База знань › Battery Management Systems
EMUS BMS BMS Mini 1
Official manufacturer GLOBAL перевірено 25 вересня 2026 р.
Identity
| category | battery_management_systems |
| manufacturer | EMUS BMS |
| model | BMS Mini 1 |
| region | GLOBAL |
| variant | — |
Electrical
| balancing_condition |
~200mA @ 3.4V
BMS Mini 1
|
| balancing_current_ma |
200
BMS Mini 1
|
| charge_current_continuous_a |
90
BMS Mini 1
|
| current_rating_condition |
Tested at 50 °C, without radiator
BMS Mini 1
|
| digital_inputs |
4
BMS Mini 1
|
| digital_outputs |
4
BMS Mini 1
|
| discharge_current_continuous_a |
90
BMS Mini 1
|
| internal_dcdc |
Built-in 5V / 12V DC/DC converter
BMS Mini 1
|
| max_cells_series |
16
BMS Mini 1
|
| max_charge_current_a |
90
BMS Mini 1
|
| max_discharge_current_a |
90
BMS Mini 1
|
| max_parallel_units |
32
BMS Mini 1
|
| min_cells_series |
3
BMS Mini 1
|
| part_numbers |
['MNC110']
BMS Mini 1
|
| short_circuit_detection_time_us |
30
BMS Mini 1
|
| short_circuit_detection_us |
30
BMS Mini 1
|
| sleep_consumption |
60μA (16s); 240μA (3s)
BMS Mini 1
|
| software_compliance |
MISRA C:2012 / Unit-Tested
BMS Mini 1
|
| supported_cell_count |
3 – 16 Cells in Series
BMS Mini 1
|
Environment
| temperature_inputs |
4
BMS Mini 1
|
Interfaces & connectors
| can |
True
BMS Mini 1
|
| communications |
['CAN Bus', 'RS485']
BMS Mini 1
|
| documented_ports | [{'port_role': 'CAN', 'port_label_from_manual': 'CAN Bus', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces' (product page for BMS Mini 1)", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces'", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital/Analog I/O Inputs', 'port_type': 'digital/analog input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital/Analog I/O Outputs', 'port_type': 'digital/analog output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}] |
| rs485 |
True
BMS Mini 1
|
Документи
product_page
BMS Mini 1
Зафіксовані конфлікти
interfaces.documented_ports Resolved — kept current value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN Bus', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces' (product page for BMS Mini 1)", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': "Specifications table, row 'Communication Interfaces'", 'quote': 'Communication Interfaces | CAN Bus, RS485'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital/Analog I/O Inputs', 'port_type': 'digital/analog input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital/Analog I/O Outputs', 'port_type': 'digital/analog output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': "Specifications table, row 'Digital/Analog I/O'", 'quote': 'Digital/Analog I/O | 4 Inputs / 4 Outputs'}] — stored value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN Bus', 'port_type': 'CAN', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communication Interfaces', 'quote': 'CAN Bus, RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS-485', 'direction': 'BIDIRECTIONAL', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Communication Interfaces', 'quote': 'CAN Bus, RS485'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Programmable Inputs', 'port_type': 'Digital input', 'direction': 'INPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Programmable I/O', 'quote': '4 Inputs / 4 Outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Programmable Outputs', 'port_type': 'Digital output', 'direction': 'OUTPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Programmable I/O', 'quote': '4 Inputs / 4 Outputs'}, {'port_role': 'TEMPERATURE_SENSOR', 'port_label_from_manual': 'dedicated temperature sensors', 'port_type': 'Temperature sensor input', 'direction': 'INPUT', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'Temperature Sensors', 'quote': '4 dedicated temperature sensors'}] — incoming package
Detected during import deep-enrich-2026-09-batch06
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | Lithuanian manufacturer; one worldwide specification, DC-side device. |