Identity

category inverters
manufacturer KSTAR
model KAC100DP2
region GLOBAL
variant —

Electrical

ac_configuration 3L+PE+N
User Manual_KAC80-125DP2_EN_V2.0
ac_voltage_range_v 340-440
User Manual_KAC80-125DP2_EN_V2.0
backup_output True
User Manual_KAC80-125DP2_EN_V2.0
battery_communication ['CAN', 'RS485']
User Manual_KAC80-125DP2_EN_V2.0
battery_port True
User Manual_KAC80-125DP2_EN_V2.0
battery_voltage_max_v 950
User Manual_KAC80-125DP2_EN_V2.0
battery_voltage_min_v 200
User Manual_KAC80-125DP2_EN_V2.0
cooling Intelligent air cooling
User Manual_KAC80-125DP2_EN_V2.0
display LED
User Manual_KAC80-125DP2_EN_V2.0
frequency_hz 50/60
User Manual_KAC80-125DP2_EN_V2.0
generator_input True
User Manual_KAC80-125DP2_EN_V2.0
hybrid True
BluePulse Liquid-cooling 80-125kW / 208-260kWh
inverter_type three-phase hybrid PV + storage inverter
KSTAR Datasheet KAC(80~125)DP2 / BC208DLE / BC260DLE V5
isolation Non-isolated
User Manual_KAC80-125DP2_EN_V2.0
max_ac_current_a 227 суперечливе
User Manual_KAC80-125DP2_EN_V2.0
max_ac_power_kw 100
User Manual_KAC80-125DP2_EN_V2.0
max_apparent_power_va 110000
User Manual_KAC80-125DP2_EN_V2.0
max_efficiency_percent 98
KSTAR Datasheet KAC(80~125)DP2 / BC208DLE / BC260DLE V5
max_pv_current_per_mppt_a 45
User Manual_KAC80-125DP2_EN_V2.0
max_pv_power_w 200000
User Manual_KAC80-125DP2_EN_V2.0
max_pv_voltage_v 1000
User Manual_KAC80-125DP2_EN_V2.0
max_short_circuit_current_per_mppt_a 60
User Manual_KAC80-125DP2_EN_V2.0
mppt_voltage_max_v 950
User Manual_KAC80-125DP2_EN_V2.0
mppt_voltage_min_v 250
User Manual_KAC80-125DP2_EN_V2.0
nominal_ac_voltage_v 230/400 (also 220/380)
User Manual_KAC80-125DP2_EN_V2.0
number_of_mppt 8
User Manual_KAC80-125DP2_EN_V2.0
overvoltage_category_grid OVC III
User Manual_KAC80-125DP2_EN_V2.0
parallel_supported True
User Manual_KAC80-125DP2_EN_V2.0
phase_count 3
User Manual_KAC80-125DP2_EN_V2.0
power_factor >0.99
User Manual_KAC80-125DP2_EN_V2.0
pv_input True
User Manual_KAC80-125DP2_EN_V2.0
rated_ac_current_a 145
User Manual_KAC80-125DP2_EN_V2.0
rated_ac_power_kw 100
User Manual_KAC80-125DP2_EN_V2.0
rated_ac_power_w 100000
User Manual_KAC80-125DP2_EN_V2.0
rated_pv_power_w 200000
User Manual_KAC80-125DP2_EN_V2.0
relative_humidity_percent 0-100
User Manual_KAC80-125DP2_EN_V2.0
strings_per_mppt 2
User Manual_KAC80-125DP2_EN_V2.0
thd_percent 3
User Manual_KAC80-125DP2_EN_V2.0

Physical / mechanical

dimensions_mm 1120 x 760 x 365
User Manual_KAC80-125DP2_EN_V2.0
weight_kg 135
User Manual_KAC80-125DP2_EN_V2.0

Environment

ip_rating IP66
User Manual_KAC80-125DP2_EN_V2.0
max_altitude_m 3000
User Manual_KAC80-125DP2_EN_V2.0
operating_temperature_max_c 60
User Manual_KAC80-125DP2_EN_V2.0
operating_temperature_min_c -25
User Manual_KAC80-125DP2_EN_V2.0

Interfaces & connectors

documented_ports [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV+', 'port_type': 'DC terminal', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'PV+'}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV-', 'port_type': 'DC terminal', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'PV-'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'BAT+', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BAT+'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'BAT-', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BAT-'}, {'port_role': 'GRID', 'port_label_from_manual': 'L1, L2, L3, N, PE', 'port_type': 'AC terminal block', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'L1, L2, L3, N, PE'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'BACK-UPLOAD', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BACK-UPLOAD'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC terminal', 'direction': 'input', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'GEN'}, {'port_role': 'AUX', 'port_label_from_manual': 'BAT-AC-POWER', 'port_type': 'AC auxiliary supply', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BAT-AC-POWER'}, {'port_role': 'PARALLEL_OUT', 'port_label_from_manual': 'PARA1', 'port_type': 'parallel communication', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'PARA1'}, {'port_role': 'RS485', 'port_label_from_manual': 'COM (RS485/CAN)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'COM (RS485/CAN)'}, {'port_role': 'CAN', 'port_label_from_manual': 'COM (RS485/CAN)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'COM (RS485/CAN)'}, {'port_role': 'DRY_CONTACT', 'port_label_from_manual': 'DRY', 'port_type': 'dry contact', 'direction': 'input', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'DRY'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DRM', 'port_type': 'demand response mode interface', 'direction': 'input', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'DRM'}] суперечливе

Protection

protection_class Class I
User Manual_KAC80-125DP2_EN_V2.0

Документи

certificate KAC125DP2 TOR Stromerzeugungsanlagen Typ A
datasheet Datasheet_KAC(80~125)DP2-BC208DLE_BC260DLE_EN_V5
datasheet KSTAR Datasheet KAC(80~125)DP2 / BC208DLE / BC260DLE V5
product_page BluePulse Liquid-cooling 80-125kW / 208-260kWh
user_manual User Manual_KAC80-125DP2_EN_V2.0
user_manual User Manual_KAC80-125DP2_EN_V2.0

Зафіксовані конфлікти

interfaces.documented_ports Review required
[{'port_role': 'PV_IN', 'port_label_from_manual': 'PV+', 'port_type': 'DC terminal', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'PV+'}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV-', 'port_type': 'DC terminal', 'direction': 'input', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'PV-'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'BAT+', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BAT+'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'BAT-', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BAT-'}, {'port_role': 'GRID', 'port_label_from_manual': 'L1, L2, L3, N, PE', 'port_type': 'AC terminal block', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'L1, L2, L3, N, PE'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'BACK-UPLOAD', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BACK-UPLOAD'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC terminal', 'direction': 'input', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'GEN'}, {'port_role': 'AUX', 'port_label_from_manual': 'BAT-AC-POWER', 'port_type': 'AC auxiliary supply', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'BAT-AC-POWER'}, {'port_role': 'PARALLEL_OUT', 'port_label_from_manual': 'PARA1', 'port_type': 'parallel communication', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'PARA1'}, {'port_role': 'RS485', 'port_label_from_manual': 'COM (RS485/CAN)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'COM (RS485/CAN)'}, {'port_role': 'CAN', 'port_label_from_manual': 'COM (RS485/CAN)', 'port_type': 'communication connector', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'COM (RS485/CAN)'}, {'port_role': 'DRY_CONTACT', 'port_label_from_manual': 'DRY', 'port_type': 'dry contact', 'direction': 'input', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'DRY'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DRM', 'port_type': 'demand response mode interface', 'direction': 'input', 'electrical_domain': 'communication', 'document': 0, 'page': 'Electrical connection / terminal definitions', 'quote': 'DRM'}] — stored value
[{'port_role': 'CAN', 'port_label_from_manual': 'CAN', 'port_type': 'CAN bus', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Appendix I Technical Parameters', 'quote': 'Communication interface CAN/RS485'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'RS485', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'Appendix I Technical Parameters', 'quote': 'Communication interface CAN/RS485'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'Battery', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'dc', 'document': 0, 'page': 'Appendix I Technical Parameters', 'quote': 'Battery voltage range 200~950V d.c.'}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV input', 'port_type': 'DC terminal', 'direction': 'input', 'electrical_domain': 'dc', 'document': 0, 'page': 'Appendix I Technical Parameters', 'quote': 'Number of MPPTs 8; Maximum strings per MPPT 2'}] — incoming package
Detected during import deep-enrich-2026-09-batch19
electrical.max_ac_current_a Review required
227 — stored value
145 — KAC100DP2 Max AC output current 145 A
Detected during import deep-enrich-2026-09-batch19

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesKSTAR (Shenzhen Kstar Science & Technology Co., Ltd., China), documented on KSTAR New Energy's English global site. A German grid-code certificate (TOR Stromerzeugungsanlagen Typ A) is published for KAC125DP2, so the line is sold into the EU as well.