category current_transformers
manufacturer DENT Instruments
model CT-SCM-0100-U
region GLOBAL
variant —

Electrical

accuracy_class No IEC class printed; ratio error <1% at rated current (typical)
100/200/600A Medium Split-Core CT Data Sheet
aperture_cm 3.2
100/200/600A Medium Split-Core CT Data Sheet
aperture_in 1.25
100/200/600A Medium Split-Core CT Data Sheet
aperture_mm 32.0
100/200/600A Medium Split-Core CT Data Sheet
cable_length_m 3
100/200/600A Medium Split-Core CT Data Sheet
ct_type split_core суперечливе
100/200/600A Medium Split-Core CT Data Sheet
dielectric_strength 5000 VAC around case
100/200/600A Medium Split-Core CT Data Sheet
dielectric_withstand_v 5000
100/200/600A Medium Split-Core CT Data Sheet
dimensions_cm 8.26 x 8.51 x 2.54
100/200/600A Medium Split-Core CT Data Sheet
frequency_hz 50-400 суперечливе
100/200/600A Medium Split-Core CT Data Sheet
housing_material Epoxy encapsulated housing
100/200/600A Medium Split-Core CT Data Sheet
lead_description 3 M (9.8'), twisted pair, 20 AWG
100/200/600A Medium Split-Core CT Data Sheet
measurement_category CAT III суперечливе
100/200/600A Medium Split-Core CT Data Sheet
measuring_range 5 to 130A AC
100/200/600A Medium Split-Core CT Data Sheet
phase_error <2° at rated current (typical)
100/200/600A Medium Split-Core CT Data Sheet
phase_error_deg <2° at rated current (typical)
100/200/600A Medium Split-Core CT Data Sheet
primary_current_a 100
100/200/600A Medium Split-Core CT Data Sheet
rated_insulation_voltage_v 600
100/200/600A Medium Split-Core CT Data Sheet
ratio 100 A : 333 mV
100/200/600A Medium Split-Core CT Data Sheet
ratio_error <1% at rated current (typical)
100/200/600A Medium Split-Core CT Data Sheet
secondary_voltage_mv 333
100/200/600A Medium Split-Core CT Data Sheet
window_size 1.25" (3.20 cm)
100/200/600A Medium Split-Core CT Data Sheet

Environment

operating_temperature_max_c 55
100/200/600A Medium Split-Core CT Data Sheet
operating_temperature_min_c -20
100/200/600A Medium Split-Core CT Data Sheet

Certifications

standards UL STD 61010-1, EN 60044-1, CAN/CSA STD C22.2 No. 61010-1 суперечливе
100/200/600A Medium Split-Core CT Data Sheet

Документи

datasheet 100/200/600A Medium Split-Core CT Data Sheet
datasheet AVAILABLE CURRENT TRANSFORMERS (DENT CT overview data sheet)

Зафіксовані конфлікти

certifications.standards Review required
UL STD 61010-1, EN 60044-1, CAN/CSA STD C22.2 No. 61010-1 — stored value
['UL STD 61010-1', 'EN 60044-1', 'CAN/CSA STD C22.2 No. 61010-1'] — Conforms to UL STD 61010-1, EN 60044-1, and CAN/CSA STD C22.2 No. 61010-1
Detected during import deep-enrich-2026-09-batch09
electrical.frequency_hz Review required
50-400 — stored value
50 to 400 Hz — 50 to 400 Hz
Detected during import deep-enrich-2026-09-batch09
electrical.measurement_category Review required
CAT III — stored value
Category III — 600 VAC, Category III
Detected during import deep-enrich-2026-09-batch09
electrical.ct_type Review required
split_core — stored value
Split-core — Split-core current transformers provide linear output voltage
Detected during import deep-enrich-2026-09-batch09

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesscomplete
region_notesOne specification; the datasheet cites UL, CAN/CSA and EN conformity together and prints no market variant.