Identity

category inverters
manufacturer CHINT
model CPS SCA60KTL-DO/US-480
region US
variant 3-phase

Electrical

ac_voltage_range_v [422, 528]
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
backup_output False
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
battery_supported False
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
cec_efficiency_percent 98.5
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
generator_input False
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
grid_frequency_hz 60
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
has_internal_pv_input True
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_ac_output_current_a 72.2-79.4 A
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_ac_power_w 66000
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_efficiency_percent 98.8
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_input_current_per_mppt_a 38
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_pv_power_w 90000
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_pv_voltage_v 1000
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
max_short_circuit_current_per_mppt_a 54.4
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
mppt_voltage_max_v 850
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
mppt_voltage_min_v 540
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
night_consumption_w 1
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
nominal_grid_voltage_v 480
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
number_of_mppt 3
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
operating_dc_voltage_max_v 950
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
operating_dc_voltage_min_v 200
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
phase_count 3
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
power_factor >0.99 (±0.8 adjustable)
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
rated_ac_power_w 60000
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
smart_load False
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
startup_voltage_v 330
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
strings_per_mppt_distribution [5, 5, 5]
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
topology Transformerless
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
warranty_years 10
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)

Physical / mechanical

weight_kg 56.0
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)

Environment

operating_temperature_max_c 60
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
operating_temperature_min_c -30
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)

Interfaces & connectors

communications ['RS485']
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
documented_ports [{'port_role': 'PV_IN', 'port_label_from_manual': 'DC inputs per MPPT', 'port_type': 'DC input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 5, 'limits': {'max_pv_voltage_v': 1000, 'max_short_circuit_current_per_mppt_a': 54.4}, 'document': 0, 'page': 'Technical data, DC Input', 'quote': 'DC inputs per MPPT: 5'}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid connection type 3Φ / PE / N (neutral optional)', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Technical data, AC Output', 'quote': 'Grid connection type | 3Φ / PE / N (neutral optional)'}, {'port_role': 'RS485', 'port_label_from_manual': 'Inverter communication Modbus RS485', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Technical data, General', 'quote': 'Inverter communication | Modbus RS485'}]
protocols ['Modbus']
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)

Protection

ingress_protection NEMA 4X
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)

Certifications

certifications ['UL 1741-SA/SB', 'UL 1699B', 'IEEE 1547-2018']
Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)

Документи

datasheet Technical Data 50/60 kW, 1000 Vdc String Inverters for North America (dated 8-17-2026)
manual CPS SCA36/50/60KTL-DO/US-480 User Manual Rev 4.0
product_page Chint Power Systems — Downloads (product and document index)

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesNorth-American commercial string inverter: 480 Vac three-phase, 60 Hz, UL 1741-SA/SB and IEEE 1547-2018. ANMA already spells this manufacturer CHINT (manufacturer_key 'chint'); 'CPS' is part of the printed designation and the series name.
withheld:number_of_pv_inputs15