⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Data Loggers

Official manufacturer EU перевірено 25 вересня 2026 р.

Identity

category data_loggers
manufacturer SMA
model EDML-10
region EU
variant —

Electrical

active_power_control True
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
active_power_control_range 0-100% of total system power
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
digital_input_count 4
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
digital_input_range 0 V DC to 30 V DC
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
digital_output_count 4
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
digital_output_range 0 V DC to 30 V DC
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
ethernet_port_count 2
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
ethernet_speed 10/100/1000 Mbps (RJ45)
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
export_control True
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
fanless True
Data Manager L
max_connected_devices 200
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
max_connected_inverters 200
Data Manager L
max_ethernet_modbus_tcp_devices 10
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
max_operating_altitude_m 3000
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
power_consumption_w 18
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
power_supply 9 V DC to 36 V DC, typ. 24 V DC
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
reactive_power_control Q(V) characteristic curve, as a percentage of maximum AC power
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
relative_humidity 5% to 95% (non-condensing)
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
supply_voltage 9 to 36 VDC, typ. 24 VDC
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
supply_voltage_max_v 36
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
supply_voltage_min_v 9
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
supply_voltage_typical_v 24
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
supported_device_types ['PV inverter', 'Battery inverter', 'Energy meter / power analyzer', 'External I/O system', 'External, directly communicating sensor', 'Weather station', 'Charging points', 'Subordinate Data Manager', 'SMA Hybrid Controller']
Data Manager L
usb_port_count 3
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
usb_ports 1 x USB 3.0, type A; 2 x USB 2.0, type A
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
weight_g 940
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
zero_export True
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13

Physical / mechanical

depth_mm 48.8
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
dimensions_mm {'width': 150, 'height': 120.2, 'depth': 48.8}
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
height_mm 120.2
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
weight_kg 0.94
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
width_mm 150
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15

Installation

mounting Top-hat rail mounting / wall mounting
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13

Environment

ip_rating IP20
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
operating_temperature_max_c 70
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
operating_temperature_min_c -40
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15

Interfaces & connectors

direct_marketing_interface True
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
documented_ports [{'port_role': 'ETHERNET', 'port_label_from_manual': 'Network (LAN)', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '2 x 10/100/1000 Mbps (RJ45)'}, {'port_role': 'RS232', 'port_label_from_manual': 'Serial interface', 'port_type': 'D-Sub 9', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '1 x RS-232, D-Sub 9'}, {'port_role': 'USB', 'port_label_from_manual': 'USB', 'port_type': 'USB type A', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 3, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '1 x USB 3.0, 2 x USB 2.0 (type A)'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital inputs', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '4 x DI, 0 to 30 VDC'}] суперечливе
protocols ['SMA Data2+', 'Modbus TCP', 'Modbus RTU', 'SunSpec', 'FTP push'] суперечливе
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
rs232 True
SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
serial_interface 1 x RS232, D-sub
Operating manual SMA DATA MANAGER L EDML-10-BE-en-13

Документи

datasheet SMA DATA MANAGER L - datasheet EDML-10-DS-en-15
product_page Data Manager L
user_manual Operating manual SMA DATA MANAGER L EDML-10-BE-en-13
user_manual SMA DATA MANAGER L eManual

Зафіксовані конфлікти

interfaces.documented_ports Review required
[{'port_role': 'ETHERNET', 'port_label_from_manual': 'Network (LAN)', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '2 x 10/100/1000 Mbps (RJ45)'}, {'port_role': 'RS232', 'port_label_from_manual': 'Serial interface', 'port_type': 'D-Sub 9', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '1 x RS-232, D-Sub 9'}, {'port_role': 'USB', 'port_label_from_manual': 'USB', 'port_type': 'USB type A', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 3, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '1 x USB 3.0, 2 x USB 2.0 (type A)'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital inputs', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 1, 'page': 'EDML-10 datasheet, Connections', 'quote': '4 x DI, 0 to 30 VDC'}] — stored value
[{'port_role': 'ETHERNET', 'port_label_from_manual': 'LAN1', 'port_type': 'RJ45 10/100/1000 Mbps', 'direction': 'bidirectional', 'electrical_domain': 'COMMUNICATION', 'notes': 'Internal node communication, preconfigured 172.16.1.22', 'document': 0, 'page': 'Connector overview', 'quote': 'LAN1 (Internal network, RJ45)'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'LAN2', 'port_type': 'RJ45 10/100/1000 Mbps', 'direction': 'bidirectional', 'electrical_domain': 'COMMUNICATION', 'notes': 'External node communication, preconfigured 192.168.100.22', 'document': 0, 'page': 'Connector overview', 'quote': 'LAN2 (External network, RJ45)'}, {'port_role': 'RS232', 'port_label_from_manual': 'P1 RS-232/422/485', 'port_type': 'D-sub serial interface', 'direction': 'bidirectional', 'electrical_domain': 'COMMUNICATION', 'document': 0, 'page': 'Technical Data — serial interfaces', 'quote': '1 x RS232, D-sub'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DI', 'port_type': '5-pole terminal block, 0 V DC to 30 V DC', 'direction': 'input', 'electrical_domain': 'SIGNAL', 'count': 4, 'document': 0, 'page': 'Technical Data — digital inputs', 'quote': '4 x DI, 0 V DC to 30 V DC'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'DO', 'port_type': '5-pole terminal block, 0 V DC to 30 V DC', 'direction': 'output', 'electrical_domain': 'SIGNAL', 'count': 4, 'document': 0, 'page': 'Technical Data — digital outputs', 'quote': '4 x DO, 0 V DC to 30 V DC'}, {'port_role': 'USB', 'port_label_from_manual': 'USB 3.0 / USB 2.0 type A', 'port_type': 'USB type A', 'direction': 'bidirectional', 'electrical_domain': 'COMMUNICATION', 'count': 3, 'document': 0, 'page': 'Technical Data — USB', 'quote': '1 x USB 3.0, type A; 2 x USB 2.0, type A'}] — incoming package
Detected during import deep-enrich-2026-09-batch11
interfaces.protocols Review required
['SMA Data2+', 'Modbus TCP', 'Modbus RTU', 'SunSpec', 'FTP push'] — stored value
['SMA Speedwire', 'Modbus TCP', 'Modbus RTU (via RS232-to-RS485 adapter)', 'SunSpec Modbus', 'Sunny Portal powered by ennexOS'] — SMA Speedwire, Modbus TCP, Modbus RTU (via RS232-RS485 adapter), SunSpec Modbus profiles, Sunny Portal (ennexOS)
Detected during import deep-enrich-2026-09-batch11

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesExisting ANMA region retained verbatim; not changed.
withheld:cloud_requiredfalse
withheld:local_web_uitrue