Identity

category ev_chargers
manufacturer ChargePoint
model CPF50
region —
variant —

Electrical

ac_voltage_v 240
Datasheet - CPF50
authentication_methods RFID cards; Android Tap-to-Charge; iOS Tap-to-Charge
cable_length_ft [18, 23]
Datasheet - CPF50
cable_length_m [5.4, 7.0] суперечливе
Datasheet - CPF50
circuit_breaker_rating_a 70 A dual pole (non-GFCI); dual-station install uses two independent 70 A breakers
connector_types ['SAE J1772', 'NACS']
Datasheet - CPF50
energy_measurement_accuracy +/- 2% from 2% to full scale (50 A)
humidity_operating_pct Up to 95 @ 50 °C, non-condensing
input_voltage_v 208/240
max_output_current_a 50
Datasheet - CPF50
max_output_power_kw 12
Datasheet - CPF50
number_of_ports [1, 2]
CPF50 AC Level 2 charging station
ocpp_version OCPP 2.0.1
phases 1 (single phase, 3-wire: L1, L2, Earth; no neutral)
power_select_output_current_a_max 48
Datasheet - CPF50
power_select_output_current_a_min 16
Datasheet - CPF50
power_share_supported True
Datasheet - CPF50
rcd_type 20 mA CCID with auto retry
short_circuit_current_rating 5 kA
warranty_years 2

Physical / mechanical

weight_kg 8.2 (wall mount, 18 ft cable); 22.7 (single pedestal, 18 ft); 66.2 (dual pedestal, 23 ft, with cable management)

Installation

mounting ['wall', 'pedestal']
CPF50 AC Level 2 charging station

Environment

ip_rating Type 3R per UL 50E
Datasheet - CPF50
operating_temperature_max_c 50
Datasheet - CPF50
operating_temperature_min_c -40
Datasheet - CPF50
operating_temperature_range_c -40 to 50
storage_temperature_range_c -40 to 60

Interfaces & connectors

communication_protocol Wi-Fi 2.4/5 GHz (802.11 a/b/g/n); 4G LTE or via ChargePoint Gateway
communications ['2.4/5 GHz Wi-Fi (802.11 a/b/g/n)', '4G LTE']
Datasheet - CPF50
documented_ports [{'port_role': 'AC_IN', 'port_label_from_manual': 'Input Power Connection', 'port_type': 'hardwired branch circuit, 3-wire (L1, L2, Earth)', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': "Electrical Input table, row 'One Station - Maximum 50A (Standard)'", 'quote': 'One 70 A branch circuit; 70 A dual pole (non-GFCI); 3-wire (L1, L2, Earth)'}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'Connector Types', 'port_type': 'SAE J1772 / NACS tethered cable', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 2, 'document': 0, 'page': 'Connector Types', 'quote': 'SAE J1772™, NACS'}]
protocols ['OCPP 2.0.1']
Datasheet - CPF50

Protection

protection_degree_ip Type 3R per UL 50E
surge_protection 6 kV @ 3000 A

Certifications

certifications ['UL and C-UL listed', 'UL2594', 'UL2231-1', 'UL2231-2', 'ENERGY STAR']
Datasheet - CPF50

Документи

application_note Site Design Guide - CPF50
datasheet Datasheet - CPF50
product_page CPF50 AC Level 2 charging station

Зафіксовані конфлікти

certifications.certifications Resolved — kept current value
['UL and C-UL listed', 'UL2594', 'UL2231-1', 'UL2231-2', 'ENERGY STAR'] — stored value
UL and C-UL listed; complies with UL 2594, UL 2231-1, UL 2231-2; NEC Article 625; Canada CSA C22.2 No. 280, 281.1, 281.2 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch09
electrical.cable_length_m Review required
[5.4, 7.0] — stored value
5.4 or 7.0 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch09

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesNorth American commercial/fleet AC Level 2 station, 208/240 V AC single phase.
withheld:cellular_4gtrue
withheld:charging_level"AC Level 2"
withheld:current_type"AC"
withheld:energy_startrue
withheld:phase_count1
withheld:wifitrue