База знань › Battery Management Systems
Thunderstruck Motors MCU
Manufacturer documented NA перевірено 25 вересня 2026 р.
Identity
| category | battery_management_systems |
| manufacturer | Thunderstruck Motors |
| model | MCU |
| region | — |
| variant | — |
Electrical
| can_baud_rate_kbps |
[250, 500]
Master Control Unit
|
| can_baud_rates |
250 kbps or 500 kbps
Master Control Unit
|
| can_interfaces |
2
Master Control Unit
|
| can_port_count |
2
Master Control Unit
|
| cell_balancing |
True
Master Control Unit
|
| chargers_controlled |
4
Master Control Unit
|
| current_sensor |
Hall sensor for current counting SOC reporting
Master Control Unit
|
| digital_input_count |
5
Master Control Unit
|
| digital_output_count |
5
Master Control Unit
|
| dimensions_in |
4.1 x 2.65 x 1.1
Master Control Unit
|
| evse_compatibility |
J1772 Type 1 and Type 2
Master Control Unit
|
| height_in |
1.1
Master Control Unit
|
| isospi_interfaces |
2
Master Control Unit
|
| isospi_port_count |
2
Master Control Unit
|
| length_in |
4.1
Master Control Unit
|
| max_cells_series |
288
Master Control Unit
|
| min_cells_series |
4
Master Control Unit
|
| programmable_inputs |
5
Master Control Unit
|
| programmable_outputs |
5
Master Control Unit
|
| satellite_types |
24-cell or 18-cell satellites
Master Control Unit
|
| supply_voltage_v |
12
MCU Manual
|
| supported_cell_count |
288
Master Control Unit
|
| supported_cell_count_min |
4
Master Control Unit
|
| width_in |
2.65
Master Control Unit
|
Physical / mechanical
| enclosure_material |
plastic enclosure with mounting flanges
Master Control Unit
|
Interfaces & connectors
| can |
True
Master Control Unit
|
| documented_ports | [{'port_role': 'CAN', 'port_label_from_manual': 'CAN1', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN2', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'IsoSPI', 'port_type': 'IsoSPI', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Features', 'quote': 'Two IsoSPI interfaces for connecting multiple 24-cell or 18-cell satellites'}, {'port_role': 'AUX', 'port_label_from_manual': 'Connector A, pins 1 and 2 (12V / GND)', 'port_type': 'Harting 14311013101000 10-pin', 'direction': 'input', 'electrical_domain': 'dc', 'document': 1, 'page': 'Connectors', 'quote': "12V (input) and GND (Connector A, pins 1 and 2) provide 'always on' power."}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': '12v switched output', 'port_type': 'Switched 12 V output', 'direction': 'output', 'electrical_domain': 'dc', 'document': 0, 'page': 'Features', 'quote': '12v switched output for controlling an external device'}] |
| protocols |
CANOpen and OBDII
Master Control Unit
|
Документи
installation_manual
MCU Wiring Diagram
product_page
Master Control Unit
user_manual
MCU Manual
Зафіксовані конфлікти
interfaces.documented_ports Resolved — accepted incoming value
[{'port_role': 'CAN', 'port_label_from_manual': 'CANbus Interfaces', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Master Control Unit product description (thunderstruck-ev.com/mcu.html)', 'quote': 'CANbus Interfaces: Two independent networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'IsoSPI Interfaces', 'port_type': 'isoSPI', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'IsoSPI Interfaces: Two for connecting multiple 24-cell or 18-cell satellites'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'programmable inputs', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 5, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'Programmable I/O: Five programmable inputs and five programmable outputs'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'programmable outputs', 'port_type': 'digital output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 5, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'Programmable I/O: Five programmable inputs and five programmable outputs'}, {'port_role': 'CT', 'port_label_from_manual': 'Current Sensor Input', 'port_type': 'Hall sensor input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Master Control Unit product description', 'quote': 'Current Sensor Input: Hall sensor for current counting SOC reporting'}] — stored value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN1', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN2', 'port_type': 'CANbus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Connector description', 'quote': 'Two independent canbus networks configurable for 250 kbps or 500 kbps baud rates'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'IsoSPI', 'port_type': 'IsoSPI', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Features', 'quote': 'Two IsoSPI interfaces for connecting multiple 24-cell or 18-cell satellites'}, {'port_role': 'AUX', 'port_label_from_manual': 'Connector A, pins 1 and 2 (12V / GND)', 'port_type': 'Harting 14311013101000 10-pin', 'direction': 'input', 'electrical_domain': 'dc', 'document': 1, 'page': 'Connectors', 'quote': "12V (input) and GND (Connector A, pins 1 and 2) provide 'always on' power."}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': '12v switched output', 'port_type': 'Switched 12 V output', 'direction': 'output', 'electrical_domain': 'dc', 'document': 0, 'page': 'Features', 'quote': '12v switched output for controlling an external device'}] — incoming package
Detected during import deep-enrich-2026-09-batch06
interfaces.protocols Resolved — accepted incoming value
['CANopen', 'OBDII'] — stored value
CANOpen and OBDII — CANOpen and OBDII Support
Detected during import deep-enrich-2026-09-batch06
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | Manufactured and sold by Thunderstruck Motors, Santa Rosa, California; supports J1772 Type 1 and Type 2 EVSE. |