База знань ›
Battery Monitors
Official manufacturer
GLOBAL
перевірено 25 вересня 2026 р.
PRODUCT PHOTO · Victron Energy
Identity
category
battery_monitors
manufacturer
Victron Energy
model
BMV-700
product_family
BMV-700 series
product_status
active
region
global
sku
BAM010700000
Electrical
amp_hours_resolution
± 0.1 Ah
auxiliary_input_voltage_range_vdc
Not applicable - no auxiliary input
battery_capacity_range_ah
1 - 9999 Ah
battery_voltage_measuring_range
—
current_draw
< 4mA
current_measurement_accuracy
± 0.4 %
current_measuring_range
—
current_resolution
± 0.01 A
official_product_url
https://www.victronenergy.com/battery-monitors/bmv-700
BMV-700 series — Victron Energy product page
optional_shunt_ratings
1000A/50mV, 2000A/50mV and 6000A/50mV shunt
relay
60V / 1A normally open (function can be inverted)
shunt_rating_a
500
shunt_rating_label
500 A / 50 mV (included)
state_of_charge_resolution
± 0.1 %
supply_voltage_range_vdc
6.5 - 95 Vdc
temperature_resolution
± 1 °C/°F
time_to_go_resolution
± 1 min
voltage_measurement_accuracy
± 0.3 %
voltage_resolution
± 0.01 V
Physical / mechanical
cables_included
10 meter 6 core UTP with RJ12 connectors; cable(s) with 1A slow blow fuse
head_unit_bezel
69 x 69mm (2.7 x 2.7 inch)
head_unit_body
52mm (2.0 inch) diameter and 31mm (1.2 inch) depth
head_unit_front_diameter
63mm (2.5 inch)
installation
Flush mount
shunt_connection_bolts
M10 (0.3937 inch)
shunt_dimensions_mm
—
weight
—
Installation
auxiliary_input_functions
None - this model has no auxiliary input
temperature_sensor
Not supported
Environment
humidity
—
operating_temperature_range
-40 +50 °C (-40 - 120 °F)
Interfaces & connectors
bluetooth
No
ethernet
No
modbus_rtu
—
modbus_tcp
—
rs485
—
ve_direct
Yes
ve_smart_network
No
Protection
fuse
1 A slow blow fuse in supplied cable
ip_rating
IP55 (not intended for outdoor use) - head unit
Certifications
standards
['EN 60335-1 (Safety)', 'EN 55014-1 / EN 55014-2 (Emission/Immunity)', 'ECE R10-4', 'EN 50498 (Automotive)']
Warranty & service
summary
5-year standard warranty
Документи
manual-pdf
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Manual - BMV and SmartShunt (shared manual) — знайдено, не отримано
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
Article number suffix (R) also available in retail packaging
Head unit body 52 mm (2.0 inch) diameter and 31 mm (1.2 inch) depth
Installation Flush mount
Time-to-go ± 1 min
builder_completeness partial
image_enrichment_pass 2026-09-11 promote-existing-to-primary