⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

CHINT CPS ECH9.6K/US

Побудувати систему з цим продуктом

Official manufacturer US перевірено 23 вересня 2026 р.

Identity

category inverters
manufacturer CHINT
model CPS ECH9.6K/US
region US

Electrical

backup_max_apparent_power_va 9600
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
backup_output True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
backup_switchover_time_ms 20
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
battery_supported True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
battery_voltage_class LV
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
battery_voltage_max_v 60
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
battery_voltage_min_v 40
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
cec_efficiency_percent 96.5
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
generator_input True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
generator_max_input_current_a 100
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
generator_max_input_power_w 24000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
grid_frequency_hz 60
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
grid_frequency_range_hz [57, 63]
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
grid_standards ['IEEE 1547-2018', 'HECO', 'CA Rule 21']
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
has_internal_pv_input True
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_ac_output_current_a 40.0
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_ac_power_w 9600
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_charge_current_a 200
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_charge_power_w 10000
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_discharge_current_a 192
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_discharge_power_w 9600
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_efficiency_percent 97.5
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_grid_input_current_a 200
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_input_current_per_mppt_a 30
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_pv_power_w 14400
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_pv_voltage_v 600
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
max_short_circuit_current_per_mppt_a 40
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
mppt_voltage_max_v 550
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
mppt_voltage_min_v 120
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
nominal_grid_voltage_v 240
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
number_of_mppt 3
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
number_of_pv_inputs 6
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
parallel_supported True
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
phase_count 1
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
startup_voltage_v 150
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
strings_per_mppt_distribution [2, 2, 2]
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
warranty_years 10
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)

Physical / mechanical

dimensions_mm [912, 518, 234]
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
weight_kg 46.2
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)

Environment

operating_temperature_max_c 60
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
operating_temperature_min_c -25
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)

Interfaces & connectors

communications ['Wi-Fi', 'CAN', 'RS485']
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
documented_ports [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV terminal', 'port_type': 'screw terminal / PV terminal block', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 6, 'limits': {'max_pv_voltage_v': 600, 'max_input_current_per_mppt_a': 30}, 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'PV terminal (connects to PV panels)'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery terminal', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'Battery terminal (connects to battery)'}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid terminal', 'port_type': 'AC terminal', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'Grid terminal (connects to grid cables)'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Load terminal', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 1, 'page': 'Page 14, Table 2-2 Wire Box Components', 'quote': 'Load terminal (connects to backup load cables)'}, {'port_role': 'METER', 'port_label_from_manual': 'CPS Meter Kit port', 'port_type': 'communication connector', 'direction': 'input', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'CAN', 'port_label_from_manual': 'BMS (CAN)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'RS485', 'port_label_from_manual': 'EMS/BMS (RS485)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'PARALLEL_OUT', 'port_label_from_manual': 'parallel communication connection', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 1, 'page': 'Page 47, Table 4-3 Communication Cable Ports', 'quote': '14-pin terminal, CPS Meter Kit port, BMS (CAN), EMS/BMS (RS485), and parallel communication connection'}, {'port_role': 'WIFI', 'port_label_from_manual': 'Wi-Fi', 'port_type': 'integrated wireless', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Technical data, General Data: Inverter monitoring', 'quote': 'Inverter monitoring: Wi-Fi'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'Generator Input', 'port_type': 'AC terminal', 'direction': 'input', 'electrical_domain': 'AC', 'limits': {'max_input_current_a': 100, 'max_input_power_w': 24000}, 'document': 0, 'page': 'Technical data, Generator Input', 'quote': 'Generator Input - Max. input current: 100 A'}]
meter_interface True
CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)

Protection

ingress_protection NEMA 4X
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)

Certifications

certifications ['CSA 107.1-16', 'UL 1741/SA', 'UL 1741 SB', 'UL 1998', 'UL 1699B', 'FCC Part 15']
Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)

Документи

datasheet Technical Data — CPS ECH7.6-12K Single-Phase Hybrid Inverter (dated 4-20-2026)
manual CPS Single-Phase Hybrid Inverter User Manual (4-20-2026)
product_page Chint Power Systems — Downloads (product and document index)

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesNorth-American product: split-phase 120/240 V (208 V selectable), 60 Hz, certified to UL 1741 SA/SB and IEEE 1547-2018. Sold by Chint Power Systems America under the CPS brand. ANMA already spells this manufacturer CHINT (manufacturer_key 'chint'), so that spelling is used; 'CPS' is carried in the printed model designation and in series.