Juice Technology JUICE ULTRA 2 hub
Official manufacturer EU перевірено 25 вересня 2026 р.
Identity
| category | ev_chargers |
| manufacturer | Juice Technology |
| model | JUICE ULTRA 2 hub |
| region | EU |
| variant | — |
Electrical
| ac_charging_power_kw | 22 |
| ac_input_current_a |
488 A or 585 A
JUICE ULTRA 2 Product Sheet EN
|
| ac_input_voltage_v |
400
JUICE ULTRA 2 Product Sheet EN
|
| authentication_methods | RFID: ISO/IEC 14443A, ISO 7816, MIFARE Ultralight, NTAG203, MIFARE Mini, MIFARE Classic 1K, MIFARE Classic 4K, FM11RF08 |
| cable_length_m | 7.1 m with cable retraction system |
| connector_type |
2 x CCS2 (IEC 62196-3); optionally CCS1, CHAdeMO or Type 2 AC socket
JUICE ULTRA 2 Product Sheet EN
|
| dc_output_current |
1 x 500 A or 2 x 480 A
JUICE ULTRA 2 Product Sheet EN
|
| dc_output_voltage_max_v |
920
JUICE ULTRA 2 Product Sheet EN
|
| dc_output_voltage_min_v |
150
JUICE ULTRA 2 Product Sheet EN
|
| efficiency_pct | 94.5 (at >50% output) |
| frequency_hz | 45-65 (or 50/60) |
| ik_rating |
IK10
JUICE ULTRA 2 Product Sheet EN
|
| input_voltage_v | 3 x 400 V (+/-10%) |
| iso15118 |
supported (Plug & Charge)
JUICE ULTRA 2 Product Sheet EN
|
| max_ac_power_kw |
22
JUICE ULTRA 2 Product Sheet EN
|
| max_dc_power_kw |
500
JUICE ULTRA 2 Product Sheet EN
|
| max_output_current_a | 1 x 500 A or 2 x 480 A |
| number_of_connectors | 2 |
| ocpp_version |
['OCPP 1.5', 'OCPP 1.6', 'OCPP 2.0 (ready)']
JUICE ULTRA 2 Product Sheet EN
|
| output_voltage_range_v | 150-920 |
| phases | 3 |
| plug_and_charge |
True
JUICE ULTRA 2 Product Sheet EN
|
| rated_power_kw | 500 |
| rcd_type | AC side Type B RCD; DC side short-circuit, overcurrent, over/under-voltage, insulation and earth monitoring |
| rfid |
True
JUICE ULTRA 2 Product Sheet EN
|
Physical / mechanical
| dimensions_mm | Terminal 590 x 1900 x 300; Hub 853 x 2079 x 840 |
Environment
| ip_rating |
IP54
JUICE ULTRA 2 Product Sheet EN
|
| operating_temperature_max_c |
45
JUICE ULTRA 2 Product Sheet EN
|
| operating_temperature_min_c |
-20
JUICE ULTRA 2 Product Sheet EN
|
| operating_temperature_range_c | -20 to +45 |
Interfaces & connectors
| communication_protocol | Ethernet port, GPRS, UMTS, LTE; DIN 70121, ISO 15118 |
Protection
| impact_protection_ik | IK10 |
| protection_degree_ip | IP54 |
Certifications
| certifications | EN 61851-1, EN 61851-22, EN 61851-23, EN 62479, EN 55011+A1, EN 61000-6-1/-2/-3/-4 |
Документи
datasheet
JUICE ULTRA 2 Product Sheet EN
product_page
JUICE ULTRA 2
user_manual
JUICE ULTRA 2 Manual DE/EN
Зафіксовані конфлікти
electrical.ocpp_version Resolved — kept current value
['OCPP 1.5', 'OCPP 1.6', 'OCPP 2.0 (ready)'] — stored value
OCPP 1.5, OCPP 1.6, OCPP 2.0 (ready), JSON/SOAP — incoming package
Detected during import deep-enrich-pass2-2026-09-batch14
electrical.connector_type Resolved — kept current value
2 x CCS2 (IEC 62196-3); optionally CCS1, CHAdeMO or Type 2 AC socket — stored value
2 x CCS2 (IEC 62196-3); on request CCS1 or CHAdeMO, and additional AC Type 2 socket — incoming package
Detected during import deep-enrich-pass2-2026-09-batch14
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | European/Swiss market; 230 V 1-phase / 400 V 3-phase 50 Hz. Juice Technology AG, Switzerland. |
| withheld:current_type | "DC" |