Identity
| category | gateways |
| manufacturer | Solplanet |
| model | Ai-AMU 2000 |
| region | GLOBAL |
| variant | — |
Electrical
| abus_input_voltage_v |
380-800 V, 3-phase
Datasheet Ai-AMU 2000 EN V6
|
| abus_port_count |
2
Datasheet Ai-AMU 2000 EN V6
|
| ac_frequency_hz |
50/60
Datasheet Ai-AMU 2000 EN V6
|
| ac_input_voltage_v |
100-240 V, L/N (L)+PE
Datasheet Ai-AMU 2000 EN V6
|
| analog_input_count |
4
Datasheet Ai-AMU 2000 EN V6
|
| anti_pid_input_voltage_v |
380-800 V, 3-phase+FE
Datasheet Ai-AMU 2000 EN V6
|
| anti_pid_module_count |
2
Datasheet Ai-AMU 2000 EN V6
|
| anti_pid_output_voltage_v |
0/+/-750 V
Datasheet Ai-AMU 2000 EN V6
|
| digital_input_count |
4
Datasheet Ai-AMU 2000 EN V6
|
| digital_output_count |
4
Datasheet Ai-AMU 2000 EN V6
|
| ethernet_port_count |
4
Datasheet Ai-AMU 2000 EN V6
|
| integrated_data_logger |
Ai-Logger 2000
Datasheet Ai-AMU 2000 EN V6
|
| max_connected_devices |
180
Ai-AMU 2000 - product page
|
| max_connected_inverters |
180
Datasheet Ai-AMU 2000 EN V6
|
| max_devices_per_rs485_port |
30
Datasheet Ai-AMU 2000 EN V6
|
| max_operating_altitude_m |
5000
Datasheet Ai-AMU 2000 EN V6
|
| optical_fiber_sfp_port_count |
2
Datasheet Ai-AMU 2000 EN V6
|
| pid_prevention |
True
Ai-AMU 2000 - product page
|
| pt100_pt1000_input_count |
2
Datasheet Ai-AMU 2000 EN V6
|
| relative_humidity |
0-100%, non-condensing
Datasheet Ai-AMU 2000 EN V6
|
| rs485_port_count |
6
Datasheet Ai-AMU 2000 EN V6
|
| self_consumption_max_w |
380
Datasheet Ai-AMU 2000 EN V6
|
| usb_port_count |
1
Datasheet Ai-AMU 2000 EN V6
|
| wan_port_count |
2
Datasheet Ai-AMU 2000 EN V6
|
Physical / mechanical
| dimensions_mm |
[670, 760, 200]
Datasheet Ai-AMU 2000 EN V6
|
| length_mm |
670
Datasheet Ai-AMU 2000 EN V6
|
| weight_kg |
30.0
Datasheet Ai-AMU 2000 EN V6
|
Installation
| mounting |
Wall mounted, rack mounted, ground mounted
суперечливе
Datasheet Ai-AMU 2000 EN V6
|
Environment
| ip_rating |
IP66
Datasheet Ai-AMU 2000 EN V6
|
| operating_temperature_c |
-30 to 60
Datasheet Ai-AMU 2000 EN V6
|
| operating_temperature_max_c |
60
Datasheet Ai-AMU 2000 EN V6
|
| operating_temperature_min_c |
-30
Datasheet Ai-AMU 2000 EN V6
|
Interfaces & connectors
| documented_ports | [{'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 6, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | RS485 | 6×RS485'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 6, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | Ethernet | 2×WAN, 4×LAN'}, {'port_role': 'TEMPERATURE_SENSOR', 'port_label_from_manual': 'PT100 / PT1000', 'port_type': 'RTD input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 2, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | PT100 / PT1000 | 2'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'ABUS port', 'port_type': 'ABUS', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 2, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | ABUS port | 2'}, {'port_role': 'AC_IN', 'port_label_from_manual': 'AC input', 'port_type': 'L/N(L)+PE', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Electrical | AC input voltage | 100 V ~ 240 V, L / N (L)+PE'}] суперечливе |
Документи
datasheet
Datasheet Ai-AMU 2000 EN V6
product_page
Ai-AMU 2000 - product page
quick_start_guide
QG0086 Ai-AMU 2000 installation guide
Зафіксовані конфлікти
interfaces.documented_ports Review required
[{'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 6, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | RS485 | 6×RS485'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'Ethernet', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 6, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | Ethernet | 2×WAN, 4×LAN'}, {'port_role': 'TEMPERATURE_SENSOR', 'port_label_from_manual': 'PT100 / PT1000', 'port_type': 'RTD input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 2, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | PT100 / PT1000 | 2'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'ABUS port', 'port_type': 'ABUS', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 2, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Basic | ABUS port | 2'}, {'port_role': 'AC_IN', 'port_label_from_manual': 'AC input', 'port_type': 'L/N(L)+PE', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'document': 1, 'page': "column 'Ai-AMU 2000'", 'quote': 'Electrical | AC input voltage | 100 V ~ 240 V, L / N (L)+PE'}] — stored value
[{'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS485 terminal', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Interfaces', 'quote': 'RS485: 6 ports'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'LAN', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Interfaces', 'quote': 'Ethernet: 2xWAN, 4xLAN'}, {'port_role': 'ETHERNET', 'port_label_from_manual': 'WAN', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Interfaces', 'quote': 'Ethernet: 2xWAN, 4xLAN'}, {'port_role': 'USB', 'port_label_from_manual': 'USB', 'port_type': 'USB', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Interfaces', 'quote': 'USB: 1'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DI', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'signal', 'document': 0, 'page': 'Digital I/O', 'quote': 'DI/DO/AI: 4xDI / 4xDO / 4xAI'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'DO', 'port_type': 'digital output', 'direction': 'output', 'electrical_domain': 'signal', 'document': 0, 'page': 'Digital I/O', 'quote': 'DI/DO/AI: 4xDI / 4xDO / 4xAI'}, {'port_role': 'ANALOG_IN', 'port_label_from_manual': 'AI', 'port_type': 'analog input', 'direction': 'input', 'electrical_domain': 'signal', 'document': 0, 'page': 'Digital I/O', 'quote': 'DI/DO/AI: 4xDI / 4xDO / 4xAI'}, {'port_role': 'TEMPERATURE_SENSOR', 'port_label_from_manual': 'PT100/PT1000', 'port_type': 'RTD input', 'direction': 'input', 'electrical_domain': 'signal', 'document': 0, 'page': 'Digital I/O', 'quote': 'PT100/PT1000: 2'}, {'port_role': 'PROPRIETARY_BUS', 'port_label_from_manual': 'ABUS', 'port_type': 'Solplanet ABUS', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Power', 'quote': 'ABUS input: 380V-800V, 3-phase'}, {'port_role': 'AC_IN', 'port_label_from_manual': 'AC input', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'ac', 'document': 0, 'page': 'Power', 'quote': 'AC input: 100V-240V, L/N (L)+PE'}] — incoming package
Detected during import deep-enrich-2026-09-batch19
installation.mounting Review required
Wall mounted, rack mounted, ground mounted — stored value
['wall', 'rack', 'ground'] — Mounting: Wall, rack, or ground mounted
Detected during import deep-enrich-2026-09-batch19
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | One global English datasheet; no regional split documented. |
| withheld:ethernet_port_count | 6 |
| withheld:height_mm | 200 |
| withheld:local_web_ui | true |
| withheld:supported_device_types | ["PV inverters"] |
| withheld:width_mm | 760 |