⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Gateways / Data Loggers

Official manufacturer EU перевірено 25 вересня 2026 р.

Identity

category gateways
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'Automatic update of the Sunny Home Manager and of subordinate SMA devices is listed as a standard feature.'}
generation HM-20
manufacturer SMA
market_version EU
model HM-20 (Sunny Home Manager 2.0)
mpn —
product_family Sunny Home Manager
product_status active
region EU
release_year —
series Sunny Home Manager 2.0
sku —

Electrical

ac_connection —
ac_voltage_range —
battery_type Not applicable - energy manager / communication gateway
eps_peak_power —
eps_phase —
eps_rated_power_va —
eps_switchover_time_ms —
eps_voltage —
european_efficiency_pct —
external_transfer_switch_required —
frequency_range_hz —
max_ac_current_a 63 A limiting current per phase (above 63 A via external current transformers)
max_apparent_power_va —
max_dc_input_power_w —
max_dc_voltage_v —
max_efficiency_pct —
measurement_accuracy_pct <= 1 %
night_self_consumption_w —
nominal_ac_voltage 110 V / 230 V / 400 V
nominal_current_a 5
nominal_frequency_hz 50 Hz / 60 Hz
number_of_mppt —
parallel_capability —
phase_count 3
power_factor_range —
rated_ac_power_w —
thd_pct —

Physical / mechanical

ac_terminal —
cooling —
dc_connector —
depth_mm 65
dimensions_mm 70 x 88 x 65
display LED on the device; SMA Sunny Portal and SMA Energy App for visualisation
enclosure_material —
height_mm 88
mounting Rail mounting in a switch cabinet or meter cabinet
noise_db —
weight_kg —
width_mm 70

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection —
max_altitude_m —
operating_temperature_c —
pollution_degree —
protective_class —
relative_humidity_pct —
storage_temperature_c —

Interfaces & connectors

app SMA Energy App
communication ['Ethernet']
dry_contact —
meter_interface SMA Energy Meter interface (a separate SMA Energy Meter is required to include third-party inverters)
monitoring_portal SMA Sunny Portal
protocols ['SMA Energy Meter interface', 'SEMP (Simple Energy Management Protocol)', 'EEBUS']

Protection

anti_islanding —
arc_fault —
dc_switch —
insulation_monitoring —
overvoltage_category —
rcmu —
reverse_polarity —
surge_protection_ac —
surge_protection_dc —

Warranty & service

conditions —
extension_options —
standard_years 2

Документи

datasheet SUNNY HOME MANAGER 2.0 datasheet rev HM-20-DS-en-50
manual Operating manual Sunny Home Manager 2.0 (HM-20) - eManual
product_page SMA Sunny Home Manager 2.0 product page

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Compatible device classesSMA PV inverters and battery systems; third-party inverters via separate SMA Energy Meter; Smart Home radio-controlled socket; dishwashers / clothes dryers / washing machines; heat pumps / heating rods / universal heating solution; EV charging stations
Dynamic active power controlas percentage / as value / external specification / zero export - all standard
Forecast-based battery charging / load controlStandard / standard
Heat pumps via SG-Ready interface: internal / externalinternal: not available; external: standard
Interfaces: Wi-Fi / EthernetWi-Fi: not available; Ethernet: standard
Manual / dynamic electricity tariffsManual: standard; dynamic: not available
Max. no. of devices: measurable / measurable and controllable24 / 12
Operation and visualizationSMA Sunny Portal, SMA Energy App, local device LED
Peak Load ShavingStandard
Selectable forecast period24 h / 48 h
Time window control for charging battery-storage systemStandard
builder_completenesspartial