⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Battery Control Units

Dyness Tower BDU (Battery Distribution Unit) + Base

Verified distributor GLOBAL перевірено 22 вересня 2026 р.

Identity

category battery_control_units
description Battery controller unit that sits at the top of a Dyness Tower high-voltage battery stack, containing the DC breaker (master switch and short-circuit protection), power-on switch, power-wake button and the EXT-CAN RJ45 port to the inverter.
ean 2010000029497 (7SUN distributor listing)
generation —
gtin —
launch_year —
manufacturer Dyness (Daqin New Energy Tech (Taizhou) Co., Ltd.) суперечливе
marketing_name Dyness Tower BDU (control module)
model Tower BDU (Battery Distribution Unit) + Base
part_number ES-BC-EU (as listed by distributor 7SUN)
product_type battery distribution unit / system controller
region GLOBAL
series Tower
sku F12B2 (7SUN distributor SKU)
status —

Electrical

breaker_rating —
max_current —
note The 7SUN distributor page prints voltage figures (Tower T7 168-219V / 192V nominal, Tower T21 504-657V / 576V nominal, max continuous power 4.26-12.78kW). These are SYSTEM-level Tower figures, not BDU-only ratings; the distributor page conflates the two. They are therefore NOT asserted as BDU specifications and are preserved in raw_discovered instead.
official_product_url https://www.dyness.com/tower-high-voltage-storage-battery-for-household-use
Dyness Tower high-voltage residential battery (series page, covers T7-T21)
power_consumption —
supply_voltage_nominal —
supply_voltage_range —

Physical / mechanical

colour White (7SUN listing)
dimensions_mm 504*380*156.5
dimensions_source_note From the packing list of the Tower ESS Unit User Manual v3.3 - explicitly the BDU dimension.
enclosure_material —
mounting mounts on the Base at the bottom / head of the Tower stack
weight_kg —
weight_note The 7SUN distributor page prints 25.5 kg, but that page conflates Tower-system and BDU specifications, so it is not asserted here. Recorded in raw_discovered and data_conflicts.

Installation

installation_notes External power cable to the inverter; EXT-CAN RJ45 communication cable to the inverter.
mounting_type stacked Tower assembly on a Base

Environment

max_altitude_m —
note 7SUN prints charging 0 to 50degC and discharge -10 to 50degC - these are battery-cell temperature limits for the Tower system, not BDU environmental limits, and are not asserted here.
operating_temperature —
relative_humidity —
storage_temperature —

Interfaces & connectors

bluetooth —
can True
cloud_api —
communication_ports ['EXT-CAN communication port (RJ45)']
dry_contact —
ethernet False
local_api —
modbus_rtu —
modbus_tcp —
mqtt —
protocol_notes Tower ESS Unit User Manual v3.3 documents an EXT-CAN RJ45 port to the inverter. The 7SUN distributor page additionally claims CAN: Yes, RS485: Yes and RS232 supported. NO DIP switch table, address setting table or inverter protocol selection table exists anywhere in the Tower ESS Unit User Manual v3.3 - this was explicitly checked and is absent.
rs232 —
rs485 True
usb —
wifi —

Protection

ip_rating —
ip_rating_note 7SUN prints IP54, but for the Tower system as a whole; not asserted as a BDU rating.
overcurrent_protection DC breaker integrated in the BDU (master switch and short-circuit protection)
surge_protection —

Certifications

marks []
note 7SUN prints UN38.3/CE-EMC/IEC62040/IEC62619/IEC62477/IEC60730 for the Tower system; these are not asserted as BDU-specific certifications. Preserved in raw_discovered.
standards []

Warranty & service

note 7SUN prints 10 years, but for the Tower battery system; not asserted for the BDU.
terms —
years —

Документи

distributor_page Control module - DYNESS - BDU - ES-BC-EU (7SUN distributor page) rev UNKNOWN
product_page Dyness Tower high-voltage residential battery (series page, covers T7-T21)
user_manual Tower ESS Unit User Manual rev 3.3

Зафіксовані конфлікти

identity.manufacturer Review required
Dyness (Daqin New Energy Tech (Taizhou) Co., Ltd.) — stored value
Dyness — incoming package
Detected during import v1-freeze-2026-09-batch04
identity.manufacturer Review required
Dyness (Daqin New Energy Tech (Taizhou) Co., Ltd.) — stored value
Dyness — incoming package
Detected during import v1-freeze-2026-09-batch04
identity.manufacturer Review required
Dyness (Daqin New Energy Tech (Taizhou) Co., Ltd.) — stored value
Dyness — incoming package
Detected during import system-topology-2026-09-batch03
identity.manufacturer Review required
Dyness (Daqin New Energy Tech (Taizhou) Co., Ltd.) — stored value
Dyness — incoming package
Detected during import image-completion-2026-09-batch06
physical.weight_kg Review required
25.5 kg — 7SUN distributor BDU product page
UNKNOWN — Tower ESS Unit User Manual v3.3 - gives BDU dimensions in the packing list but no BDU weight

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

documented_relationship:control_unit_for_battery_system{"to_manufacturer": "Dyness", "to_model": "Tower (T7 / T10 / T14 / T17 / T21 high-voltage battery system)", "match_level": "series", "relationship_type": "control_unit_for_battery_system", "status": "manufacturer_documented", "source": "Tower ESS Unit User Manual v3.3", "source_url": "https://7sun.eu/wp-content/uploads/2025/06/Dyness-Tower-T7-T21-Manual.pdf", "confidence": "distributor-verified"}
manufacturer_legal_entity_as_printedDaqin New Energy Tech (Taizhou) Co., Ltd.