База знань ›
Inverters
Official manufacturer
GLOBAL
перевірено 14 вересня 2026 р.
PRODUCT PHOTO · GoodWe
Identity
category
inverters
ean
—
firmware
{'documented_version': 'UNKNOWN', 'constraints': 'IoT accessory compatibility is gated on firmware level - see documented_relationships.'}
generation
G3 (-30)
manufacturer
GoodWe
market_version
EU / global EN documentation; three phase 220/380, 230/400, 240/415 V
model
GW10K-SDT-30
mpn
GW10K-SDT-30
product_family
SDT
product_status
active
region
GLOBAL
release_year
—
series
SDT G3
sku
—
Electrical
ac_connection
Three phase
ac_voltage_range
180 ~ 280
european_efficiency_pct
98.0
frequency_range_hz
45 ~ 55 / 55 ~ 65
inrush_current
—
max_ac_active_power_w
11000
max_ac_current_a
16.7
max_apparent_power_va
10000
max_backfeed_current_a
—
max_dc_input_power_w
—
max_dc_voltage_v
1100
max_efficiency_pct
98.5
max_input_current_per_mppt_a
22
max_output_fault_current_a
—
max_short_circuit_current_per_mppt_a
27.5
mppt_efficiency_pct
—
mppt_voltage_range_v
140 ~ 1000
night_self_consumption_w
<1
nominal_ac_voltage
220/380, 230/400, 240/415, 3L/N/PE or 3L/PE
nominal_dc_voltage_v
600
nominal_frequency_hz
50 / 60
number_of_mppt
2
phase_count
3
power_factor_range
~1 (0.8 leading to 0.8 lagging)
rated_ac_power_w
10000
rated_mppt_voltage_range_v
—
startup_voltage_v
160
strings_per_mppt
1
thd_pct
<3%
Physical / mechanical
ac_terminal
OT/DT terminal (Max. 10mm2)
cooling
Natural Convection
dc_connector
MC4 (4 ~ 6mm2)
depth_mm
210
dimensions_mm
491 x 392 x 210
display
LED, LCD (Optional), WLAN + APP
enclosure_material
—
height_mm
392
mounting
—
noise_db
<30
weight_kg
15.1
width_mm
491
Installation
cable_requirements
—
commissioning
—
installation_angle
—
mounting_clearances
—
torque
—
Environment
ingress_protection
IP66
max_altitude_m
4000
operating_temperature_c
-30 ~ +60
pollution_degree
—
protective_class
—
relative_humidity_pct
0 ~ 100%
storage_temperature_c
—
Interfaces & connectors
app
SolarGo (GoodWe smartphone app; named on the product page)
communication
['RS485', 'WiFi + LAN + Bluetooth', '4G + Bluetooth (Optional)']
dry_contact
—
meter_interface
—
monitoring_portal
—
protocols
['Modbus-RTU (SunSpec Compliant)', 'Modbus-TCP']
Protection
anti_islanding
—
arc_fault
AFCI: Optional
dc_switch
Integrated
insulation_monitoring
—
overvoltage_category
—
rcmu
—
reverse_polarity
—
surge_protection_ac
Type III (Type II Optional)
surge_protection_dc
Type III (Type II Optional)
Warranty & service
conditions
No warranty term is printed on the datasheet or the product page; not inferred.
extension_options
—
standard_years
—
Документи
other
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
GoodWe SDT G3 Series download index ('More Files') — знайдено, не отримано
rev UNKNOWN
user-manual
{# Located but never retrieved: listed, but deliberately not linked, and it
backs no stored value. #}
GoodWe SDT G3 Series User Manual — знайдено, не отримано
rev UNKNOWN
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
Max. AC Apparent Power 11.0 kVA
Nominal Output Power / Apparent / Max AC Active / Max AC Apparent printed in kW / kVA on the SDT G3 datasheet, not in W / VA
Topology Non-isolated
identity.region_as_printed EU / global EN
withheld:pv.mppt_topology_notation "2 MPP trackers / 1 string(s) per MPPT, as printed"