natural convection (as part of the cabinet) |
| depth_mm | — |
| dimensions_note | Module dimensions are not printed; only the cabinet's 534 x 1458/2030 x 560 mm. |
| height_mm | — |
| ip_rating | — |
| mounting | Stacked in the MBH cabinet |
| weight_kg | — |
| weight_note | NOT printed and deliberately NOT derived. The cabinet weights imply ~41 kg/module between MBH20 and MBH40 but ~47 kg/module between MBH40 and MBH75, because the range uses two different cabinet heights - so no single module mass can be honestly inferred. |
| width_mm | — |
Installation
| indoor_outdoor | Indoor (as part of the cabinet) |
| supported_installation_topology | Series element of one MBH cabinet |
Environment
| charge_temperature_c | 0 to 55 |
| discharge_temperature_c | -20 to 55 |
| humidity | 5 % to 85 % no condensing |
| max_altitude_m | 2000 |
| noise | — |
| storage_temperature_c | — |
| temperature_note | Inherited from the MBH cabinet datasheet; charge and discharge windows differ. |
Interfaces & connectors
| can | — |
| communication_protocol | — |
| ethernet | — |
| ports | Module interconnect; CAN/RS485 to the inverter is made at the cabinet. |
| rs485 | — |
Protection
| note | Protections documented at cabinet level ('21 protection functions', DC breaker, reverse connection protection). |
Certifications
| listed | ['IEC 62619', 'EN 61000-6-1', 'EN 61000-6-2', 'EN 61000-6-3', 'EN 61000-6-4', 'IEC 62477-1', 'UN 38.3'] |
| note | Certificates printed at cabinet level. |
Warranty & service
| years | — |
Документи
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| image_enrichment_pass | 2026-09-11 |
| manufacturer_legal_entity_as_printed | Sungrow Power Supply Co., Ltd. |