База знань › Current Transformers (CT)
Phoenix Contact PACT RCP-4000A-1A-D95
Official manufacturer GLOBAL перевірено 25 вересня 2026 р.
Identity
| category | current_transformers |
| manufacturer | Phoenix Contact |
| model | PACT RCP-4000A-1A-D95 |
| region | GLOBAL |
| variant | — |
Electrical
| accuracy_class |
0.2 (IEC 61869-10: A1)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| coil_installed_diameter_mm |
95
PACT RCP-4000A-1A-D95 - Current transformer - 2904921
|
| connection_method |
Screw connection, M3, 0.5 Nm ... 0.6 Nm tightening torque
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| ct_secondary_current_a |
1
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| frequency_range_hz |
45 Hz ... 65 Hz (measuring transducer); 40 Hz ... 20000 Hz (measuring coil)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| insulation_voltage |
1000 V AC (rms CAT III); 600 V AC (rms CAT IV)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| manufacturer_part_number |
2904921
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| max_secondary_cable_distance |
up to 55 m (2.5 mm2) copper cable
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| measuring_coil_inner_diameter_mm |
95
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| measuring_coil_insulation |
1000 V AC (rms CAT III); 600 V AC (rms CAT IV)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| measuring_coil_test_voltage |
10.45 kV DC (60 s)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| primary_current_range_a |
0 A AC ... 100 A AC through 0 A AC ... 4000 A AC (eight selectable ranges)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| primary_rated_current_a |
0 A AC ... 100 A AC; 0 A AC ... 250 A AC; 0 A AC ... 400 A AC; 0 A AC ... 630 A AC; 0 A AC ... 1000 A AC; 0 A AC ... 1500 A AC; 0 A AC ... 2000 A AC; 0 A AC ... 4000 A AC (configurable via DIP switches)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| rated_frequency_hz |
45 Hz ... 65 Hz
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| rated_power_va |
1.25
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| secondary_rated_current_a |
0 A AC ... 1 A AC
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| sensor_type |
Rogowski coil with 1 A measuring transducer (split / openable coil, closes around the conductor)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921
|
| signal_line_length_m |
3
PACT RCP-4000A-1A-D95 - Current transformer - 2904921
|
| supported_ct_ratios |
Eight selectable primary ranges from 0-100 A AC to 0-4000 A AC, all against a 0-1 A AC output
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| transducer_test_voltage |
1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| weight_g |
419
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
Physical / mechanical
| coil_length_mm |
300
PACT RCP-4000A-1A-D95 - Current transformer - 2904921
|
| dimensions_mm |
{'width': 22.5, 'height': 85, 'depth': 70.4}
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
Environment
| ambient_temperature_coil_c |
-30 ... 80
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| ambient_temperature_transducer_c |
-20 ... 70
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| operating_temperature_c |
-30 ... 80 (measuring coil); -20 ... 70 (measuring transducer)
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
Interfaces & connectors
| documented_ports | [{'port_role': 'CT', 'port_label_from_manual': 'Rogowski coil signal line to measuring transducer', 'port_type': 'signal line', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': 'Technical data', 'quote': 'Cable Length: "3 m" signal line; maximum copper cable distances up to "55 m (2.5 mm2)"'}] суперечливе |
Protection
| degree_of_protection |
Measuring coil: IP54; Measuring transducer: IP20
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
Certifications
| standards |
IEC 61010-1, IEC 61869-10, EN 61000-6-3, EN 61000-6-4
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
| standards_approvals |
CE, CMIM, UL 61010, UL 508, IEC 61010-1, IEC 61869-10
PACT RCP-4000A-1A-D95 - Current transformer - 2904921 (data sheet, PDF export of the product page)
|
Документи
Зафіксовані конфлікти
interfaces.documented_ports Review required
[{'port_role': 'CT', 'port_label_from_manual': 'Rogowski coil signal line to measuring transducer', 'port_type': 'signal line', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': 'Technical data', 'quote': 'Cable Length: "3 m" signal line; maximum copper cable distances up to "55 m (2.5 mm2)"'}] — stored value
[{'port_role': 'CT', 'port_label_from_manual': 'Measuring coil', 'port_type': 'Rogowski split-core coil, 95 mm window', 'direction': 'input', 'electrical_domain': 'ac', 'document': 0, 'page': 'Technical data', 'quote': 'Window Size (Measuring Coil Diameter) 95 mm'}, {'port_role': 'METER', 'port_label_from_manual': 'Measuring transducer secondary output', 'port_type': '1 A AC secondary', 'direction': 'output', 'electrical_domain': 'ac', 'document': 0, 'page': 'Technical data', 'quote': 'Secondary Rated Current 0 A AC ... 1 A AC'}] — incoming package
Detected during import deep-enrich-2026-09-batch10
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | One worldwide specification; the data sheet cites IEC 61010-1, IEC 61869-10 and EN 61000-6-3/-6-4 with no market-specific variant. |