Identity

category inverters
manufacturer FIMER
model TRIO-20.0-TL-OUTD
region EU
variant —

Electrical

ac_frequency_hz 50/60
ac_frequency_range_hz 47...53 / 57...63
ac_grid_connection_type Three-phase 3W+PE or 4W+PE
ac_voltage_range_v 320...480
altitude_max_m 2000
cec_efficiency_percent 98.0
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
communication_interfaces PVI-USB-RS232_485 (opt.); VSN300 Wifi Logger Card (opt.); VSN700 Data Logger (opt.)
contributory_fault_current_a 35.0
cooling_method Natural
dc_connection_type PV quick fit connector / screw terminal block on Standard and -S2 versions
dc_input_voltage_range_v 0.7 x Vstart...950 (min 200)
dc_switch_rating 40 A / 1000 V
euro_efficiency_pct 98.0
european_efficiency_percent 98.0
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
grid_standards CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11, EN 50438, RD 1699, RD 413, RD 661, P.O. 12.3, AS 4777, BDEW, NRS-097-2-1, MEA, IEC 61727, IEC 62116, Ordinul 30/2013, VFR 2014
isolation Transformerless (no galvanic isolation)
max_ac_current_a 33.0
max_ac_power_w 22000
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
max_apparent_power_va 22200
max_dc_input_power_per_mppt_w 12000
max_dc_power_per_mppt_w 12000
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
max_efficiency_pct 98.2
max_input_current_per_mppt_a 25.0
max_pv_voltage_v 1000
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
max_short_circuit_current_a 30.0
mppt_voltage_max_v 950
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
mppt_voltage_range_v 440...800
night_consumption_w < 0.6
noise_level_db 50 dB(A) @ 1 m
nominal_ac_voltage_v 400
number_of_mppt 2
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
number_of_pv_inputs 1 per MPPT (4 in -S2X, -S2F, -S1J, -S2J versions)
phase_count 3
FIMER string inverters catalogue index
power_factor_range > 0.995, adj. ± 0.9 with Pacr = 20.0 kW, ± 0.8 with max 22.2 kVA
rated_ac_power_w 20000
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
rated_dc_input_power_w 20750
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
rated_dc_input_voltage_v 620
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
rated_dc_power_w 20750
rated_dc_voltage_v 620
relative_humidity_pct 0...100 condensing
startup_voltage_v 430 суперечливе
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
thd_pct < 3
topology Transformerless

Physical / mechanical

depth_mm 292
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
dimensions_mm 1061 x 702 x 292
height_mm 1061
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
weight_kg 70.0 суперечливе
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
width_mm 702
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)

Environment

operating_temperature_max_c 60
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
operating_temperature_min_c -25
TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
operating_temperature_range_c -25...+60 (derating above 45)

Protection

max_external_ac_overcurrent_protection_a 50.0
protection_degree_ip IP65
protections DC reverse polarity protection (from limited current source); DC input overvoltage protection - 4 varistors per MPPT; DC surge arresters Type 2 (-S2X versions) / Type 1+2 (-S1J, -S2J versions); AC output overvoltage protection - 4 varistors; anti-islanding according to local standard; maximum external AC overcurrent protection 50.0 A

Certifications

certifications EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12

Документи

certificate TRIO-20.0/27.6-TL EU Declaration of Conformity Rev. 2021-01-14
compatibility_list Accessories compatibility matrix - Application Note EN Rev C
datasheet TRIO-20.0/27.6-TL Data sheet (FIMER_TRIO-20.0-27.6-TL-OUTD__EN_Rev_B)
installation_manual TRIO-20.0/27.6-TL-OUTD Product manual EN Rev G (M000001GG)
product_page FIMER string inverters catalogue index
product_page TRIO-20.0/27.6-TL
quick_start_guide TRIO-20.0/27.6-TL-OUTD Quick Installation Guide EN Rev E

Зафіксовані конфлікти

physical.weight_kg Review required
70.0 — stored value
< 70.0 — incoming package
Detected during import deep-enrich-pass2-2026-09-batch08
electrical.startup_voltage_v Review required
430 — stored value
430 (adj. 250...500) — incoming package
Detected during import deep-enrich-pass2-2026-09-batch08

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesEU: FIMER publishes this type code against EN 50549-1/-2, CEI 0-21, CEI 0-16, VDE-AR-N 4105-2018, G99-1 and an EU Declaration of Conformity, all listed on the product page. FIMER prints SEPARATE designations for other markets on the same page - TRIO-27.6(20.0)-TL-OUTD-S-US-480 (US) and TRIO-27.6-TL-OUTD-S2X-400-JP (Japan) - which are not created here because their own datasheet columns were not re