⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Gateways / Data Loggers

Manufacturer documented GLOBAL

Identity

category gateways
manufacturer UOTEK
manufacturer_part_number UT-6801S
model UT-6801S
mpn UT-6801S
product_family UOTEK serial device servers
product_status active
region GLOBAL
series UT-6801
variant —

Electrical

galvanic_isolation serial port +/-6KV ESD protection, network port 1.5KVAC isolation protection
UT-6801S — official product page — technical parameter table, protection/isolation row
input_voltage DC 12~57.6V
UT-6801S — official product page — technical parameter table, power-input row
power_consumption 12V@50mA
UT-6801S — official product page — technical parameter table, power-consumption row
working_modes VCOM, MCP, TCP Server, TCP Client, UDP Client, Modbus TCP Server, Modbus TCP Client, HTTP Client, MQTT
UT-6801S — official product page — technical parameter table, working-mode row

Physical / mechanical

dimensions 100mm x 80.8mm x 30mm
UT-6801S — official product page — technical parameter table, dimensions row

Environment

ip_rating IP30
UT-6801S — official product page — technical parameter table, protection-rating row
operating_temperature -40~85 degC
UT-6801S — official product page — technical parameter table, operating-temperature row

Interfaces & connectors

device_type 10/100M to 1-port RS-232/485/422 serial device server
home_assistant_modbus_tcp_suitable True
home_assistant_suitability_basis The official product page's working-mode row prints 'Modbus TCP Server' and 'Modbus TCP Client' as named, selectable operating modes distinct from the transparent VCOM/TCP Server/TCP Client modes on the same list. In 'Modbus TCP Server' mode the unit answers a Modbus TCP client on the network side from the Modbus RTU devices on its serial side, which is what Home Assistant's modbus integration (type: tcp) needs. Printed in the technical parameter table of https://www.szutek.com/pro_view-755.html. The per-mode register/slave-mapping detail is in the user manual PDF, which was not read.
modbus_tcp true - 'Modbus TCP Server' and 'Modbus TCP Client' are printed as selectable working modes
UT-6801S — official product page — technical parameter table, working-mode row
network_interface 10/100M with embedded 1.5KV magnetic isolation
UT-6801S — official product page — technical parameter table, network interface row
network_protocols ARP, IP, ICMP, UDP, TCP, HTTP, DHCP, MODBUS
UT-6801S — official product page — technical parameter table, protocol row (printed in Chinese as 'ARP/IP/ICMP/UDP/TCP/HTTP/DHCP/MODBUS...')
rs232 true
UT-6801S — official product page — technical parameter table, serial interface row
rs422 true
UT-6801S — official product page — technical parameter table, serial interface row
rs485 true
UT-6801S — official product page — technical parameter table, serial interface row
serial_baud_rate not stated
UT-6801S — official product page — the baud-rate row is not printed on this product page
serial_ports 1
UT-6801S — official product page — technical parameter table, serial interface row
serial_standard 1 x RS-232/RS-485/RS-422 (7Pin 5.08 pluggable terminal)
UT-6801S — official product page — technical parameter table, serial interface row

Документи

product-brief UT-6801S product brief (szutek.com)
product-page UT-6801S — official product page