CHINT CPS ECH12K/US
Official manufacturer US перевірено 23 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | CHINT |
| model | CPS ECH12K/US |
| region | US |
Electrical
| backup_max_apparent_power_va |
12000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| backup_output |
True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| backup_switchover_time_ms |
20
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| battery_supported |
True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| battery_voltage_class |
LV
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| battery_voltage_max_v |
60
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| battery_voltage_min_v |
40
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| cec_efficiency_percent |
96.5
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| generator_input |
True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| generator_max_input_current_a |
100
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| generator_max_input_power_w |
24000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| grid_frequency_hz |
60
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| grid_frequency_range_hz |
[57, 63]
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| grid_standards |
['IEEE 1547-2018', 'HECO', 'CA Rule 21']
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| has_internal_pv_input |
True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_ac_output_current_a |
50.0
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_ac_power_w |
12000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_charge_current_a |
200
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_charge_power_w |
10000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_discharge_current_a |
200
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_discharge_power_w |
10000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_efficiency_percent |
97.5
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_grid_input_current_a |
200
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_input_current_per_mppt_a |
30
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_pv_power_w |
18000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_pv_voltage_v |
600
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| max_short_circuit_current_per_mppt_a |
40
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| mppt_voltage_max_v |
550
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| mppt_voltage_min_v |
120
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| nominal_grid_voltage_v |
240
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| number_of_mppt |
3
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
|
| number_of_pv_inputs |
6
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| parallel_supported |
True
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
|
| phase_count |
1
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| startup_voltage_v |
150
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| strings_per_mppt_distribution |
[2, 2, 2]
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| warranty_years |
10
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
Physical / mechanical
| dimensions_mm |
[912, 518, 234]
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| weight_kg |
46.2
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
Environment
| operating_temperature_max_c |
60
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
| operating_temperature_min_c |
-25
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
Interfaces & connectors
| communications |
['Wi-Fi', 'CAN', 'RS485']
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
|
| documented_ports | [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV terminal', 'port_type': 'screw terminal / PV terminal block', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 6, 'limits': {'max_pv_voltage_v': 600, 'max_input_current_per_mppt_a': 30}, 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'PV terminal (connects to PV panels)'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery terminal', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'Battery terminal (connects to battery)'}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid terminal', 'port_type': 'AC terminal', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'Grid terminal (connects to grid cables)'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Load terminal', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'Load terminal (connects to backup load cables)'}, {'port_role': 'METER', 'port_label_from_manual': 'CPS Meter Kit port', 'port_type': 'communication connector', 'direction': 'input', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'CAN', 'port_label_from_manual': 'BMS (CAN)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'RS485', 'port_label_from_manual': 'EMS/BMS (RS485)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'PARALLEL_OUT', 'port_label_from_manual': 'parallel communication connection', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'WIFI', 'port_label_from_manual': 'Wi-Fi', 'port_type': 'integrated wireless', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Technical data, General Data: Inverter monitoring', 'quote': 'Inverter monitoring: Wi-Fi'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'Generator Input', 'port_type': 'AC terminal', 'direction': 'input', 'electrical_domain': 'AC', 'limits': {'max_input_current_a': 100, 'max_input_power_w': 24000}, 'document': 0, 'page': 'Technical data, Generator Input', 'quote': 'Generator Input - Max. input current: 100 A'}] |
| meter_interface |
True
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
|
Protection
| ingress_protection |
NEMA 4X
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
Certifications
| certifications |
['CSA 107.1-16', 'UL 1741/SA', 'UL 1741 SB', 'UL 1998', 'UL 1699B', 'FCC Part 15']
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
|
Документи
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | North-American product: split-phase 120/240 V (208 V selectable), 60 Hz, certified to UL 1741 SA/SB and IEEE 1547-2018. Sold by Chint Power Systems America under the CPS brand. ANMA already spells this manufacturer CHINT (manufacturer_key 'chint'), so that spelling is used; 'CPS' is carried in the printed model designation and in series. |