⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Gateways / Data Loggers

Phoenix Contact GW MODBUS TCP/RTU 1E/2DB9

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category gateways
manufacturer Phoenix Contact
model GW MODBUS TCP/RTU 1E/2DB9
region GLOBAL
variant —

Electrical

altitude_max_m < 2000
article_number 2702765
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
current_consumption_max 85 mA (24 V DC)
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
current_consumption_typical 76 mA (24 V DC)
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
electrical_isolation IEC UL 61010-1 (VCC // Ethernet)
Phoenix Contact generated datasheet, GW MODBUS TCP/RTU 1E/2DB9 (item 2702765) — Technical data > Electrical properties, row 'Electrical isolation'
ethernet_max_cable_length_m 100 (shielded twisted pair)
ethernet_ports 1
ethernet_speed 10/100 Mbps, auto negotiation суперечливе
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
housing_material PA 6.6, light grey RAL 7035
humidity_pct 10-95 operation, non-condensing
input_current_a 76 mA typical, 85 mA max (24 V DC)
input_voltage_v 10.8 to 30
management Web-based management
Phoenix Contact generated datasheet, GW MODBUS TCP/RTU 1E/2DB9 (item 2702765) — Technical data, row 'Management'
max_modbus_tcp_clients 96
mtbf 69.4 years (25 C) / 46.3 years (40 C), Telcordia, 50 % stress
power_consumption_w 2.04
rs485_port_count 2
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
serial_baud_rates 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 kbps
serial_baudrate 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
serial_connector D-SUB 9 plug
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
serial_data_format 5/6/7/8 data bits; 1/2 stop bits; parity none/even/odd/mark/space
serial_max_cable_length_m 1200
serial_port_count 2
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
serial_ports 2 x D-SUB 9 (Modbus RTU / Modbus ASCII serial)
supply_voltage_max_v 30
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
supply_voltage_min_v 10.8
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
supported_protocols Modbus/RTU, Modbus ASCII, Modbus/TCP; auxiliary ARP, DHCP client, PING

Physical / mechanical

dimensions_mm 22.5 x 99 x 115 (W x H x D)
height_mm 99
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
length_mm 115
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
weight_kg 0.1794
width_mm 22.5
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)

Installation

mounting DIN rail mounting
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)

Environment

ip_rating IP20
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
operating_temperature_max_c 70
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
operating_temperature_min_c -40
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
operating_temperature_range_c -40 to +70
storage_temperature_range_c -40 to +80

Interfaces & connectors

documented_ports [{'port_role': 'RS485', 'port_label_from_manual': 'serial ports', 'port_type': 'D-SUB 9 plug', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': "Technical data list, rows 'Number of serial ports' and 'Connection method'", 'quote': 'Number of serial ports: 2; D-SUB 9 plug'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet ports', 'port_type': '10/100 Mbps, auto negotiation', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': "Technical data list, row 'Number of Ethernet ports'", 'quote': 'Number of Ethernet ports: 1'}]
ethernet True
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
protocols ['Modbus RTU', 'Modbus ASCII', 'Modbus TCP']
GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
test_voltage_data_interface_data_interface 1.5 kVrms (50 Hz, 1 min.)
Phoenix Contact generated datasheet, GW MODBUS TCP/RTU 1E/2DB9 (item 2702765) — Technical data > Electrical properties, row 'Test voltage data interface/data interface'
test_voltage_data_interface_power_supply 1.5 kVrms (50 Hz, 1 min.)
Phoenix Contact generated datasheet, GW MODBUS TCP/RTU 1E/2DB9 (item 2702765) — Technical data > Electrical properties, row 'Test voltage data interface/power supply (50 Hz, 1 min.)'
web_server yes
Phoenix Contact generated datasheet, GW MODBUS TCP/RTU 1E/2DB9 (item 2702765) — Technical data, row 'Web server'

Protection

protection_degree_ip IP20

Certifications

certifications CE; UL 61010-1; cULus; UL Class I Division 2 Groups A/B/C/D T4A; ATEX DEMKO 18ATEX 2026X (II 3 G Ex ec IIC T4 Gc); IECEx UL 18.0023X (Ex ec IIC T4 Gc); EN 61000-6-2 immunity, EN 61000-6-4 emission; EU RoHS

Документи

datasheet GW MODBUS TCP/RTU 1E/2DB9 technical data (article 2702765, PDF export)
manufacturer-document Phoenix Contact generated datasheet, GW MODBUS TCP/RTU 1E/2DB9 (item 2702765)
product_page GW MODBUS TCP/RTU 1E/2DB9 - Interface converters - 2702765

Зафіксовані конфлікти

electrical.ethernet_speed Review required
10/100 Mbps, auto negotiation — stored value
10/100 Mbps, auto-negotiation — incoming package
Detected during import deep-enrich-pass2-2026-09-batch09

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesPhoenix Contact publishes one article number worldwide; ANMA's stored region GLOBAL is carried verbatim.
withheld:serial_transmission_length_m15