⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Battery Management Systems

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category battery_management_systems
manufacturer Victron Energy
model Smart BMS 12-200
region GLOBAL
variant —

Electrical

alternator_port_max_charge_current_a 100
Smart BMS 12/200
battery_compatibility Victron Lithium Battery Smart 12,8 V (nominal 12.8 V); maximum 20 batteries in one system, up to 84 kWh in a 12 V system
bms_integrated True
BMS Overview (comparison datasheet)
charge_disconnect_output Normally high (Vbat - 0.1 V), source current limit 10 mA, sink 0 A
Smart BMS 12/200
current_consumption_remote_off 6.5mA (BMS functionality still active); 4.5 mA (BMS functionality disabled)
Smart BMS 12/200
current_consumption_remote_off_ma 6.5 (BMS functionality still active) / 4.5 (BMS functionality disabled)
current_consumption_remote_on_ma 17.5
Smart BMS 12/200
dc_connector_battery_minus Faston female, 6.3 mm
dc_power_connection M8
dimensions_hxwxd_mm 65 x 120 x 340 mm
Smart BMS 12/200
firmware_updatable True
BMS Overview (comparison datasheet)
input_voltage_to_start_charging_v > 13
load_disconnect_output Normally high (Vbat - 0.1 V), source current limit 10 mA, sink 0 A
Smart BMS 12/200
max_continuous_current_a 200
peak_discharge_current_a 400
Smart BMS 12/200
pre_alarm_output Normally free floating; high in case of alarm, max. 1 A суперечливе
Smart BMS 12/200
remote_on_off_terminal True
BMS Overview (comparison datasheet)
system_port_max_charge_discharge_current_a 200
Smart BMS 12/200
system_voltage_v 12
BMS Overview (comparison datasheet)

Physical / mechanical

dimensions_mm 65 x 120 x 340 (h x w x d)
weight_kg 2.0
Smart BMS 12/200

Installation

mounting_torque_nm 10

Environment

humidity 100 % maximum / 95 % average
operating_temperature_range_c -40 to +60
Smart BMS 12/200

Interfaces & connectors

bluetooth True
BMS Overview (comparison datasheet)
communication_protocol Bluetooth, for monitoring and configuration via the VictronConnect app, with Instant Readout
communications ['Bluetooth']
BMS Overview (comparison datasheet)
documented_ports [{'port_role': 'DC_IN', 'port_label_from_manual': 'Alternator port', 'port_type': 'M8 stud', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_current_a': 100, 'document': 1, 'page': 'Specifications', 'quote': 'Alternator port - max charge current | 100 A (with 125 A fuse)'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'System+ port', 'port_type': 'M8 stud', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 1, 'max_current_a': 200, 'document': 1, 'page': 'Specifications', 'quote': 'System+ port - max charge and discharge current | 200 A'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Remote on/off terminal', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': 'Comparison table', 'quote': 'Remote on/off terminal | Smart BMS 12/200 column | Yes'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Load disconnect output', 'port_type': 'free-floating/high output', 'direction': 'output', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specifications', 'quote': 'Load disconnect output - Source current limit | 10 mA (short circuit protected)'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Charge disconnect output', 'port_type': 'free-floating/high output', 'direction': 'output', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specifications', 'quote': 'Charge disconnect output - Source current limit | 10 mA (short circuit protected)'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Pre-alarm output', 'port_type': 'free-floating/high output', 'direction': 'output', 'electrical_domain': 'communication', 'document': 1, 'page': 'Specifications', 'quote': 'Pre-alarm output - High (in case of alarm) | max. 1 A (not short circuit proof)'}, {'port_role': 'BLUETOOTH', 'port_label_from_manual': 'Bluetooth', 'port_type': 'Bluetooth', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': 'Comparison table', 'quote': 'Bluetooth | Smart BMS 12/200 column | Yes'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'DC connector battery minus', 'port_type': 'Faston female, 6.3 mm', 'direction': 'output', 'electrical_domain': 'DC', 'document': 1, 'page': 'Specifications', 'quote': 'DC connector battery minus | Faston female, 6.3 mm'}]

Protection

ingress_protection IP65
Smart BMS 12/200
protection_degree_ip IP65 (electronics)
protections Monitors each individual battery cell and disconnects the alternator, charge sources or DC loads in case of low or high battery cell voltage or high temperature; pre-alarm output warns before the BMS disconnects the batteries

Certifications

certifications Emission: EN 61000-6-3, EN 55014-1. Immunity: EN 61000-6-2, EN 61000-6-1, EN 55014-2. Automotive Directive: ECE R10-5

Документи

datasheet BMS Overview (comparison datasheet)
datasheet Smart BMS 12/200
manual Smart BMS 12-200 manual (HTML), chapter Specifications
manual Smart BMS 12-200 manual (PDF)
product_page Smart BMS 12-200 product page

Зафіксовані конфлікти

electrical.pre_alarm_output Review required
Normally free floating; high in case of alarm, max. 1 A — stored value
High (Vbat) in case of alarm, max. 1 A — incoming package
Detected during import deep-enrich-pass2-2026-09-batch06
electrical.charge_disconnect_output Resolved — kept current value
Normally high (Vbat - 0.1 V), source current limit 10 mA, sink 0 A — stored value
Normally high (Vbat – 0.1 V); source current limit 10 mA (short circuit protected); sink current 0 A (output free floating) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch06
electrical.load_disconnect_output Resolved — kept current value
Normally high (Vbat - 0.1 V), source current limit 10 mA, sink 0 A — stored value
Normally high (Vbat – 0.1 V); source current limit 10 mA (short circuit protected); sink current 0 A (output free floating) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch06
electrical.current_consumption_remote_on_ma Resolved — kept current value
17.5 — stored value
17.5 (excluding Load output and Charge output current) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch06
electrical.alternator_port_max_charge_current_a Resolved — kept current value
100 — stored value
100 (with a 125 A fuse) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch06

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesVictron publishes one worldwide datasheet and manual for this unit; ANMA's existing Victron BMS entries are all global.