⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Current Transformers (CT)

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category current_transformers
manufacturer Accuenergy
model AcuCT-075-150: 333mV
region GLOBAL
variant —

Electrical

accuracy_class 1.00% (ratio accuracy at rated current) суперечливе
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
accuracy_percent 1.0
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
aperture_mm 19.0 x 19.0 суперечливе
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
cable_length_m 2.5
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
conductor_size_mm window 19.0 x 19.0 mm (0.75 in x 0.75 in)
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
ct_type split_core суперечливе
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
current_range 5% - 120% of Rated Current
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
flammability_rating UL 94V-0
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
frequency_hz 50/60 суперечливе
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
housing_material Epoxy Encapsulated Housing, UL 94V-0
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
lead_description 2.5m (8ft) Twisted Pair, 22AWG
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
lead_wires 2.5 m (8 ft) twisted pair, 22 AWG
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
measurement_category CAT III
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
operating_humidity Non-Condensing, 0 to 95% RH
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
primary_current_a 150
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
rated_insulation_voltage_v 600
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
ratio 150 A / 333 mV суперечливе
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
secondary_voltage_mv 333
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
window_size 19.0mm x 19.0mm (0.75" x 0.75")
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
withstand_voltage 3.0KV / 1mA / 1min
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet

Physical / mechanical

dimensions_mm 50.8mm x 53.3mm x 17.0mm
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet

Environment

operating_temperature_max_c 55
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
operating_temperature_min_c -20
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet

Certifications

certifications ['CE', 'RoHS', 'cURus (E359521)']
AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet

Документи

datasheet AcuCT mV Series - AcuCT-075 333mV Split-Core Current Transformer Datasheet
datasheet AcuCT mV Series 333mV Split-Core Current Transformer Datasheet (all window sizes)
installation_manual AcuCT mV Series 333mV Split-Core Current Transformer Installation Guide
product_page AcuCT mV Series 333mV Split-Core Current Transformers - product page

Зафіксовані конфлікти

electrical.aperture_mm Review required
19.0 x 19.0 — stored value
19.0 — 19.0mm x 19.0mm (0.75" x 0.75")
Detected during import deep-enrich-2026-09-batch08
electrical.ratio Review required
150 A / 333 mV — stored value
150/333mV — AcuCT-075-150: 333mV | 150/333mV | 1.00% | 2.5m
Detected during import deep-enrich-2026-09-batch08
electrical.frequency_hz Review required
50/60 — stored value
[50, 60] — 50/60Hz
Detected during import deep-enrich-2026-09-batch08
electrical.accuracy_class Review required
1.00% (ratio accuracy at rated current) — stored value
1.00% — 1.00%
Detected during import deep-enrich-2026-09-batch08
electrical.ct_type Review required
split_core — stored value
Split Core — AcuCT-075 333mV Split Core Current Transformer datasheet
Detected during import deep-enrich-2026-09-batch08

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesscomplete
region_notesAccuenergy publishes one specification for the AcuCT-075 with CE, RoHS and cURus marks; GLOBAL.