Deye SUN-12K-SG01HP3-EU-AM2
Official manufacturer EU перевірено 25 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | Deye |
| model | SUN-12K-SG01HP3-EU-AM2 |
| region | EU |
Electrical
| backup_output |
True
【B】Manual_SUN-5-25K-SG01HP3-EU-AM2_20260224_en
|
| battery_chemistry_supported |
['Lithium-ion']
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| battery_supported |
True
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| battery_voltage_class |
HV
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| battery_voltage_max_v |
700
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| battery_voltage_min_v |
160
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| euro_efficiency_pct |
97.0
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| generator_input |
True
【B】Manual_SUN-5-25K-SG01HP3-EU-AM2_20260224_en
|
| grid_frequency_hz |
[50, 60]
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| grid_standards |
['IEC 61727', 'IEC 62116', 'CEI 0-21', 'EN 50549', 'NRS 097', 'RD 140', 'UNE 217002', 'OVE-Richtlinie R25', 'G98', 'G99', 'VDE-AR-N 4105']
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| has_internal_pv_input |
True
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_ac_apparent_power_va |
13200
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_ac_input_current_a |
20.0
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_ac_output_current_a |
19.2
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_charge_current_a |
50
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| max_continuous_ac_passthrough_a |
40
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_discharge_current_a |
50
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| max_efficiency_pct |
97.6
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_parallel_units |
10
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_pv_input_power_w |
24000
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| max_pv_voltage_v |
1000
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| mppt_voltage_max_v |
850
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| mppt_voltage_min_v |
150
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| nominal_grid_voltage_v |
400
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| number_of_battery_inputs |
1
【B】Datasheet_SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2_20260911_en
|
| number_of_mppt |
2
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| parallel_supported |
True
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| peak_power_off_grid |
1.5x rated, 10s
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| phase_count |
3
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| rated_ac_power_w |
12000
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| smart_load |
True
【B】Manual_SUN-5-25K-SG01HP3-EU-AM2_20260224_en
|
| startup_voltage_v |
180
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
Environment
| ip_rating |
IP65
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
Interfaces & connectors
| communications |
['RS485', 'RS232', 'CAN', 'GPRS/WiFi/Bluetooth/4G/LAN (optional monitoring dongle)']
SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 product page
|
| ct_interface |
True
【B】Manual_SUN-5-25K-SG01HP3-EU-AM2_20260224_en
|
| documented_ports | [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV1, PV2', 'port_type': 'MC4-compatible DC connector', 'direction': 'input', 'electrical_domain': 'DC', 'document': 2, 'page': '§3.6 p. 20-23', 'quote': '"Before connecting to PV modules, please install a separately DC circuit breaker between inverter and PV modules."', 'quantity': 2}, {'port_role': 'BATTERY', 'port_label_from_manual': 'BAT (Battery Input)', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 2, 'page': '§3.4 p. 18-19', 'quote': '"For safe operation and compliance, a separate DC over-current protector or disconnect device is required between the battery and the inverter."', 'quantity': 1}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid', 'port_type': 'AC terminal block', 'direction': 'input', 'electrical_domain': 'AC', 'document': 2, 'page': '§3.5 p. 19-20', 'quote': '"There are three terminal blocks with \'Grid\' \'Load\' and \'GEN\' markings. Please do not misconnect input and output connectors."', 'quantity': 1}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Load', 'port_type': 'AC terminal block', 'direction': 'output', 'electrical_domain': 'AC', 'document': 2, 'page': '§3.5 p. 19-20', 'quote': '"There are three terminal blocks with \'Grid\' \'Load\' and \'GEN\' markings." "Backup Load" is the dedicated output port for essential loads during grid outages', 'quantity': 1}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC terminal block', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 2, 'page': '§3.5 p. 19-20 / §3.13 p. 27 / §5.9', 'quote': '"Connect the diesel generator to the grid input port" or use as output for smart load control; "Smart Load Output: Use the GEN port as an AC output port, and the load connected to this port can be controlled on/off by the hybrid inverter" (Section 5.9)', 'quantity': 1}, {'port_role': 'CAN', 'port_label_from_manual': 'BMS1 / BMS2', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15', 'quote': '"BMS1: BMS port for battery communication port. BMS2: reserved."', 'quantity': 2}, {'port_role': 'METER', 'port_label_from_manual': 'Meter', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15 / §3.7 p. 21-24', 'quote': '"Meter: for energy meter communication."'}, {'port_role': 'CT', 'port_label_from_manual': 'CT-R / CT-S / CT-T', 'port_type': 'CT input', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15 / §3.7.1 p. 22', 'quote': 'Three current transformer connections for grid power measurement in zero-export modes', 'quantity': 3}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15', 'quote': '"RS485: RS485 port"'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15', 'quote': '"CAN: reserved."'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DRM', 'port_type': 'terminal', 'direction': 'input', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15', 'quote': '"DRM: Logic interface for AS/NZS 4777.2:2020."'}, {'port_role': 'PARALLEL_IN', 'port_label_from_manual': 'Parallel_1 / Parallel_2', 'port_type': 'RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 15', 'quote': '"Parallel communication port" for connecting multiple inverters in parallel arrays', 'quantity': 2}, {'port_role': 'DRY_CONTACT', 'port_label_from_manual': 'G-start (1,2)', 'port_type': 'dry contact', 'direction': 'output', 'electrical_domain': 'communication', 'document': 2, 'page': '§3.3 p. 16', 'quote': '"G-start (1,2): dry contact signal for startup the diesel generator."', 'quantity': 1}] |
| meter_interface |
True
【B】Manual_SUN-5-25K-SG01HP3-EU-AM2_20260224_en
|
Документи
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | Published only in an EU edition (220/380 V, 230/400 V, 3L+N+PE, EU grid codes); the -EU token is part of the model designation. |