Tritium FLEX HUB Power Cabinet
Official manufacturer GLOBAL перевірено 23 вересня 2026 р.
Identity
| category | ev_chargers |
| manufacturer | Tritium |
| model | FLEX HUB Power Cabinet |
| region | GLOBAL |
| variant | — |
Electrical
| ac_frequency_hz | 50 +/-10% or 60 +/-10% |
| ac_input_voltage_range |
+10% / -15%
TRI-FLEX datasheet
|
| ac_input_voltage_v |
[400, 480]
TRI-FLEX datasheet
|
| altitude_max_m | 3000 |
| cellular_4g |
True
TRI-FLEX datasheet
|
| charger_type |
dc_fast_power_cabinet
TRI-FLEX datasheet
|
| communication_interfaces | Ethernet or cellular SIM 4G/LTE; local load management via Modbus TCP |
| cooling_method | Liquid-cooled power electronics |
| dynamic_load_management |
True
TRI-FLEX datasheet
|
| earthing_systems |
TT, TN-C-S, TN-S, TN-C, IT
TRI-FLEX datasheet
|
| efficiency_pct | 97.2 |
| grid_frequency_hz |
[50, 60]
TRI-FLEX datasheet
|
| input_voltage_v | 400 VAC 3ph +10%/-15% or 480 VAC 3ph +10%/-15% |
| max_efficiency_percent |
97.2
TRI-FLEX datasheet
|
| max_input_current_a | 400 V AC 1260 A / 480 V AC 1050 A (400-800 kW); 400 V AC 2520 A / 480 V AC 2100 A (1000-1600 kW) |
| noise_level_db | <= 65 dB(A) at 1 m, full power 25 degC; quiet mode <= 55 dB(A) |
| ocpp_version |
1.6J (2.0.1 ready)
суперечливе
TRI-FLEX datasheet
|
| overvoltage_category | Category III |
| phases | 3 |
| power_factor_range | 0.0 lagging to 0.0 leading |
| reactive_power_support |
0.0 lagging to 0.0 leading
TRI-FLEX datasheet
|
| short_circuit_current_rating_ka | 65 |
| thd_pct | < 5 |
| thd_percent |
5
TRI-FLEX datasheet
|
Physical / mechanical
| depth_mm |
1225
TRI-FLEX datasheet
|
| dimensions_mm | Height 2250 (2450 with plinth); depth 1225; width 1326 / 2652 / 3978 depending on grid connection |
| height_mm |
2250
TRI-FLEX datasheet
|
| weight_kg | 1720 to 5120 depending on configuration |
Environment
| ip_rating |
IP65
TRI-FLEX datasheet
|
| operating_temperature_range_c | -35 to +55 |
| storage_temperature_range_c | -40 to +60 |
Interfaces & connectors
| documented_ports | [{'port_role': 'AC_IN', 'port_label_from_manual': 'Grid Voltage', 'port_type': '3-phase AC supply', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 1, 'page': 'Power Cabinet', 'quote': 'Grid Voltage 400VAC 3ph +10%/-15% | 480VAC 3ph +10%/-15%'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'DC circuits from Power Cabinet', 'port_type': 'DC circuit to TRI-FLEX dispenser', 'direction': 'output', 'electrical_domain': 'DC', 'document': 1, 'page': 'Power Cabinet', 'quote': 'Local load management interface MODBUS TCP'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'Network Communications', 'port_type': 'Ethernet', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Power Cabinet', 'quote': 'Network Communications Ethernet or Cellular SIM 4G/LTE'}] |
| ethernet |
True
TRI-FLEX datasheet
|
| modbus |
True
TRI-FLEX datasheet
|
Protection
| impact_protection_ik | IK10 |
| protection_degree_ip | IP65, NEMA Type 3R enclosure |
| surge_protection | Type 1+2 SPD |
Certifications
| certifications | CE; UL/CSA; MID; RoHS; WEEE; ISO 27001 |
Документи
application_note
TRI-FLEX brochure
datasheet
TRI-FLEX datasheet
product_page
TRI-FLEX - product page
Зафіксовані конфлікти
electrical.ocpp_version Review required
1.6J (2.0.1 ready) — stored value
1.6J; OCPP 2.0.1 ready — incoming package
Detected during import deep-enrich-pass2-2026-09-batch16
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | The cabinet is published with both 400 VAC/50 Hz and 480 VAC/60 Hz inputs under the same designation, so GLOBAL is correct here. |