LuxpowerTek GEN PRO-LB-EU 10K
Official manufacturer EU перевірено 23 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | LuxpowerTek |
| model | GEN PRO-LB-EU 10K |
| region | EU |
Electrical
| backup_output |
True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| backup_surge |
2 x rated power for 1s
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| backup_switching_time_ms |
7
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| battery_nominal_voltage_v |
48
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| battery_supported |
True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| battery_voltage_class |
LV
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| battery_voltage_max_v |
60
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| battery_voltage_min_v |
48
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| eu_efficiency_pct |
96.0
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| generator_input |
True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| grid_frequency_hz |
[50, 60]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| has_internal_pv_input |
True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_ac_input_current_a |
100
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_ac_input_power_w |
23000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_charge_power_w |
10000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_continuous_ac_passthrough_current_a |
100
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_discharge_power_w |
10000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_efficiency_pct |
97.3
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_input_current_per_mppt_a |
[20, 20, 20]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_parallel_units |
16
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_pv_voltage_v |
530
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| max_short_circuit_current_per_mppt_a |
[32, 32, 32]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| mppt_voltage_max_v |
425
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| mppt_voltage_min_v |
60
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| nominal_grid_voltage_v |
230
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| number_of_mppt |
3
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| number_of_pv_inputs |
3
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| parallel_supported |
True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| phase_count |
1
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| rated_ac_output_current_a |
43.5
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| rated_ac_power_w |
10000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| rated_pv_input_voltage_v |
360
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| startup_voltage_v |
50
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| strings_per_mppt_distribution |
[1, 1, 1]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
Physical / mechanical
| weight_kg |
30.2
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
Interfaces & connectors
| communications |
['LCD', 'RS485', 'WiFi', 'CAN']
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
| documented_ports | [{'port_role': 'MPPT1', 'port_label_from_manual': 'PV1', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_input_current_a': 20, 'max_short_circuit_current_a': 32, 'document': 0, 'page': 'Specifications — Input (PV DC)', 'quote': 'Number of independent MPPT inputs "3 / (1:1:1)"; Max. PV input current per MPPT (A) "20 / 20 / 20"; Max. PV short-circuit current input per MPPT (A) "32 / 32 / 32"'}, {'port_role': 'MPPT2', 'port_label_from_manual': 'PV2', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_input_current_a': 20, 'max_short_circuit_current_a': 32, 'document': 0, 'page': 'Specifications — Input (PV DC)', 'quote': 'Number of independent MPPT inputs "3 / (1:1:1)"; Max. PV input current per MPPT (A) "20 / 20 / 20"; Max. PV short-circuit current input per MPPT (A) "32 / 32 / 32"'}, {'port_role': 'MPPT3', 'port_label_from_manual': 'PV3', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_input_current_a': 20, 'max_short_circuit_current_a': 32, 'document': 0, 'page': 'Specifications — Input (PV DC)', 'quote': 'Number of independent MPPT inputs "3 / (1:1:1)"; Max. PV input current per MPPT (A) "20 / 20 / 20"; Max. PV short-circuit current input per MPPT (A) "32 / 32 / 32"'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery', 'port_type': 'DC battery', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 1, 'voltage_min_v': 48, 'voltage_max_v': 60, 'document': 0, 'page': 'Specifications — Battery', 'quote': 'Rated battery voltage (V) "48"; Battery voltage range (V) "48 ~ 60"'}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid', 'port_type': 'AC single-phase', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 100, 'document': 0, 'page': 'Specifications — Grid', 'quote': 'Rated AC voltage (V) "230"; Max. AC input current (A) "100"; Max continuous AC passthrough current (A) "100"'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC single-phase', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 80, 'max_power_w': 18400, 'document': 0, 'page': 'Specifications — GEN', 'quote': 'Rated GEN voltage (V) "230"; Rated GEN input current (A) "80"; Rated GEN input power (W) "18400"'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'UPS', 'port_type': 'AC single-phase', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': 'Specifications — UPS', 'quote': 'Rated output voltage (V) "230"; Switching time "7ms"'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'serial', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications — General', 'quote': 'Display & Communication interface: "LCD, RS485, Wifi, CAN"'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN', 'port_type': 'serial', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications — General', 'quote': 'Display & Communication interface: "LCD, RS485, Wifi, CAN"'}] |
Protection
| ingress_protection |
IP66
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
|
Документи
product_page
GEN PRO-LB-EU 8-12K Hybrid Solar Inverter
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | Model code carries the -EU suffix; certification list EN62109-1/-2, EN61000, EN50549-1/-10, UNE27001/UNE27002, G99, G100 — European 230 V single-phase product. |