Victron Energy Lynx Power In
Official manufacturer Global (12/24/48V DC systems) перевірено 25 вересня 2026 р.
Identity
| category | dc_distribution |
| manufacturer | Victron Energy B.V. суперечливе |
| model | Lynx Power In |
| product_family | Lynx Distribution System |
| product_status | active |
| product_status_evidence | Listed as a current product in the DC distribution systems category on victronenergy.com. |
| region | Global (12/24/48V DC systems) |
| sku | LYN020102000 |
| sku_note | Observed in product-image filenames on the official Victron product page and understood there to designate the M8 version; no order-code table was found in the manual, so this code is recorded as observed rather than as a confirmed catalogue entry. The M10 version's code is UNKNOWN. |
| variants | M8 and M10 busbar versions; the manual publishes a single shared specification table for both. |
Electrical
| continuous_current_rating | 1000Adc continuous |
| current_rating_statement | 'The Lynx Distributor, Lynx Shunt VE.Can, Lynx Class-T Power In and the Lynx Power In are rated for a nominal current of 1000A for 12, 24 or 48 System voltages.' |
| reverse_polarity_protection | — |
| self_consumption | None - passive module with no electronics |
| voltage_range | 9 - 60Vdc |
Physical / mechanical
| busbar_dimensions_hxw | 8 x 30mm |
| busbar_material | Tinned copper |
| dimensions_hxwxd | 290 x 170 x 80 mm |
| enclosure_material | ABS |
| protection_class | IP22 |
| weight | 2.1 kg |
Installation
| bolt_torque | — |
| busbar_connection | M8 or M10 (version dependent); fuse and cable connections remain M8 on both versions |
| fuse_positions | None - the Lynx Power In has no fuse positions (fusing is provided by the Lynx Distributor, Lynx Shunt VE.Can or Lynx Class-T Power In) |
| number_of_connections | 'The Lynx Power In contains a positive and negative busbar with 4 connections for batteries, loads or chargers and a ground connection.' |
| number_of_dc_connections | 4 per busbar, plus a ground connection |
Environment
| humidity | Max. 95% (non-condensing) |
| operating_temperature_range | -40°C to +60°C |
| storage_temperature_range | -40°C to +60°C |
Interfaces & connectors
| monitoring | None - passive busbar module with no monitoring, LEDs or communication ports |
Protection
| note | No electronic protection - passive busbar module |
Certifications
| standards | ['UNKNOWN - a Declaration of Conformity PDF covering Lynx DC distribution is published but was not fetched, so no standard is claimed'] |
Warranty & service
| summary | 5-year standard warranty and global repair service |
Документи
certificate
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Declaration of Conformity - Lynx DC distribution (2023-08-28) — знайдено, не отримано
drawing
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Power In enclosure dimensions (M10) — знайдено, не отримано
drawing
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Power In enclosure dimensions (M8) — знайдено, не отримано
manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Power In Manual (PDF) — знайдено, не отримано
manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
Lynx Power In Manual - 5. Installation — знайдено, не отримано
product-page
Lynx Power In | Victron Energy
user_manual
Lynx Power In manual (EN, HTML)
Зафіксовані конфлікти
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import wave6-2026-09-batch08
identity.manufacturer Review required
Victron Energy B.V. — stored value
Victron Energy — incoming package
Detected during import system-topology-2026-09-batch04
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Available in two versions with M8 or M10 busbar connections, though fuse and cable connections remain M8 | M8 or M10 busbar; fuse and cable connections M8 |
| Busbar dimensions (hxw) | 8 x 30mm |
| builder_completeness | partial |
| region_notes | ANMA's stored region for this record is the sentence 'Global (12/24/48V DC systems)'. It is carried verbatim here so the importer can match the row; the defect is reported in identity_review and is NOT corrected by this record. |