База знань › Gateways / Data Loggers
Victron Energy GX Tank 140
Official manufacturer GLOBAL перевірено 23 вересня 2026 р.
Identity
| category | gateways |
| manufacturer | Victron Energy |
| model | GX Tank 140 |
| region | GLOBAL |
| variant | — |
Electrical
| compatible_devices |
Victron GX range of system monitoring products, most commonly the Cerbo GX
GX Tank 140 manual (PDF)
|
| configurable_input_range |
True
GX Tank 140 manual (PDF)
|
| connection_type |
pluggable terminal blocks
GX Tank 140 manual (PDF)
|
| external_sensor_power_input |
Ext. Power connector for channels 1 and 2, with a self-resetting fuse (20mA)
GX Tank 140 manual (PDF)
|
| max_connected_devices |
4
GX Tank 140 manual (PDF)
|
| power_supply |
Self powered from the USB interface; no external power source required
GX Tank 140 manual (PDF)
|
| sensor_excitation_voltage_v |
24
GX Tank 140 manual (PDF)
|
| sensor_supply_current_limit_ma |
20
GX Tank 140 manual (PDF)
|
| supported_device_types |
['4 to 20 mA tank level sender', '0 to 10 V tank level sender']
GX Tank 140 manual (PDF)
|
| supported_sensor_types |
either 4 to 20mA or 0 to 10V tank level sensors
GX Tank 140 manual (PDF)
|
| tank_sensor_input_count |
4
GX Tank 140 manual (PDF)
|
| usb_cable_length_m |
1.5
GX Tank 140 manual (PDF)
|
| warranty_years | 5 |
Interfaces & connectors
| documented_ports | [{'port_role': 'ANALOG_IN', 'port_label_from_manual': 'tank level sensors', 'port_type': 'tank level sender input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 1, 'page': 'GX Tank 140 manual, Introduction', 'quote': 'up to four tank level sensors'}, {'port_role': 'USB', 'port_label_from_manual': 'USB', 'port_type': 'USB', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 1, 'page': 'GX Tank 140 manual, Installation', 'quote': 'Connection to the GX Device via USB interface'}] суперечливе |
| host_interface |
USB (to GX device)
GX Tank 140 manual (PDF)
|
| usb |
True
GX Tank 140 manual (PDF)
|
Certifications
| certifications | CE - EMC Directive 2014/30/EU (EN 61000-6-1:2007, EN 61000-6-3:2007+A1:2011+AC:2012); RoHS 2011/65/EU and 2015/863/EU (EN-IEC 63000:2018); EC REACH Regulation (EC 1907/2006) |
Документи
certificate
Declaration of Conformity - GX Tank 140
product_page
GX Tank 140
user_manual
GX Tank 140 manual (HTML5)
user_manual
GX Tank 140 manual (PDF)
Зафіксовані конфлікти
interfaces.documented_ports Review required
[{'port_role': 'ANALOG_IN', 'port_label_from_manual': 'tank level sensors', 'port_type': 'tank level sender input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 4, 'document': 1, 'page': 'GX Tank 140 manual, Introduction', 'quote': 'up to four tank level sensors'}, {'port_role': 'USB', 'port_label_from_manual': 'USB', 'port_type': 'USB', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 1, 'page': 'GX Tank 140 manual, Installation', 'quote': 'Connection to the GX Device via USB interface'}] — stored value
[{'port_role': 'USB', 'port_label_from_manual': 'USB cable', 'port_type': 'USB', 'direction': 'output', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'manual, installation', 'quote': 'non-detachable 1.5m long USB cable'}, {'port_role': 'ANALOG_IN', 'port_label_from_manual': 'Tank level sensor inputs (4 channels)', 'port_type': 'pluggable terminal block', 'direction': 'input', 'electrical_domain': 'SIGNAL', 'document': 0, 'page': 'manual, introduction', 'quote': 'either 4 to 20mA or 0 to 10V tank level sensors'}, {'port_role': 'DC_OUT', 'port_label_from_manual': 'Ext. Power', 'port_type': 'pluggable terminal block', 'direction': 'output', 'electrical_domain': 'DC', 'document': 0, 'page': 'manual, installation, channels 1 and 2', 'quote': "External power via labelled 'Ext. Power' connector with self-resetting fuse (20mA)"}] — incoming package
Detected during import deep-enrich-2026-09-batch19
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | One worldwide Victron product page; part number BPP920140100. |
| withheld:bluetooth | false |
| withheld:can | false |
| withheld:cellular_4g | false |
| withheld:cloud_required | false |
| withheld:ethernet | false |
| withheld:external_interface | "Tank level sender inputs" |
| withheld:local_access | true |
| withheld:rs232 | false |
| withheld:rs485 | false |
| withheld:wifi | false |