KOSTAL Solar Electric GmbH PIKO CI 100
Official manufacturer EU перевірено 22 вересня 2026 р.
Identity
| category | inverters |
| ean | — |
| firmware | {'documented_version': 'UNKNOWN', 'constraints': 'UNKNOWN'} |
| generation | — |
| manufacturer | KOSTAL Solar Electric GmbH |
| market_version | EU (VDE-AR-N 4105:2018, EN 50549-1/-2; EN datasheet DOC03181998) |
| model | PIKO CI 100 |
| mpn | — |
| product_family | PIKO CI |
| product_status | active |
| region | EU |
| release_year | — |
| series | PIKO CI |
| sku | — |
Electrical
| ac_connection | M12 (bolt) |
| ac_voltage_range | 322 - 520 V |
| battery_type | n/a - PV-only string inverter, no battery input printed |
| eps_rated_power_va | n/a - no backup function printed in this datasheet |
| european_efficiency_pct | 97.8 |
| frequency_range_hz | 45 - 55 |
| inrush_current | — |
| max_ac_active_power_w | 100000 |
| max_ac_current_a | 168.8 |
| max_apparent_power_va | 111000 |
| max_backfeed_current_a | — |
| max_dc_input_power_w | — |
| max_dc_voltage_v | 1100 |
| max_efficiency_pct | 98.3 |
| max_input_current_per_mppt_a | MPPT 1-3: 40 A; MPPT 4-6: 32 A (values for MPPT 7-8 not captured) |
| max_output_fault_current_a | — |
| max_recommended_pv_power_kwp | 150 |
| max_short_circuit_current_per_mppt_a | MPPT 1-3: 50 A; MPPT 4-6: 45 A; total max. DC short-circuit current 375 A |
| mppt_efficiency_pct | — |
| mppt_voltage_range_v | 540 - 800 V |
| night_self_consumption_w | < 10 |
| nominal_ac_voltage | 3N~, 230/400 V, 50 Hz |
| nominal_dc_voltage_v | 600 |
| nominal_frequency_hz | 50 |
| number_of_dc_inputs | 16 |
| number_of_mppt | 8 |
| official_manual_url |
https://www.kostal-solar-electric.com/fileadmin/downloadcenter/kse/BA/PIKO-CI-100/PIKO-CI-100_BA_en.pdf
Operating manual PIKO CI 100 kW solar inverter (EN)
|
| official_product_url |
https://www.kostal-solar-electric.com/en/products/solar-inverter/piko-ci-100/
Operating manual PIKO CI 100 kW solar inverter (EN)
|
| phase_count | 3 |
| power_factor_range | 0.8 ... 1 ... 0.8 |
| rated_ac_current_a | 145 |
| rated_ac_power_w | 100000 |
| rated_mppt_voltage_range_v | 540 - 800 V |
| startup_voltage_v | 250 |
| strings_per_mppt | — |
| thd_pct | < 3 |
Physical / mechanical
| ac_terminal | M12 (bolt) |
| cooling | regulated fans (max. 640 m3/h) |
| dc_connector | Amphenol plug H4 |
| depth_mm | 365 |
| dimensions_mm | 936 x 678 x 365 (W x H x D) |
| display | — |
| enclosure_material | — |
| height_mm | 678 |
| mounting | — |
| noise_db | 65 |
| weight_kg | 93 |
| width_mm | 936 |
Installation
| cable_requirements | — |
| commissioning | — |
| installation_angle | — |
| mounting_clearances | — |
| torque | — |
Environment
| ingress_protection | IP 66 |
| max_altitude_m | 4000 |
| operating_temperature_c | -25 to +60 |
| pollution_degree | — |
| protective_class | I |
| relative_humidity_pct | 0 - 100 |
| storage_temperature_c | — |
Interfaces & connectors
| app | — |
| communication | ['2 x Ethernet LAN TCP/IP (RJ45)', '2 x RS485', 'WiFi', 'Bluetooth'] |
| dry_contact | — |
| meter_interface | KOSTAL Smart Energy Meter |
| monitoring_portal | KOSTAL Solar Portal |
| protocols | ['Modbus RTU'] |
Protection
| anti_islanding | — |
| arc_fault | DC arc detection (AFCI) |
| dc_switch | Integrated KOSTAL Smart AC Switch |
| insulation_monitoring | — |
| overvoltage_category | Input: II / Output: III |
| rcmu | Internal operator protection in accordance with EN 62109-2, RCCB type B |
| reverse_polarity | — |
| surge_protection_ac | AC overvoltage protection Type 2 (exchangeable) |
| surge_protection_dc | DC overvoltage protection Type 2 (exchangeable) |
Certifications
| standards | ['EN 62109-1', 'EN 62109-2', 'IEC 62920', 'VDE-AR-N 4105:2018', 'VDE V 0124-100', 'PO12.2', 'RD 244:2019', 'UNE 217001', 'EN 50549-1*', 'EN 50549-2*', 'CEI 0-16 2019', 'CEI 0-21 2019 >11,08 kW', 'UK G99/1-4 LV', 'IRR-DCC MV 2015', 'IEC 61727', 'IEC 62116'] |
Warranty & service
| conditions | KOSTAL Smart Warranty activation required |
| extension_options | 5 years extension (paid option) |
| standard_years | 5 |
Документи
product_page
KOSTAL official product page - PIKO CI 100
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| Max. DC short-circuit current (ISC_PV) | 375 A total (MPPT 1-3: 50 A / MPPT 4-8: 45 A) |
| Max. input current (IDCmax) per MPPT | MPPT 1-3: 40 A / MPPT 4-8: 32 A |
| Max. input current per MPP tracker | MPPT 1-3: 40 A / MPPT 4-6: 32 A |