Blink HPC-160-480
Official manufacturer NA перевірено 25 вересня 2026 р.
Identity
| category | ev_chargers |
| manufacturer | Blink |
| model | HPC-160-480 |
| region | — |
Electrical
| ac_input_voltage_v |
480
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| ac_voltage_v |
480
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| breaker_rating_a |
270
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| cable_length_ft |
16
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| cable_length_m |
5
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| cable_lengths_m |
5
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| ccs_cable |
Up to 400A - Liquid Cooled
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| cellular_4g |
True
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| chademo_cable |
Standard up to 125A - Air Cooled || Optional up to 200A - Air Cooled
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| charger_type |
dc_fast
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| connector_types |
['CCS1', 'CHAdeMO', 'NACS']
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| cooling |
Air Cooled
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| cycle_mode |
1 x 160kW (Max : 500A)
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| dc_output_voltage_max_v |
1000
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| dc_output_voltage_min_v |
150
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| dimensions_in_lxdxh |
43.07" x 36.97" x 81.3"
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| dimensions_l_d_h_in |
43.07" x 36.97" x 81.3"
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| display |
10" LCD touch screen
суперечливе
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| external_meter_required |
False
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| full_load_amps_a |
215
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| grid_frequency_hz |
60
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| ik_rating |
IK10
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_ac_input_current_a |
215
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_dc_output_current_a |
500
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_dc_output_power_kw |
160
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_dc_power_kw |
160
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_efficiency_percent |
94
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_output_current_a |
500
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| metering |
DC kWh meter per connector
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| nacs_cable |
Up to 600A – Liquid Cooled
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| ocpp_version |
1.6J
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| parallel_mode |
2 x 80kW (Max: 500A)
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| phase_count |
3
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| power_factor |
> 0.98 @ full load
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| rated_dc_power_kw |
160
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| rated_power_kva |
178.5
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| recommended_breaker_a |
270
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| rfid |
ISO/IEC 14443A/B
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| rfid_reader |
RFID: ISO/IEC 14443A/B || Credit Card Reader
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| vehicle_protocols |
['IEC-61851', 'ISO-15118', 'DIN 70121', 'CHAdeMO 0.9/1.0']
Blink DCFC 160kW specification sheet (HPC-160-480)
|
Physical / mechanical
| weight_kg |
500
Blink DCFC 160kW specification sheet (HPC-160-480)
|
Environment
| humidity |
≤ 95% RH working || ≤ 99% RH storage (Non-condensing)
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| ip_rating |
NEMA 3S (IP54)
суперечливе
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| max_altitude_m |
2000
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| operating_temperature_max_c |
55
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| operating_temperature_min_c |
-20
Blink DCFC 160kW specification sheet (HPC-160-480)
|
Interfaces & connectors
| communications |
['Ethernet', 'WiFi', '4G']
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| documented_ports | [{'port_role': 'AC_IN', 'port_label_from_manual': 'Input Voltage || Frequency', 'port_type': '3-phase AC supply 480VAC (3P + N + PE)', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 215, 'document': 1, 'page': 'Input', 'quote': 'Input Voltage || Frequency 480VAC (3P + N + PE) || 60Hz; FLA || Breaker Rating 215A || 270A (or larger)'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'Connector Options', 'port_type': 'CCS1 / CHAdeMO / NACS charging cable', 'direction': 'output', 'electrical_domain': 'DC', 'max_current_a': 500, 'document': 1, 'page': 'Output', 'quote': 'Max Output Current Up to 500A'}] суперечливе |
| ethernet |
True
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| protocols |
['OCPP 1.6J', 'ISO 15118', 'DIN 70121', 'IEC 61851 Mode 4']
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| wifi |
True
Blink DCFC 160kW specification sheet (HPC-160-480)
|
Protection
| residual_current_protection |
20mA Type A GFCI RCD
Blink DCFC 160kW specification sheet (HPC-160-480)
|
| surge_protection |
20kA
Blink DCFC 160kW specification sheet (HPC-160-480)
|
Certifications
| certifications |
['UL 2202', 'UL 2231-2', 'EN 61000-6-1:2007', 'EN 61000-6-3:2007/A1:2011/AC:2012']
Blink DCFC 160kW specification sheet (HPC-160-480)
|
Документи
installation_manual
Blink DCFC 160kW product manual
product_page
Blink 60kW-360kW DCFC - product page
Зафіксовані конфлікти
interfaces.documented_ports Review required
[{'port_role': 'AC_IN', 'port_label_from_manual': 'Input Voltage || Frequency', 'port_type': '3-phase AC supply 480VAC (3P + N + PE)', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 215, 'document': 1, 'page': 'Input', 'quote': 'Input Voltage || Frequency 480VAC (3P + N + PE) || 60Hz; FLA || Breaker Rating 215A || 270A (or larger)'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'Connector Options', 'port_type': 'CCS1 / CHAdeMO / NACS charging cable', 'direction': 'output', 'electrical_domain': 'DC', 'max_current_a': 500, 'document': 1, 'page': 'Output', 'quote': 'Max Output Current Up to 500A'}] — stored value
[{'port_role': 'AC_IN', 'port_label_from_manual': 'Input Voltage || Frequency', 'port_type': '480VAC (3P + N + PE)', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': "160kW spec sheet, column 'HPC-160-480'", 'quote': '480VAC (3P + N + PE) || 60Hz'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'Connector Options', 'port_type': 'CCS1 / CHAdeMO / NACS tethered cable', 'direction': 'output', 'electrical_domain': 'DC', 'quantity': 2, 'document': 0, 'page': "160kW spec sheet, column 'HPC-160-480'", 'quote': 'CCS1 || CHAdeMO || NACS'}] — incoming package
Detected during import wave6-2026-09-batch08
environment.ip_rating Review required
NEMA 3S (IP54) — stored value
NEMA 3S (IP54), IK 10 — Ingress Protection: NEMA 3S (IP54), IK 10
Detected during import wave6-2026-09-batch08
electrical.display Review required
10" LCD touch screen — stored value
10'' LCD Touch Screen — Display: 10'' LCD Touch Screen
Detected during import wave6-2026-09-batch08
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | North American configuration only: 480 VAC 60 Hz three-phase plus neutral, CCS1/CHAdeMO/NACS, UL 2202 / UL 2231-2, NEMA 3S enclosure. No IEC edition is published on Blink's site. |
| withheld:cellular_4g | true |
| withheld:charging_level | "DC fast charging" |
| withheld:current_type | "DC" |
| withheld:ethernet | true |
| withheld:wifi | true |