⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Dc Distribution

Official manufacturer Global (12/24/48V DC systems) перевірено 25 вересня 2026 р.

Identity

category dc_distribution
manufacturer Victron Energy B.V. суперечливе
model Lynx Power In
product_family Lynx Distribution System
product_status active
product_status_evidence Listed as a current product in the DC distribution systems category on victronenergy.com.
region Global (12/24/48V DC systems)
sku LYN020102000
sku_note Observed in product-image filenames on the official Victron product page and understood there to designate the M8 version; no order-code table was found in the manual, so this code is recorded as observed rather than as a confirmed catalogue entry. The M10 version's code is UNKNOWN.
variants M8 and M10 busbar versions; the manual publishes a single shared specification table for both.

Electrical

continuous_current_rating 1000Adc continuous
current_rating_statement 'The Lynx Distributor, Lynx Shunt VE.Can, Lynx Class-T Power In and the Lynx Power In are rated for a nominal current of 1000A for 12, 24 or 48 System voltages.'
reverse_polarity_protection —
self_consumption None - passive module with no electronics
voltage_range 9 - 60Vdc

Physical / mechanical

busbar_dimensions_hxw 8 x 30mm
busbar_material Tinned copper
dimensions_hxwxd 290 x 170 x 80 mm
enclosure_material ABS
protection_class IP22
weight 2.1 kg

Installation

bolt_torque —
busbar_connection M8 or M10 (version dependent); fuse and cable connections remain M8 on both versions
fuse_positions None - the Lynx Power In has no fuse positions (fusing is provided by the Lynx Distributor, Lynx Shunt VE.Can or Lynx Class-T Power In)
number_of_connections 'The Lynx Power In contains a positive and negative busbar with 4 connections for batteries, loads or chargers and a ground connection.'
number_of_dc_connections 4 per busbar, plus a ground connection

Environment

humidity Max. 95% (non-condensing)
operating_temperature_range -40°C to +60°C
storage_temperature_range -40°C to +60°C

Interfaces & connectors

monitoring None - passive busbar module with no monitoring, LEDs or communication ports

Protection

note No electronic protection - passive busbar module

Certifications

standards ['UNKNOWN - a Declaration of Conformity PDF covering Lynx DC distribution is published but was not fetched, so no standard is claimed']

Warranty & service

summary 5-year standard warranty and global repair service

Документи

certificate {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Declaration of Conformity - Lynx DC distribution (2023-08-28) — знайдено, не отримано
drawing {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Lynx Power In enclosure dimensions (M10) — знайдено, не отримано
drawing {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Lynx Power In enclosure dimensions (M8) — знайдено, не отримано
manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Lynx Power In Manual (PDF) — знайдено, не отримано
manual Lynx Power In Manual - 2. Introduction
manual {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} Lynx Power In Manual - 5. Installation — знайдено, не отримано
manual Lynx Power In Manual - 8. Technical Specifications
product-page Lynx Power In | Victron Energy
user_manual Lynx Power In manual (EN, HTML)

Зафіксовані конфлікти

identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import wave6-2026-09-batch08
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import system-topology-2026-09-batch04

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Available in two versions with M8 or M10 busbar connections, though fuse and cable connections remain M8M8 or M10 busbar; fuse and cable connections M8
Busbar dimensions (hxw)8 x 30mm
builder_completenesspartial
region_notesANMA's stored region for this record is the sentence 'Global (12/24/48V DC systems)'. It is carried verbatim here so the importer can match the row; the defect is reported in identity_review and is NOT corrected by this record.