ChargePoint CPF50
Official manufacturer NA перевірено 25 вересня 2026 р.
Identity
| category | ev_chargers |
| manufacturer | ChargePoint |
| model | CPF50 |
| region | — |
| variant | — |
Electrical
| ac_voltage_v |
240
Datasheet - CPF50
|
| authentication_methods | RFID cards; Android Tap-to-Charge; iOS Tap-to-Charge |
| cable_length_ft |
[18, 23]
Datasheet - CPF50
|
| cable_length_m |
[5.4, 7.0]
суперечливе
Datasheet - CPF50
|
| circuit_breaker_rating_a | 70 A dual pole (non-GFCI); dual-station install uses two independent 70 A breakers |
| connector_types |
['SAE J1772', 'NACS']
Datasheet - CPF50
|
| energy_measurement_accuracy | +/- 2% from 2% to full scale (50 A) |
| humidity_operating_pct | Up to 95 @ 50 °C, non-condensing |
| input_voltage_v | 208/240 |
| max_output_current_a |
50
Datasheet - CPF50
|
| max_output_power_kw |
12
Datasheet - CPF50
|
| number_of_ports |
[1, 2]
CPF50 AC Level 2 charging station
|
| ocpp_version | OCPP 2.0.1 |
| phases | 1 (single phase, 3-wire: L1, L2, Earth; no neutral) |
| power_select_output_current_a_max |
48
Datasheet - CPF50
|
| power_select_output_current_a_min |
16
Datasheet - CPF50
|
| power_share_supported |
True
Datasheet - CPF50
|
| rcd_type | 20 mA CCID with auto retry |
| short_circuit_current_rating | 5 kA |
| warranty_years | 2 |
Physical / mechanical
| weight_kg | 8.2 (wall mount, 18 ft cable); 22.7 (single pedestal, 18 ft); 66.2 (dual pedestal, 23 ft, with cable management) |
Installation
| mounting |
['wall', 'pedestal']
CPF50 AC Level 2 charging station
|
Environment
| ip_rating |
Type 3R per UL 50E
Datasheet - CPF50
|
| operating_temperature_max_c |
50
Datasheet - CPF50
|
| operating_temperature_min_c |
-40
Datasheet - CPF50
|
| operating_temperature_range_c | -40 to 50 |
| storage_temperature_range_c | -40 to 60 |
Interfaces & connectors
| communication_protocol | Wi-Fi 2.4/5 GHz (802.11 a/b/g/n); 4G LTE or via ChargePoint Gateway |
| communications |
['2.4/5 GHz Wi-Fi (802.11 a/b/g/n)', '4G LTE']
Datasheet - CPF50
|
| documented_ports | [{'port_role': 'AC_IN', 'port_label_from_manual': 'Input Power Connection', 'port_type': 'hardwired branch circuit, 3-wire (L1, L2, Earth)', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': "Electrical Input table, row 'One Station - Maximum 50A (Standard)'", 'quote': 'One 70 A branch circuit; 70 A dual pole (non-GFCI); 3-wire (L1, L2, Earth)'}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'Connector Types', 'port_type': 'SAE J1772 / NACS tethered cable', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 2, 'document': 0, 'page': 'Connector Types', 'quote': 'SAE J1772™, NACS'}] |
| protocols |
['OCPP 2.0.1']
Datasheet - CPF50
|
Protection
| protection_degree_ip | Type 3R per UL 50E |
| surge_protection | 6 kV @ 3000 A |
Certifications
| certifications |
['UL and C-UL listed', 'UL2594', 'UL2231-1', 'UL2231-2', 'ENERGY STAR']
Datasheet - CPF50
|
Документи
application_note
Site Design Guide - CPF50
datasheet
Datasheet - CPF50
product_page
CPF50 AC Level 2 charging station
Зафіксовані конфлікти
certifications.certifications Resolved — kept current value
['UL and C-UL listed', 'UL2594', 'UL2231-1', 'UL2231-2', 'ENERGY STAR'] — stored value
UL and C-UL listed; complies with UL 2594, UL 2231-1, UL 2231-2; NEC Article 625; Canada CSA C22.2 No. 280, 281.1, 281.2 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch09
electrical.cable_length_m Review required
[5.4, 7.0] — stored value
5.4 or 7.0 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch09
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | North American commercial/fleet AC Level 2 station, 208/240 V AC single phase. |
| withheld:cellular_4g | true |
| withheld:charging_level | "AC Level 2" |
| withheld:current_type | "AC" |
| withheld:energy_star | true |
| withheld:phase_count | 1 |
| withheld:wifi | true |