FIMER REACT2-UNO-5.0-TL
Official manufacturer EU перевірено 25 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | FIMER |
| model | REACT2-UNO-5.0-TL |
| region | EU |
| variant | — |
Electrical
| ac_frequency_hz | 50/60 |
| ac_voltage_range_v | 180...264 |
| altitude_max_m | 2000 |
| battery_charge_power_kw |
1.6 kW, 3.2 kW, 4.8 kW
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| battery_modules_supported |
1, 2, 3
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| communication_interfaces | Wi-Fi, 2 x Ethernet, RS485; Modbus TCP (SunSpec), Modbus RTU (SunSpec), ABB-free@home® |
| cooling_method | Natural |
| dc_input_voltage_range_v | 0.7 x Vstart...575 (min 90) |
| dc_switch_rating | 25 A / 575 V per MPPT |
| euro_efficiency_pct | 96.6 |
| grid_standards | CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 413, AS/NZS 4777.2, C10/11, IEC 61727, IEC 62116 |
| isolation | Transformerless (no galvanic isolation) |
| max_ac_current_a | 22 |
| max_ac_output_current_a |
22
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| max_ac_power_w | 5000 |
| max_apparent_power_va | 5000 |
| max_dc_power_per_mppt_w |
3000
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| max_efficiency_pct | 97.1 |
| max_input_current_per_mppt_a | 13.5 |
| max_pv_current_a |
27 A / 13,5 A
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| max_pv_input_power_w | 8000 |
| max_pv_voltage_v | 575 |
| max_short_circuit_current_a | 15.0 |
| mppt_voltage_range_v | 195...480 |
| noise_level_db | < 50 dB(A) @ 1 m |
| nominal_ac_voltage_v | 230 |
| number_of_mppt |
2
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| number_of_pv_inputs |
2
суперечливе
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| power_factor_range | > 0.995, adj. ± 0.1 - 1 |
| rated_ac_power_w |
5000
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| rated_dc_input_power_w |
6000
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| rated_dc_power_w | 6000 |
| relative_humidity_pct | 4...100 condensing |
| startup_voltage_v | 200 (adj. 120...350) |
| suggested_max_dc_input_power_w |
8000
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| thd_pct | < 3 |
| topology | Transformerless |
Physical / mechanical
| depth_mm |
229
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| dimensions_mm | 740 x 490 x 229 |
| height_mm |
740
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| weight_kg |
22
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| width_mm |
490
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
Environment
| operating_temperature_max_c |
55
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| operating_temperature_min_c |
-20
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| operating_temperature_range_c | -20...+55 (derating above 45) |
Interfaces & connectors
| protocols |
['Modbus TCP (SunSpec)', 'Modbus RTU (SunSpec)', 'ABB-free@home']
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
Protection
| max_external_ac_overcurrent_protection |
25 A
REACT 2 Data sheet Rev E (FIMER_REACT2-PV-STORAGE-3.6-5-TL-EN-REV_E)
|
| max_external_ac_overcurrent_protection_a | 25 |
| protection_degree_ip | IP65 |
| protections | DC reverse polarity protection (from limited current source); input overvoltage protection for each MPPT - varistor; output overvoltage protection - 2 varistors (L-N / L-PE); DC switch 25 A / 575 V per MPPT; anti-islanding according to local standard; maximum external AC overcurrent protection 25 A |
Certifications
| certifications | IEC/EN 62109-1, IEC/EN 62109-2, IEC 62477-1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12 |
Документи
product_page
FIMER Legacy products listing
product_page
REACT 2
quick_installation_guide
REACT2 Quick Installation Guide EN Rev D
Зафіксовані конфлікти
physical.weight_kg Resolved — kept current value
22 — stored value
< 22 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch08
electrical.number_of_pv_inputs Review required
2 — stored value
2 per MPPT — incoming package
Detected during import deep-enrich-pass2-2026-09-batch08
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | EU: FIMER's REACT 2 datasheet Rev E is the European edition; no separate North-American type code for REACT 2 is published on the page. |