Identity

category inverters
ean —
firmware {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'}
generation G2
manufacturer FoxESS
market_version EN datasheet; grid codes G98, G99, EN50549, AS/NZS 4777.2
model AC1-3.7-E-G2
mpn —
product_family H1/AC1
product_status active
region GLOBAL
release_year —
series AC1 (G2)
sku —
variant Single-phase AC-coupled battery (retrofit) inverter, no PV input

Electrical

ac_connection —
ac_voltage_range —
battery_capacity_range_kwh —
battery_communication CAN
battery_max_charge_current_a 40
battery_max_charge_power_w —
battery_max_discharge_current_a 40
battery_max_discharge_power_w —
battery_nominal_battery_voltage_v —
battery_type Lithium Battery (LFP)
battery_voltage_range_v 80 ~ 480
battery_wakeup_function Yes
H1(G2)/AC1(G2) Datasheet — PROTECTION, row 'Battery Wake-up Function' (single merged cell spanning all 14 model columns)
eps_peak_power —
eps_phase single phase
eps_rated_power_va —
eps_switchover_time_ms <10
eps_voltage 220/230/240 V
european_efficiency_pct 95.7
external_transfer_switch_required —
frequency_range_hz —
inrush_current —
max_ac_active_power_w —
max_ac_current_a —
max_apparent_power_va —
max_backfeed_current_a —
max_battery_discharge_efficiency_pct 97.00 %
H1(G2)/AC1(G2) Datasheet — EFFICIENCY, row 'Max. Battery Discharge Efficiency (BAT to AC) (@full load) [%]' (single merged cell spanning all 14 model columns)
max_dc_input_power_w —
max_dc_voltage_v —
max_efficiency_pct 97.08
max_input_current_per_mppt_a —
max_output_fault_current_a —
max_short_circuit_current_per_mppt_a —
mppt_efficiency_pct —
mppt_voltage_range_v —
night_self_consumption_w —
nominal_ac_voltage 220/230/240 V
nominal_dc_voltage_v —
nominal_frequency_hz 50/60
number_of_mppt —
official_manual_url https://www.fox-ess.com/Public/Uploads/uploadfile/files/20251231/ENH1AC1G2ManualV1.0.8.pdf
FoxESS H1/AC1 | Hybrid Inverter
official_product_url https://www.fox-ess.com/products/hybrid-inverter/h1-ac1
FoxESS H1/AC1 | Hybrid Inverter
parallel_capability 6 PCS
phase_count 1
power_factor_range 1 (Adjustable 0.8 leading to 0.8 lagging)
rated_ac_power_w 3680
rated_mppt_voltage_range_v —
rated_output_current_a 16.7 A
H1(G2)/AC1(G2) Datasheet — AC INPUT AND OUTPUT (GRID), row 'Rated Output Current (per phase) [A]', column 'AC1-3.7-E-G2'
startup_voltage_v —
strings_per_mppt —
thd_pct <3 @rated power
topology Non-isolated
H1(G2)/AC1(G2) Datasheet — GENERAL DATA, row 'Topology' (single merged cell spanning all 14 model columns)

Physical / mechanical

ac_terminal —
cooling Natural
dc_connector —
depth_mm 185
dimensions_mm 434 x 418 x 185
display LCD, App, Website
enclosure_material —
height_mm 418
mounting Wall-Mounted
noise_db 35
weight_kg 22
width_mm 434

Installation

cable_requirements —
commissioning —
installation_angle —
mounting_clearances —
torque —

Environment

ingress_protection IP65
max_altitude_m 2000
operating_temperature_c -25 ~ 60
pollution_degree —
protective_class —
relative_humidity_pct 0 ~ 100 (no condensation)
storage_temperature_c —

Interfaces & connectors

app —
communication ['WiFi', 'LAN (Optional)', '4G (Optional)', 'RS485', 'DRM', 'Ripple Control', 'USB', 'CAN', 'SG Ready']
dry_contact —
meter_interface —
monitoring_portal FoxCloud (App / Website)
protocols []

Protection

ac_overcurrent_overvoltage_protection Yes
H1(G2)/AC1(G2) Datasheet — PROTECTION, row 'AC Overcurrent/Overvoltage Protection' (single merged cell spanning all 14 model columns)
ac_short_circuit_protection Yes
H1(G2)/AC1(G2) Datasheet — PROTECTION, row 'AC Short-circuit Protection' (single merged cell spanning all 14 model columns)
anti_islanding YES
arc_fault AFCI: Optional
dc_switch YES
insulation_monitoring YES
overvoltage_category —
rcmu Residual Current Monitoring: YES
reverse_polarity DC Reverse Polarity Protection: YES
surge_protection_ac SPD Type III
surge_protection_dc SPD Type II

Certifications

standards ['EN 62109-1', 'EN 62109-2', 'G98', 'G99', 'EN50549', 'AS/NZS 4777.2']

Warranty & service

conditions —
extension_options —
standard_years —

Документи

datasheet H1(G2)/AC1(G2) Datasheet rev V.2.2
installation_manual FoxESS H1(G2)/AC1(G2) SERIES User Manual V1.0.8
product_page FoxESS H1/AC1 | Hybrid Inverter

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Battery Wake-up FunctionYES
EPS OUTPUT - Max. Current (per phase) [A]11.4 / 13.6 / 16.7 / 18.2 / 20.9 / 22.7 / 27.3
EPS OUTPUT - Max. Output Apparent Power [VA]2750 / 3600 / 4400 / 4800 / 5500 / 6000 / 7200
EPS THDv (Linear Load) [%]<2
MPPT Operating Voltage Range [V] / Rated Output Current (per phase) [A]11.4 / 13.6 / 16.7 / 18.2 / 20.9 / 22.7 / 27.3
Max. Battery Charge Efficiency (PV to BAT) (@full load) [%]98.50
Max. Battery Discharge Efficiency (BAT to AC) (@full load) [%]97.00
Max. Input Current [A] / Max. Output Current [A]12.5 / 15.0 / 18.4 / 20.0 / 23.0 / 25.0 / 30.0
Max. Input Voltage [V]13.6 / 27.3 / 34.9 / 36.4 / 41.8 / 45.5 / 54.5 (values as printed in the extracted text, per column 2.5->6.0)
Max. Short-circuit Current [A]2500 / 3000 / 3680 / 4000 / 4600 / 5000 / 6000
No. of MPP Trackersread 1: 3000 / 3600 / 4400 / 4800 / 5500 / 6000 / 7200 ; read 2 (col1): 3000
Rated Input Voltage [V]read 1: 5500 / 3300 / 4048|3680 / 4400 / 5060 / 5500 / 6600 ; read 2: 2750 / 3300 / 4048|3680 / 4400 / 5060 / 5500 / 6600
Standby consumption [W]<15
Start-up Input Voltage [V]read 1: 5000 / 3000 / 3680 / 4000 / 4600 / 5000 / 6000 ; read 2: 2500 / 3000 / 3680 / 4000 / 4600 / 5000 / 6000
Strings per MPP Trackerread 1: 11.4 / 13.6 / 16.7 / 18.2 / 20.9 / 22.7 / 27.3 ; read 2 (col1): 3600
TopologyNon-isolated
battery.communicationCAN
battery.max_charge_current_a40
battery.max_charge_power_wUNKNOWN
battery.max_discharge_current_a40
battery.max_discharge_power_wUNKNOWN
battery.nominal_battery_voltage_vUNKNOWN
manufacturer_legal_entity_as_printedFox ESS