⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

Deye SUN-10K-SG01HP3-EU-DM2

Побудувати систему з цим продуктом

Official manufacturer EU перевірено 25 вересня 2026 р.

Identity

category inverters
manufacturer Deye
model SUN-10K-SG01HP3-EU-DM2
region EU

Electrical

backup_output True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
battery_chemistry_supported ['Lithium-ion']
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
battery_supported True
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
battery_voltage_class HV
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
battery_voltage_max_v 700
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
battery_voltage_min_v 160
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
euro_efficiency_pct 97.0
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
generator_input True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
grid_frequency_hz [50, 60]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
has_internal_pv_input True
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_ac_apparent_power_va 11000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_ac_input_current_a 16.7
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_ac_output_current_a 16.0
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_charge_current_a 37
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
max_continuous_ac_passthrough_a 35
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_discharge_current_a 37
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
max_efficiency_pct 97.6
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_input_current_per_mppt_a [18, 18]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_parallel_units 10
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_pv_input_power_w 20000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_pv_voltage_v 1000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
max_short_circuit_current_per_mppt_a [27, 27]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
mppt_voltage_max_v 850
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
mppt_voltage_min_v 150
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
nominal_grid_voltage_v 400
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
number_of_battery_inputs 1
【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
number_of_mppt 2
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
number_of_pv_inputs 2
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
parallel_supported True
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
peak_power_off_grid 1.5x rated, 10s
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
phase_count 3
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
rated_ac_power_w 10000
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
rated_pv_input_voltage_v 600
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
smart_load True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
startup_voltage_v 180
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
strings_per_mppt_distribution [1, 1]
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page

Environment

ip_rating IP65
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page

Interfaces & connectors

communications ['WiFi', 'RS485', 'CAN']
SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page
ct_interface True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
documented_ports [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV1 & PV2', 'port_type': 'MC4-compatible DC connector', 'direction': 'input', 'electrical_domain': 'DC', 'document': 2, 'page': '§2.1 / §3.6 p. 15-18', 'quote': '"PV input with two MPPT" (Section 2.1); Two separate MPPT tracker inputs for photovoltaic arrays', 'quantity': 2}, {'port_role': 'BATTERY', 'port_label_from_manual': 'BAT (Battery Input)', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 2, 'page': '§2.1 / §3.4 p. 13-14', 'quote': '"Battery input" (Section 2.1); Connection point for battery system with DC+/DC- connectors', 'quantity': 1}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid', 'port_type': 'AC terminal block', 'direction': 'input', 'electrical_domain': 'AC', 'document': 2, 'page': '§2.1 / §3.5 p. 19-21', 'quote': '"Grid" (Section 2.1); Three-phase grid connection (L1, L2, L3, N, PE)', 'quantity': 1}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Load', 'port_type': 'AC terminal block', 'direction': 'output', 'electrical_domain': 'AC', 'document': 2, 'page': '§2.1 / §3.5 p. 19-21', 'quote': '"Load" (Section 2.1); "Backup Load" connection for critical circuits', 'quantity': 1}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC terminal block', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 2, 'page': '§2.1 / §3.5 p. 21 / §5.9', 'quote': '"Generator input" (Section 2.1); "Smart Load Output: Use the GEN port as an AC output port, and the load connected to this port can be controlled on/off by the hybrid inverter" (Section 5.9)', 'quantity': 1}, {'port_role': 'CAN', 'port_label_from_manual': 'BMS', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11 / §3.4 p. 24', 'quote': '"BMS port for battery communication port"'}, {'port_role': 'METER', 'port_label_from_manual': 'Meter', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11 / §3.7 p. 25-27', 'quote': '"Meter: for energy meter communication"'}, {'port_role': 'CT', 'port_label_from_manual': 'CT1 / CT2 / CT3', 'port_type': 'CT input', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11 / §3.7 p. 25-27', 'quote': 'Three current transformers (CT1, CT2, CT3) for "zero export to CT" mode', 'quantity': 3}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485 port', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"RS485 port"; Modbus communication interface for monitoring'}, {'port_role': 'PARALLEL_IN', 'port_label_from_manual': 'Parallel port', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"Parallel communication port 1" and "Parallel communication port 2"', 'quantity': 2}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DRM port', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"Logic interface for AS/NZS 4777.2:2020"'}, {'port_role': 'DRY_CONTACT', 'port_label_from_manual': 'Gen Start', 'port_type': 'dry contact', 'direction': 'output', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"Dry contact signal for startup the diesel generator"'}, {'port_role': 'RELAY', 'port_label_from_manual': 'Dry 1 / Dry 2', 'port_type': 'relay output', 'direction': 'output', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': 'Relay outputs; Dry-2 is "reserved"', 'quantity': 2}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Rsd+/Rsd-', 'port_type': 'terminal', 'direction': 'output', 'electrical_domain': 'DC', 'document': 2, 'page': '§3.3 p. 11', 'quote': '"12Vdc" output when battery connected and inverter is ON'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Shut Down B-B', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 11', 'quote': 'Shutdown trigger; "12Vdc of RSD+ & RSD- will disappear immediately"'}]
meter_interface True
【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en

Документи

datasheet 【B】Datasheet_SUN-5/6/8/10/12K-SG01HP3-EU-DM2_20260911_en
manual 【B】Manual_SUN-5-12K-SG01HP3-EU-DM2_20260224_en
product_page SUN-5/6/8/10/12K-SG01HP3-EU-DM2 product page

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesPublished only in an EU edition (220/380 V, 230/400 V, 3L+N+PE, EU grid codes); the -EU token is part of the model designation.