Deye SUN-10K-SG01HP3-EU-DM2
Official manufacturer EU перевірено 25 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | Deye |
| model | SUN-10K-SG01HP3-EU-DM2 |
| region | EU |
Electrical
| backup_output |
True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
|
| battery_chemistry_supported |
['Lithium-ion']
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| battery_supported |
True
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| battery_voltage_class |
HV
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| battery_voltage_max_v |
700
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| battery_voltage_min_v |
160
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| euro_efficiency_pct |
97.0
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| generator_input |
True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
|
| grid_frequency_hz |
[50, 60]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| has_internal_pv_input |
True
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_ac_apparent_power_va |
11000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_ac_input_current_a |
16.7
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_ac_output_current_a |
16.0
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_charge_current_a |
37
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| max_continuous_ac_passthrough_a |
35
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_discharge_current_a |
37
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| max_efficiency_pct |
97.6
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_input_current_per_mppt_a |
[18, 18]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_parallel_units |
10
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_pv_input_power_w |
20000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_pv_voltage_v |
1000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| max_short_circuit_current_per_mppt_a |
[27, 27]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| mppt_voltage_max_v |
850
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| mppt_voltage_min_v |
150
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| nominal_grid_voltage_v |
400
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| number_of_battery_inputs |
1
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
|
| number_of_mppt |
2
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| number_of_pv_inputs |
2
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| parallel_supported |
True
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| peak_power_off_grid |
1.5x rated, 10s
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| phase_count |
3
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| rated_ac_power_w |
10000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| rated_pv_input_voltage_v |
600
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| smart_load |
True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
|
| startup_voltage_v |
180
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| strings_per_mppt_distribution |
[1, 1]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
Environment
| ip_rating |
IP65
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
Interfaces & connectors
| communications |
['WiFi', 'RS485', 'CAN']
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
|
| ct_interface |
True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
|
| documented_ports | [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV1 & PV2', 'port_type': 'MC4-compatible DC connector', 'direction': 'input', 'electrical_domain': 'DC', 'document': 2, 'page': '§2.1 / §3.6 p. 15-18', 'quote': '"PV input with two MPPT" (Section 2.1); Two separate MPPT tracker inputs for photovoltaic arrays', 'quantity': 2}, {'port_role': 'BATTERY', 'port_label_from_manual': 'BAT (Battery Input)', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 2, 'page': '§2.1 / §3.4 p. 13-14', 'quote': '"Battery input" (Section 2.1); Connection point for battery system with DC+/DC- connectors', 'quantity': 1}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid', 'port_type': 'AC terminal block', 'direction': 'input', 'electrical_domain': 'AC', 'document': 2, 'page': '§2.1 / §3.5 p. 19-21', 'quote': '"Grid" (Section 2.1); Three-phase grid connection (L1, L2, L3, N, PE)', 'quantity': 1}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Load', 'port_type': 'AC terminal block', 'direction': 'output', 'electrical_domain': 'AC', 'document': 2, 'page': '§2.1 / §3.5 p. 19-21', 'quote': '"Load" (Section 2.1); "Backup Load" connection for critical circuits', 'quantity': 1}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC terminal block', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 2, 'page': '§2.1 / §3.5 p. 21 / §5.9', 'quote': '"Generator input" (Section 2.1); "Smart Load Output: Use the GEN port as an AC output port, and the load connected to this port can be controlled on/off by the hybrid inverter" (Section 5.9)', 'quantity': 1}, {'port_role': 'CAN', 'port_label_from_manual': 'BMS', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11 / §3.4 p. 24', 'quote': '"BMS port for battery communication port"'}, {'port_role': 'METER', 'port_label_from_manual': 'Meter', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11 / §3.7 p. 25-27', 'quote': '"Meter: for energy meter communication"'}, {'port_role': 'CT', 'port_label_from_manual': 'CT1 / CT2 / CT3', 'port_type': 'CT input', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11 / §3.7 p. 25-27', 'quote': 'Three current transformers (CT1, CT2, CT3) for "zero export to CT" mode', 'quantity': 3}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485 port', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"RS485 port"; Modbus communication interface for monitoring'}, {'port_role': 'PARALLEL_IN', 'port_label_from_manual': 'Parallel port', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"Parallel communication port 1" and "Parallel communication port 2"', 'quantity': 2}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DRM port', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"Logic interface for AS/NZS 4777.2:2020"'}, {'port_role': 'DRY_CONTACT', 'port_label_from_manual': 'Gen Start', 'port_type': 'dry contact', 'direction': 'output', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"Dry contact signal for startup the diesel generator"'}, {'port_role': 'RELAY', 'port_label_from_manual': 'Dry 1 / Dry 2', 'port_type': 'relay output', 'direction': 'output', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': 'Relay outputs; Dry-2 is "reserved"', 'quantity': 2}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Rsd+/Rsd-', 'port_type': 'terminal', 'direction': 'output', 'electrical_domain': 'DC', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"12Vdc" output when battery connected and inverter is ON'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Shut Down B-B', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': 'Shutdown trigger; "12Vdc of RSD+ & RSD- will disappear immediately"'}] |
| meter_interface |
True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
|
Документи
product_page
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | Published only in an EU edition (220/380 V, 230/400 V, 3L+N+PE, EU grid codes); the -EU token is part of the model designation. |