FoxESS AC1-3.0-E-G2
Official manufacturer GLOBAL перевірено 22 вересня 2026 р.
Identity
| category | inverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | G2 |
| manufacturer | FoxESS |
| market_version | EN datasheet; grid codes G98, G99, EN50549, AS/NZS 4777.2 |
| model | AC1-3.0-E-G2 |
| mpn | — |
| product_family | H1/AC1 |
| product_status | active |
| region | GLOBAL |
| release_year | — |
| series | AC1 (G2) |
| sku | — |
| variant | Single-phase AC-coupled battery (retrofit) inverter, no PV input |
Electrical
| ac_connection | — |
| ac_voltage_range | — |
| battery_capacity_range_kwh | — |
| battery_communication | CAN |
| battery_max_charge_current_a | 40 |
| battery_max_charge_power_w | — |
| battery_max_discharge_current_a | 40 |
| battery_max_discharge_power_w | — |
| battery_nominal_battery_voltage_v | — |
| battery_type | Lithium Battery (LFP) |
| battery_voltage_range_v | 80 ~ 480 |
| battery_wakeup_function |
Yes
H1(G2)/AC1(G2) Datasheet — PROTECTION, row 'Battery Wake-up Function' (single merged cell spanning all 14 model columns)
|
| eps_peak_power | — |
| eps_phase | single phase |
| eps_rated_power_va | — |
| eps_switchover_time_ms | <10 |
| eps_voltage | 220/230/240 V |
| european_efficiency_pct | 95.26 |
| external_transfer_switch_required | — |
| frequency_range_hz | — |
| inrush_current | — |
| max_ac_active_power_w | — |
| max_ac_current_a | — |
| max_apparent_power_va | — |
| max_backfeed_current_a | — |
| max_battery_discharge_efficiency_pct |
97.00 %
H1(G2)/AC1(G2) Datasheet — EFFICIENCY, row 'Max. Battery Discharge Efficiency (BAT to AC) (@full load) [%]' (single merged cell spanning all 14 model columns)
|
| max_dc_input_power_w | — |
| max_dc_voltage_v | — |
| max_efficiency_pct | 97.01 |
| max_input_current_per_mppt_a | — |
| max_output_fault_current_a | — |
| max_short_circuit_current_per_mppt_a | — |
| mppt_efficiency_pct | — |
| mppt_voltage_range_v | — |
| night_self_consumption_w | — |
| nominal_ac_voltage | 220/230/240 V |
| nominal_dc_voltage_v | — |
| nominal_frequency_hz | 50/60 |
| number_of_mppt | — |
| official_manual_url |
https://www.fox-ess.com/Public/Uploads/uploadfile/files/20251231/ENH1AC1G2ManualV1.0.8.pdf
FoxESS H1/AC1 | Hybrid Inverter
|
| official_product_url |
https://www.fox-ess.com/products/hybrid-inverter/h1-ac1
FoxESS H1/AC1 | Hybrid Inverter
|
| parallel_capability | 6 PCS |
| phase_count | 1 |
| power_factor_range | 1 (Adjustable 0.8 leading to 0.8 lagging) |
| rated_ac_power_w | 3000 |
| rated_mppt_voltage_range_v | — |
| rated_output_current_a |
13.6 A
H1(G2)/AC1(G2) Datasheet — AC INPUT AND OUTPUT (GRID), row 'Rated Output Current (per phase) [A]', column 'AC1-3.0-E-G2'
|
| startup_voltage_v | — |
| strings_per_mppt | — |
| thd_pct | <3 @rated power |
| topology |
Non-isolated
H1(G2)/AC1(G2) Datasheet — GENERAL DATA, row 'Topology' (single merged cell spanning all 14 model columns)
|
Physical / mechanical
| ac_terminal | — |
| cooling | Natural |
| dc_connector | — |
| depth_mm | 185 |
| dimensions_mm | 434 x 418 x 185 |
| display | LCD, App, Website |
| enclosure_material | — |
| height_mm | 418 |
| mounting | Wall-Mounted |
| noise_db | 35 |
| weight_kg | 22 |
| width_mm | 434 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP65 |
| max_altitude_m | 2000 |
| operating_temperature_c | -25 ~ 60 |
| pollution_degree | — |
| protective_class | — |
| relative_humidity_pct | 0 ~ 100 (no condensation) |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['WiFi', 'LAN (Optional)', '4G (Optional)', 'RS485', 'DRM', 'Ripple Control', 'USB', 'CAN', 'SG Ready'] |
| dry_contact | — |
| meter_interface | — |
| monitoring_portal | FoxCloud (App / Website) |
| protocols | [] |
Protection
| ac_overcurrent_overvoltage_protection |
Yes
H1(G2)/AC1(G2) Datasheet — PROTECTION, row 'AC Overcurrent/Overvoltage Protection' (single merged cell spanning all 14 model columns)
|
| ac_short_circuit_protection |
Yes
H1(G2)/AC1(G2) Datasheet — PROTECTION, row 'AC Short-circuit Protection' (single merged cell spanning all 14 model columns)
|
| anti_islanding | YES |
| arc_fault | AFCI: Optional |
| dc_switch | YES |
| insulation_monitoring | YES |
| overvoltage_category | — |
| rcmu | Residual Current Monitoring: YES |
| reverse_polarity | DC Reverse Polarity Protection: YES |
| surge_protection_ac | SPD Type III |
| surge_protection_dc | SPD Type II |
Certifications
| standards | ['EN 62109-1', 'EN 62109-2', 'G98', 'G99', 'EN50549', 'AS/NZS 4777.2'] |
Warranty & service
| conditions | — |
| extension_options | — |
| standard_years | — |
Документи
installation_manual
FoxESS H1(G2)/AC1(G2) SERIES User Manual V1.0.8
product_page
FoxESS H1/AC1 | Hybrid Inverter
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Battery Wake-up Function | YES |
| EPS OUTPUT - Max. Current (per phase) [A] | 11.4 / 13.6 / 16.7 / 18.2 / 20.9 / 22.7 / 27.3 |
| EPS OUTPUT - Max. Output Apparent Power [VA] | 2750 / 3600 / 4400 / 4800 / 5500 / 6000 / 7200 |
| EPS THDv (Linear Load) [%] | <2 |
| MPPT Operating Voltage Range [V] / Rated Output Current (per phase) [A] | 11.4 / 13.6 / 16.7 / 18.2 / 20.9 / 22.7 / 27.3 |
| Max. Battery Charge Efficiency (PV to BAT) (@full load) [%] | 98.50 |
| Max. Battery Discharge Efficiency (BAT to AC) (@full load) [%] | 97.00 |
| Max. Input Current [A] / Max. Output Current [A] | 12.5 / 15.0 / 18.4 / 20.0 / 23.0 / 25.0 / 30.0 |
| Max. Input Voltage [V] | 13.6 / 27.3 / 34.9 / 36.4 / 41.8 / 45.5 / 54.5 (values as printed in the extracted text, per column 2.5->6.0) |
| Max. Short-circuit Current [A] | 2500 / 3000 / 3680 / 4000 / 4600 / 5000 / 6000 |
| No. of MPP Trackers | read 1: 3000 / 3600 / 4400 / 4800 / 5500 / 6000 / 7200 ; read 2 (col1): 3000 |
| Rated Input Voltage [V] | read 1: 5500 / 3300 / 4048|3680 / 4400 / 5060 / 5500 / 6600 ; read 2: 2750 / 3300 / 4048|3680 / 4400 / 5060 / 5500 / 6600 |
| Standby consumption [W] | <15 |
| Start-up Input Voltage [V] | read 1: 5000 / 3000 / 3680 / 4000 / 4600 / 5000 / 6000 ; read 2: 2500 / 3000 / 3680 / 4000 / 4600 / 5000 / 6000 |
| Strings per MPP Tracker | read 1: 11.4 / 13.6 / 16.7 / 18.2 / 20.9 / 22.7 / 27.3 ; read 2 (col1): 3600 |
| Topology | Non-isolated |
| battery.communication | CAN |
| battery.max_charge_current_a | 40 |
| battery.max_charge_power_w | UNKNOWN |
| battery.max_discharge_current_a | 40 |
| battery.max_discharge_power_w | UNKNOWN |
| battery.nominal_battery_voltage_v | UNKNOWN |
| manufacturer_legal_entity_as_printed | Fox ESS |