⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

Enphase IQ8M

Побудувати систему з цим продуктом

Official manufacturer NA перевірено 19 вересня 2026 р.

Identity

brand Enphase
category inverters
generation IQ8
manufacturer Enphase Energy суперечливе
market_version US/Canada, 240 V split-phase
model IQ8M
product_family IQ8 Series Microinverters
product_status active
region —
sku IQ8M-72-2-US (IQ Connector) / IQ8M-72-M-US (MC4)

Electrical

ac_coupling_support True
backup_eps_output_support True
battery_support False
battery_type —
battery_voltage_class —
battery_voltage_max_v —
battery_voltage_min_v —
communication_can False
communication_ethernet —
communication_rs485 False
communication_wifi —
ct_support —
generator_input_support —
grid_certifications ['CA Rule 21 (UL 1741-SA)', 'IEEE 1547:2018 (UL 1741-SB 3rd Ed.)', 'UL 62109-1', 'FCC Part 15 Class B']
grid_export_control —
home_assistant_integration —
max_ac_power_kw 0.33
max_battery_charge_current_a —
max_battery_charge_power_kw —
max_battery_discharge_current_a —
max_dc_voltage_v 60
max_input_current_per_mppt_a 12
max_pv_input_power_w —
max_short_circuit_current_per_mppt_a 20
modbus_rtu —
modbus_tcp —
mppt_max_voltage_v 45
mppt_min_voltage_v 30
num_mppt 1
officially_supported_battery_brands ['Enphase IQ Battery (proprietary ecosystem only)']
phase_type single-phase
pv_inputs_per_mppt 1
rated_ac_power_kw 0.325
smart_meter_support —
startup_voltage_v 22 (min start voltage; max start voltage 58)
DATA SHEET - IQ8M and IQ8A Microinverters (IQ8M-72-2-US) — INPUT DATA (DC), 'Min. / Max. start voltage 22 / 58 V'
sunspec_support —
topology grid-tie microinverter (grid-forming with IQ Battery + IQ System Controller 2)

Physical / mechanical

depth_mm 30.2
enclosure_material Class II double-insulated, corrosion-resistant polymeric enclosure
height_mm 212
mounting_type ['rooftop']
torque_specs 6 mm (1/4 in) mounting hardware 5 N.m (45-50 in-lb); 8 mm (5/16 in) mounting hardware 9 N.m (80-85 in-lb)
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A, IQ8H — installation manual p.17
weight_kg 1.08
width_mm 175

Installation

clearance_bottom_mm 19
Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A, IQ8H — installation manual p.17
clearance_top_mm 13
direct_sunlight_restriction must be mounted under the PV module, protected from direct rain and sun
indoor_outdoor outdoor, wet-location approved (NEMA 250 type 6)
mounting_orientation horizontal (bracket side up) or vertical, always under the PV module
orientation_forbidden ['upside down']

Environment

cooling_method natural convection - no fans
nema_rating NEMA 250, type 6
operating_temperature_c -40 to +60

Interfaces & connectors

ac_terminal_type Enphase IQ Connector on IQ Cable (12 AWG)
powerline_communication proprietary PLC to IQ Gateway
protocol_notes Monitoring, grid profile and firmware are handled by the IQ Gateway; no port on the microinverter.
pv_connector_type Enphase DC connector + Q-DCC-2 MC4 adapter (IQ8M-72-2-US) or integrated Staubli MC4 (IQ8M-72-M-US)

Controls & display

display_type —
leds flashing green = normal + gateway comms; flashing orange = grid OK, no gateway comms; flashing red = grid absent/out of spec; solid red = DC Resistance Low, Power Off

Protection

anti_islanding yes (IEEE 1547:2018 / UL 1741-SB)
overvoltage_category DC port: overvoltage class II
protection_class Class II double-insulated

Certifications

emc ['FCC Part 15 Class B', 'ICES-0003 Class B']
grid_codes ['CA Rule 21 (UL 1741-SA)', 'IEEE 1547:2018 (UL 1741-SB 3rd Ed.)']
safety ['UL 62109-1', 'CAN/CSA-C22.2 NO. 107.1-01']

Warranty & service

standard_years up to 25 (limited warranty per datasheet wording)

Документи

datasheet DATA SHEET - IQ8M and IQ8A Microinverters (IQ8M-72-2-US) rev IQ8MA-12A-DS-0069-03-EN-US-2022-12-27
datasheet DATA SHEET - IQ8M/IQ8A with integrated MC4 connectors (IQ8M-72-M-US) rev DSH-00205-5.0-EN-2025-08-22
installation-manual Installation and Operation Manual - Enphase IQ8, IQ8+, IQ8M, IQ8A, IQ8H

Зафіксовані конфлікти

identity.manufacturer Review required
Enphase Energy — stored value
Enphase — incoming package
Detected during import inverter-mppt-topology-2026-09-batch06

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Commonly used module pairingsW 260 - 460
Max. module IscA 20
Min./Max. start voltageV 22 / 58
Operating rangeV 16 - 58
Overvoltage class DC portII
withheld:pv.mppt_topology_notation"PV array configuration: 1 x 1 Ungrounded array"