Electrical
| analog_input_count |
4
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| analog_output_count |
4
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| device_type |
energy-management gateway / data manager (ennexOS)
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| digital_input_count |
10
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| ethernet_port_count |
3
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| local_api_available |
Modbus/TCP server and client; no other local API named in the datasheet
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| local_modbus_available |
True
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_battery_inverters |
50
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_charging_points |
50
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_connected_devices |
50
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_inverters |
50
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_meters |
50
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_pv_inverters_via_modbus_sunspec |
50
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_system_power_battery_inverters |
7.5 MVA (open-loop control or monitoring)
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| max_system_power_pv_inverters |
2.5 MVA (closed-loop control)
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| physical_interfaces |
['Ethernet (RJ45)', 'RS485', 'Wi-Fi access point', 'digital inputs', 'relay outputs', 'analog inputs', 'analog outputs', 'PT100 temperature inputs']
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| power_consumption_w |
typically 8
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| relay_output_count |
5
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| rs485_port_count |
2
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| supply_voltage_v |
10 V to 30 V DC (external power supply unit, accessory)
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| usb_port_count |
0
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| weight_g |
372
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
Physical / mechanical
| dimensions_mm |
216 (W) x 90 (H) x 68 (D)
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
Installation
| mounting |
Top-hat rail mounting / wall mounting, indoors
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
Environment
| operating_temperature_c |
-20 to +60
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| temperature_input_count |
2
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
Interfaces & connectors
| documented_ports | [{'port_role': 'ETHERNET', 'port_label_from_manual': 'Network (LAN)', 'port_type': 'RJ45 10BaseT/100BaseT', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 3, 'document': 0, 'page': 'Connections', 'quote': 'Network (LAN): 3x RJ45 (1x internet, 2x system network) 10BaseT/100BaseT'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': '6-pole MINI COMBICON', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Connections', 'quote': 'RS485: 2x 6-pole connection, MINI COMBICON'}, {'port_role': 'WIFI', 'port_label_from_manual': 'Wi-Fi access point', 'port_type': 'integrated radio', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Connections', 'quote': 'Wi-Fi access point: ●'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'digital in', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 10, 'document': 0, 'page': 'Connections', 'quote': 'Additional connections: 10x digital in, 1x fast stop, 5x multifunction relay, 4x analog in, 4x analog out, 2x temperature, 1x reset button'}, {'port_role': 'RELAY', 'port_label_from_manual': 'multifunction relay', 'port_type': 'terminal', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 5, 'document': 0, 'page': 'Connections', 'quote': 'Additional connections: 10x digital in, 1x fast stop, 5x multifunction relay, 4x analog in, 4x analog out, 2x temperature, 1x reset button'}, {'port_role': 'ANALOG_IN', 'port_label_from_manual': 'analog in', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 0, 'page': 'Connections', 'quote': 'Additional connections: 10x digital in, 1x fast stop, 5x multifunction relay, 4x analog in, 4x analog out, 2x temperature, 1x reset button'}, {'port_role': 'TEMPERATURE_SENSOR', 'port_label_from_manual': 'temperature', 'port_type': 'terminal (PT100)', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Connections', 'quote': 'Additional connections: 10x digital in, 1x fast stop, 5x multifunction relay, 4x analog in, 4x analog out, 2x temperature, 1x reset button'}, {'port_role': 'DC_IN', 'port_label_from_manual': 'Voltage supply', 'port_type': '2-pin MINI COMBICON', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'document': 0, 'page': 'Connections', 'quote': 'Voltage supply: 2-pin connection, MINI COMBICON'}] |
| local_web_ui |
True
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| protocols |
['Modbus/RTU', 'Modbus/TCP', 'Modbus/TCP SunSpec', 'FTP push', 'EtherLynx']
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
| wifi |
True
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
Protection
| ingress_protection |
IP20 (NEMA 1)
SMA DATA MANAGER M - EDMM-20 datasheet (EDMM-20-DS-en-10)
|
Документи
product_page
SMA Data Manager M (EDMM-20) product page
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | complete |