⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Battery Management Systems

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category battery_management_systems
manufacturer EMUS BMS
model BMS Mini 1
region GLOBAL
variant —

Electrical

balancing_condition ~200mA @ 3.4V
BMS Mini 1
balancing_current_ma 200
BMS Mini 1
charge_current_continuous_a 90
BMS Mini 1
current_rating_condition Tested at 50 °C, without radiator
BMS Mini 1
digital_inputs 4
BMS Mini 1
digital_outputs 4
BMS Mini 1
discharge_current_continuous_a 90
BMS Mini 1
internal_dcdc Built-in 5V / 12V DC/DC converter
BMS Mini 1
max_cells_series 16
BMS Mini 1
max_charge_current_a 90
BMS Mini 1
max_discharge_current_a 90
BMS Mini 1
max_parallel_units 32
BMS Mini 1
min_cells_series 3
BMS Mini 1
part_numbers ['MNC110']
BMS Mini 1
short_circuit_detection_time_us 30
BMS Mini 1
short_circuit_detection_us 30
BMS Mini 1
sleep_consumption 60μA (16s); 240μA (3s)
BMS Mini 1
software_compliance MISRA C:2012 / Unit-Tested
BMS Mini 1
supported_cell_count 3 – 16 Cells in Series
BMS Mini 1

Environment

temperature_inputs 4
BMS Mini 1

Interfaces & connectors

can True
BMS Mini 1
communications ['CAN Bus', 'RS485']
BMS Mini 1
documented_ports [{'port_role': 'CAN', 'port_label_from_manual': 'CAN Bus', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces' (product page for BMS Mini 1)", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces'", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital/Analog I/O Inputs', 'port_type': 'digital/analog input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital/Analog I/O Outputs', 'port_type': 'digital/analog output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}]
rs485 True
BMS Mini 1

Документи

product_page BMS Mini 1

Зафіксовані конфлікти

interfaces.documented_ports Resolved — kept current value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN Bus', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces' (product page for BMS Mini 1)", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces'", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital/Analog I/O Inputs', 'port_type': 'digital/analog input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital/Analog I/O Outputs', 'port_type': 'digital/analog output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}] — stored value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN Bus', 'port_type': 'CAN', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communication Interfaces', 'quote': 'CAN Bus, RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communication Interfaces', 'quote': 'CAN Bus, RS485'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Programmable Inputs', 'port_type': 'Digital input', 'direction': 'INPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Programmable I/O', 'quote': '4 Inputs / 4 Outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Programmable Outputs', 'port_type': 'Digital output', 'direction': 'OUTPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Programmable I/O', 'quote': '4 Inputs / 4 Outputs'}, {'port_role': 'TEMPERATURE_SENSOR', 'port_label_from_manual': 'dedicated temperature sensors', 'port_type': 'Temperature sensor input', 'direction': 'INPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Temperature Sensors', 'quote': '4 dedicated temperature sensors'}] — incoming package
Detected during import deep-enrich-2026-09-batch06

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesLithuanian manufacturer; one worldwide specification, DC-side device.