⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Battery Management Systems

Manufacturer documented NA перевірено 25 вересня 2026 р.

Identity

category battery_management_systems
manufacturer Thunderstruck Motors
model MCU
region —
variant —

Electrical

can_baud_rate_kbps [250, 500]
Master Control Unit
can_baud_rates 250 kbps or 500 kbps
Master Control Unit
can_interfaces 2
Master Control Unit
can_port_count 2
Master Control Unit
cell_balancing True
Master Control Unit
chargers_controlled 4
Master Control Unit
current_sensor Hall sensor for current counting SOC reporting
Master Control Unit
digital_input_count 5
Master Control Unit
digital_output_count 5
Master Control Unit
dimensions_in 4.1 x 2.65 x 1.1
Master Control Unit
evse_compatibility J1772 Type 1 and Type 2
Master Control Unit
height_in 1.1
Master Control Unit
isospi_interfaces 2
Master Control Unit
isospi_port_count 2
Master Control Unit
length_in 4.1
Master Control Unit
max_cells_series 288
Master Control Unit
min_cells_series 4
Master Control Unit
programmable_inputs 5
Master Control Unit
programmable_outputs 5
Master Control Unit
satellite_types 24-cell or 18-cell satellites
Master Control Unit
supply_voltage_v 12
MCU Manual
supported_cell_count 288
Master Control Unit
supported_cell_count_min 4
Master Control Unit
width_in 2.65
Master Control Unit

Physical / mechanical

enclosure_material plastic enclosure with mounting flanges
Master Control Unit

Interfaces & connectors

can True
Master Control Unit
documented_ports [{'port_role': 'CAN', 'port_label_from_manual': 'CAN1', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN2', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'IsoSPI', 'port_type': 'IsoSPI', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Features', 'quote': 'Two IsoSPI interfaces for connecting multiple 24-cell or 18-cell satellites'}, {'port_role': 'AUX', 'port_label_from_manual': 'Connector A, pins 1 and 2 (12V / GND)', 'port_type': 'Harting 14311013101000 10-pin', 'direction': 'input', 'electrical_domain': 'dc', 'document': 1, 'page': 'Connectors', 'quote': "12V (input) and GND (Connector A, pins 1 and 2) provide 'always on' power."}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': '12v switched output', 'port_type': 'Switched 12 V output', 'direction': 'output', 'electrical_domain': 'dc', 'document': 0, 'page': 'Features', 'quote': '12v switched output for controlling an external device'}]
protocols CANOpen and OBDII
Master Control Unit

Документи

installation_manual MCU Wiring Diagram
product_page Master Control Unit
user_manual MCU Manual

Зафіксовані конфлікти

interfaces.documented_ports Resolved — accepted incoming value
[{'port_role': 'CAN', 'port_label_from_manual': 'CANbus Interfaces', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Master Control Unit product description (thunderstruck-ev.com/mcu.html)', 'quote': 'CANbus Interfaces: Two independent networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'IsoSPI Interfaces', 'port_type': 'isoSPI', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'IsoSPI Interfaces: Two for connecting multiple 24-cell or 18-cell satellites'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'programmable inputs', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 5, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'Programmable I/O: Five programmable inputs and five programmable outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'programmable outputs', 'port_type': 'digital output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 5, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'Programmable I/O: Five programmable inputs and five programmable outputs'}, {'port_role': 'CT', 'port_label_from_manual': 'Current Sensor Input', 'port_type': 'Hall sensor input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'Current Sensor Input: Hall sensor for current counting SOC reporting'}] — stored value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN1', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN2', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'IsoSPI', 'port_type': 'IsoSPI', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Features', 'quote': 'Two IsoSPI interfaces for connecting multiple 24-cell or 18-cell satellites'}, {'port_role': 'AUX', 'port_label_from_manual': 'Connector A, pins 1 and 2 (12V / GND)', 'port_type': 'Harting 14311013101000 10-pin', 'direction': 'input', 'electrical_domain': 'dc', 'document': 1, 'page': 'Connectors', 'quote': "12V (input) and GND (Connector A, pins 1 and 2) provide 'always on' power."}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': '12v switched output', 'port_type': 'Switched 12 V output', 'direction': 'output', 'electrical_domain': 'dc', 'document': 0, 'page': 'Features', 'quote': '12v switched output for controlling an external device'}] — incoming package
Detected during import deep-enrich-2026-09-batch06
interfaces.protocols Resolved — accepted incoming value
['CANopen', 'OBDII'] — stored value
CANOpen and OBDII — CANOpen and OBDII Support
Detected during import deep-enrich-2026-09-batch06

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesManufactured and sold by Thunderstruck Motors, Santa Rosa, California; supports J1772 Type 1 and Type 2 EVSE.