⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Gateways / Data Loggers

Manufacturer documented GLOBAL

Identity

category gateways
manufacturer TENSE
manufacturer_part_number GSM-MOD
model GSM-MOD
mpn GSM-MOD
product_family GSM Based Modem/Gateway
product_status active
region GLOBAL
series GSM-MOD
variant —

Electrical

antenna 2.2dBi SMA replaceable antenna
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
bandwidth Quand band GSM/GPRS/EDGE [sic - 'Quad band']
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
connection_type GSM
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
iec62056_21 true
GSM-MOD — official product page
impact_resistance 4kV kV
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
indicators Power Led, Relay LED, Signal level LED, Rx and Tx LEDs
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
max_baud_rate Max. 19200bps (For meters IEC62056-21 protocol) bps
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
operating_frequency 50/60Hz. Hz
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
operating_power 1VA(system standby), 10VA(system communicate) VA
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
operating_voltage 85V - 300VAC VAC
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section

Physical / mechanical

enclosure_case_code E1
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
weight <200gr. g
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section

Environment

operating_altitude <2000 meters m
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
operating_temperature -20ºC to 55ºC degC
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section

Interfaces & connectors

device_type GSM/GPRS modem-gateway bridging RS-485 Modbus, RS-232 and optical-probe meter reading to TCP/IP
max_rs485_devices 128 devices
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section - 'RS485 Connection Interface: Max. 128 devices'
modbus_register_map_available False
modbus_register_map_note No register map published for this device.
modbus_rtu true
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section - printed as 'Modbus communucation (For energy analyzers and power factor controllers)' [sic]
modbus_tcp not_stated
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
optical_probe_interface true
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
rs232 true
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section - 'RS232 Connection Interface'
rs485 true
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section

Protection

air_esd_protection 10kV kV
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section
protection_class IP20
Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf) — Monitoring section

Документи

catalog Tense Electronic Technical Catalog (manufacturer document, retrieved from distributor mirror stockled.pt because tense.com.tr robots.txt disallows *.pdf)
product-page GSM-MOD — official product page
user-manual GSM-MOD User Guide (EN)