⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Current Transformers (CT)

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category current_transformers
manufacturer Magnelab
model SCT-3000-3000
region GLOBAL
variant —

Electrical

accuracy_class 1.0 (IEC 61869-2) суперечливе
SCT-3000 Split-Core AC Current Sensor Spec Sheet
accuracy_current_range 10% to 130% of rated current
aperture_in 3.0
SCT-3000 Split-Core AC Current Sensor Spec Sheet
core_type Split-core
ct_type split_core
SCT-3000 Split-Core AC Current Sensor Spec Sheet
dielectric_withstand_v 3800
SCT-3000 Split-Core AC Current Sensor Spec Sheet
frequency_hz 30-1000
SCT-3000 Split-Core AC Current Sensor Spec Sheet
lead_conductor_awg 22
lead_configuration Twisted pair
lead_length_m 2.4
SCT-3000 Split-Core AC Current Sensor Spec Sheet
max_system_voltage_v 600
minimum_load_impedance_kohm 75
SCT-3000 Split-Core AC Current Sensor Spec Sheet
output_type Voltage output (0.333 Vac / 333 mV); internal burden resistor, not a mA or 5 A secondary
phase_angle_error_deg <0.2
phase_displacement_deg 0.2
SCT-3000 Split-Core AC Current Sensor Spec Sheet
primary_current_a 3000
SCT-3000 Split-Core AC Current Sensor Spec Sheet
rated_insulation_voltage_v 600
SCT-3000 Split-Core AC Current Sensor Spec Sheet
ratio 3000 A : 0.333 V
SCT-3000 Split-Core AC Current Sensor Spec Sheet
secondary_output 0.333 V AC at rated current
secondary_voltage_mv 333
SCT-3000 Split-Core AC Current Sensor Spec Sheet
secondary_voltage_v 0.333
SCT-3000 Split-Core AC Current Sensor Spec Sheet
warranty_years 10
window_diameter_mm 76.2

Physical / mechanical

dimensions_mm A 146.05, B 190.5, C 30.48, D 76.2, E 127
weight_kg 1.16
SCT-3000 Split-Core AC Current Sensor Spec Sheet

Environment

operating_temperature_max_c 70
SCT-3000 Split-Core AC Current Sensor Spec Sheet
operating_temperature_min_c -20
SCT-3000 Split-Core AC Current Sensor Spec Sheet
operating_temperature_range_c -20 to 70
storage_temperature_range_c -20 to 80

Certifications

certifications UL recognized; UL 61010-1; EN 60044-1; CE; RoHS
standards UL Standard 61010-1, EN 60044-1
SCT-3000 Split-Core AC Current Sensor Spec Sheet

Документи

datasheet SCT-3000 Split-Core AC Current Sensor Spec Sheet
product_page SCT-3000 Split Core Current Transformer

Зафіксовані конфлікти

electrical.accuracy_class Review required
1.0 (IEC 61869-2) — stored value
1.0 per IEC 61869-2 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch07

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesscomplete
region_notesSingle worldwide specification; the spec sheet cites UL Standard 61010-1 and EN 60044-1 together and prints no market-specific variant.