⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

Hoymiles HIT-8L-G3

Побудувати систему з цим продуктом

Official manufacturer GLOBAL перевірено 25 вересня 2026 р.

Identity

category inverters
manufacturer Hoymiles
model HIT-8L-G3
region GLOBAL

Electrical

backup_max_apparent_power_va 16000
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
backup_max_continuous_current_a 12.2
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
backup_output True
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
backup_rated_power_w 8000
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
backup_switch_time_ms 10
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
battery_supported True
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
battery_voltage_class LV
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
battery_voltage_max_v 60
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
battery_voltage_min_v 40
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
grid_frequency_hz [50, 60]
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
has_internal_pv_input True
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_ac_output_current_a 13.3
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_ac_power_w 8800
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_charge_current_a 190
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_discharge_current_a 190
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_input_current_per_mppt_a [20.0, 20.0, 20.0]
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_pv_voltage_v 1000
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
max_short_circuit_current_per_mppt_a [30.0, 30.0, 30.0]
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
mppt_voltage_max_v 900
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
mppt_voltage_min_v 150
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
nominal_grid_voltage_v 400
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
number_of_mppt 3
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
number_of_pv_inputs 3
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
phase_count 3
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
rated_ac_power_w 8000
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
recommended_max_pv_power_w 16000
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
startup_voltage_v 150
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
strings_per_mppt_distribution [1, 1, 1]
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0

Physical / mechanical

dimensions_mm 539 x 696 x 232
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
weight_kg 41
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0

Interfaces & connectors

communications ['RS485', 'Wi-Fi (optional)', 'WL (optional)', '4G (optional)', 'CAN (battery)']
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
documented_ports [{'port_role': 'GRID', 'port_label_from_manual': 'AC Input and Output (On-grid)', 'port_type': 'AC terminal', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'quantity': 1, 'limits': {'nominal_voltage_v': 400, 'max_output_current_a': 13.3}, 'document': 0, 'page': 'Specifications, AC Input and Output (On-grid)', 'quote': 'Grid form: 3L/N/PE; Rated AC output voltage/Range (V): 380/400, 266-480; Max. output current (A): HIT-8L-G3 column = 13.3'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'AC Output (Back-up)', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 1, 'limits': {'max_continuous_output_current_a': 12.2, 'max_continuous_ac_bypass_current_a': 50}, 'document': 0, 'page': 'Specifications, AC Output (Back-up)', 'quote': 'AC Output (Back-up) - Max. continuous output current (A): HIT-8L-G3 column = 12.2; Max. continuous AC bypass current (A): 50'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 1, 'limits': {'voltage_min_v': 40, 'voltage_max_v': 60, 'max_charge_current_a': 190, 'max_discharge_current_a': 190}, 'document': 0, 'page': 'Specifications, Battery', 'quote': 'Battery voltage range (V): 40-60; Max. charge/discharge current (A): HIT-8L-G3 column = 190/190'}, {'port_role': 'CAN', 'port_label_from_manual': 'Battery - Communication', 'port_type': 'CAN', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications, Battery', 'quote': 'Battery - Communication: CAN'}, {'port_role': 'RS485', 'port_label_from_manual': 'Communication', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications, General', 'quote': 'Communication: RS485, Wi-Fi/WL/4G (optional)'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'Digital input/output', 'port_type': 'digital input', 'direction': 'input', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Specifications, General', 'quote': 'Digital input/output: DRM, 2 x DI, 2 x DO'}, {'port_role': 'DIGITAL_OUT', 'port_label_from_manual': 'Digital input/output', 'port_type': 'digital output', 'direction': 'output', 'electrical_domain': 'communication', 'quantity': 2, 'document': 0, 'page': 'Specifications, General', 'quote': 'Digital input/output: DRM, 2 x DI, 2 x DO'}, {'port_role': 'MPPT1', 'port_label_from_manual': 'PV Input', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'limits': {'max_input_current_a': 20.0, 'max_short_circuit_current_a': 30.0, 'max_input_voltage_v': 1000, 'mppt_voltage_min_v': 150, 'mppt_voltage_max_v': 900}, 'document': 0, 'page': 'Specifications, PV Input', 'quote': 'MPPT number/Max. input strings number: HIT-8L-G3 column = 3/3; Max. input current (A): 20/20/20; Max. short circuit current (A): 30/30/30'}, {'port_role': 'MPPT2', 'port_label_from_manual': 'PV Input', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'limits': {'max_input_current_a': 20.0, 'max_short_circuit_current_a': 30.0, 'max_input_voltage_v': 1000, 'mppt_voltage_min_v': 150, 'mppt_voltage_max_v': 900}, 'document': 0, 'page': 'Specifications, PV Input', 'quote': 'MPPT number/Max. input strings number: HIT-8L-G3 column = 3/3; Max. input current (A): 20/20/20; Max. short circuit current (A): 30/30/30'}, {'port_role': 'MPPT3', 'port_label_from_manual': 'PV Input', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'limits': {'max_input_current_a': 20.0, 'max_short_circuit_current_a': 30.0, 'max_input_voltage_v': 1000, 'mppt_voltage_min_v': 150, 'mppt_voltage_max_v': 900}, 'document': 0, 'page': 'Specifications, PV Input', 'quote': 'MPPT number/Max. input strings number: HIT-8L-G3 column = 3/3; Max. input current (A): 20/20/20; Max. short circuit current (A): 30/30/30'}]

Protection

ingress_protection IP66
Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0

Документи

datasheet Hoymiles HIT-(5-20)L-G3 / HIT-(5-20)L-G3S datasheet (Global EN rev 1.5)
datasheet Three-phase Hybrid Inverter HIT-(5-20)L-G3 Series Datasheet, Region: Global, REV1.0
product_page HIT-(5-20)L-G3 - All Products - Hoymiles

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesThe datasheet header prints 'Region: Global'. One electrical specification worldwide: 3L/N/PE, rated AC 380/400 V, 50/60 Hz, certified to IEC 61727, IEC 62116, EN 50549 and VDE-AR-N 4105.