⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Gateways / Data Loggers

Official manufacturer GLOBAL перевірено 23 вересня 2026 р.

Identity

category gateways
manufacturer SMA
model PPC-10
region GLOBAL
variant —

Electrical

active_power_control True
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
altitude_max_m 4000 (2000 with I/O expansion)
analog_input_range 4 mA to 20 mA, -10 V to +10 V
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
analog_inputs 4-20 mA, -10 V to +10 V
analog_output_range 4 mA to 20 mA
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
analog_outputs 4-20 mA
controller_type High-performance PLC (redundant configuration)
current_consumption_a 2 x 1.2 A at 120 VAC / 2 x 0.6 A at 230 VAC; 2 x 2.75 A at 48 VDC / 2 x 5.5 A at 24 VDC
digital_input_voltage 24 V DC
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
digital_inputs 24 V DC
digital_output_rating 250 V AC or 30 V DC, 5 A
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
digital_outputs Relay, 250 V AC or 30 V DC, 5 A
ethernet_port_count 2
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
ethernet_ports 2 separate Ethernet ports with integrated switches, 10BASE-T / 100BASE-T(X)
input_voltage_v 100-240 VAC 50/60 Hz, or 24 VDC, or 36-60 VDC
plant_level_control True
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
pre_fuse_a 16
reactive_power_control True
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
relative_humidity_pct 10-95 non-condensing
serial_ports UNKNOWN - not printed
supply_voltage 100 VAC to 240 VAC, 50 Hz / 60 Hz / 24 VDC / 36 VDC to 60 VDC
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
supported_protocols Modbus/TCP, Modbus/UDP, FTP server; optional IEC 61850, IEC 60870-5-101/-104, DNP3

Physical / mechanical

depth_mm 325
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
dimensions_mm 720 x 1125 x 325 (cabinet)
height_mm 1125
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
weight_kg 60
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
width_mm 720
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)

Installation

mounting Wall mounting

Environment

ip_rating IP54
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
operating_temperature_max_c 50
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
operating_temperature_min_c -20
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
operating_temperature_range_c -20 to +50

Interfaces & connectors

documented_ports [{'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet ports with integrated switches', 'port_type': 'Ethernet', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'PPC-10 datasheet, Communication', 'quote': '2 separate Ethernet ports with integrated switches for external communication; 10 BASE-T and 100 BASE-T(X)'}]
protocols ['Modbus / TCP', 'Modbus / UDP', 'FTP server', 'IEC 61850 (optional)', 'IEC 60 870-5-101/ -104 (optional)', 'DNP 3 (optional)']
POWER PLANT CONTROLLER - PPC-10 datasheet (EN)

Protection

protection_degree_ip IP54

Certifications

certifications CE, EN 60950-1, FCC, NRCS (SANS IEC 60950)

Документи

datasheet POWER PLANT CONTROLLER - PPC-10 datasheet (EN)
user_manual POWER PLANT CONTROLLER PPC-A5-BE-en-23 operating manual

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesSMA publishes one worldwide datasheet for the Power Plant Controller; supply-voltage options cover 100-240 VAC and 24/36-60 VDC.