Identity

category inverters
manufacturer LuxpowerTek
model GEN PRO-LB-EU 12K
region EU

Electrical

backup_output True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
backup_surge 2 x rated power for 1s
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
backup_switching_time_ms 7
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
battery_nominal_voltage_v 48
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
battery_supported True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
battery_voltage_class LV
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
battery_voltage_max_v 60
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
battery_voltage_min_v 48
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
eu_efficiency_pct 96.0
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
generator_input True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
grid_frequency_hz [50, 60]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
has_internal_pv_input True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_ac_input_current_a 100
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_ac_input_power_w 23000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_charge_current_a 270
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_charge_power_w 12000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_continuous_ac_passthrough_current_a 100
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_discharge_current_a 270
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_discharge_power_w 12000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_efficiency_pct 97.3
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_input_current_per_mppt_a [20, 20, 20]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_parallel_units 16
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_pv_voltage_v 530
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
max_short_circuit_current_per_mppt_a [32, 32, 32]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
mppt_voltage_max_v 425
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
mppt_voltage_min_v 60
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
nominal_grid_voltage_v 230
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
number_of_mppt 3
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
number_of_pv_inputs 3
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
parallel_supported True
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
phase_count 1
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
rated_ac_output_current_a 52.0
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
rated_ac_power_w 12000
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
rated_pv_input_voltage_v 360
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
startup_voltage_v 50
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
strings_per_mppt_distribution [1, 1, 1]
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)

Interfaces & connectors

communications ['LCD', 'RS485', 'WiFi', 'CAN']
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
documented_ports [{'port_role': 'MPPT1', 'port_label_from_manual': 'PV1', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_input_current_a': 20, 'max_short_circuit_current_a': 32, 'document': 0, 'page': 'Specifications — Input (PV DC)', 'quote': 'Number of independent MPPT inputs "3 / (1:1:1)"; Max. PV input current per MPPT (A) "20 / 20 / 20"; Max. PV short-circuit current input per MPPT (A) "32 / 32 / 32"'}, {'port_role': 'MPPT2', 'port_label_from_manual': 'PV2', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_input_current_a': 20, 'max_short_circuit_current_a': 32, 'document': 0, 'page': 'Specifications — Input (PV DC)', 'quote': 'Number of independent MPPT inputs "3 / (1:1:1)"; Max. PV input current per MPPT (A) "20 / 20 / 20"; Max. PV short-circuit current input per MPPT (A) "32 / 32 / 32"'}, {'port_role': 'MPPT3', 'port_label_from_manual': 'PV3', 'port_type': 'DC PV input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 1, 'max_input_current_a': 20, 'max_short_circuit_current_a': 32, 'document': 0, 'page': 'Specifications — Input (PV DC)', 'quote': 'Number of independent MPPT inputs "3 / (1:1:1)"; Max. PV input current per MPPT (A) "20 / 20 / 20"; Max. PV short-circuit current input per MPPT (A) "32 / 32 / 32"'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery', 'port_type': 'DC battery', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 1, 'voltage_min_v': 48, 'voltage_max_v': 60, 'document': 0, 'page': 'Specifications — Battery', 'quote': 'Rated battery voltage (V) "48"; Battery voltage range (V) "48 ~ 60"'}, {'port_role': 'GRID', 'port_label_from_manual': 'Grid', 'port_type': 'AC single-phase', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 100, 'document': 0, 'page': 'Specifications — Grid', 'quote': 'Rated AC voltage (V) "230"; Max. AC input current (A) "100"; Max continuous AC passthrough current (A) "100"'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN', 'port_type': 'AC single-phase', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 80, 'max_power_w': 18400, 'document': 0, 'page': 'Specifications — GEN', 'quote': 'Rated GEN voltage (V) "230"; Rated GEN input current (A) "80"; Rated GEN input power (W) "18400"'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'UPS', 'port_type': 'AC single-phase', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 1, 'document': 0, 'page': 'Specifications — UPS', 'quote': 'Rated output voltage (V) "230"; Switching time "7ms"'}, {'port_role': 'RS485', 'port_label_from_manual': 'RS485', 'port_type': 'serial', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications — General', 'quote': 'Display & Communication interface: "LCD, RS485, Wifi, CAN"'}, {'port_role': 'CAN', 'port_label_from_manual': 'CAN', 'port_type': 'serial', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'quantity': 1, 'document': 0, 'page': 'Specifications — General', 'quote': 'Display & Communication interface: "LCD, RS485, Wifi, CAN"'}]

Protection

ingress_protection IP66
GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)

Документи

datasheet GEN PRO-LB-EU 8-12K (Single-Phase) HYBRID SERIES — Datasheet (EN, 2026.07.29)
manual GEN3 / GEN PRO Series User Manual (EN, 2026.07.24)
product_page GEN PRO-LB-EU 8-12K Hybrid Solar Inverter
product_page LuxpowerTek EU Series Inverters Catalogue-EN (2026.8.19)

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesModel code carries the -EU suffix; certification list EN62109-1/-2, EN61000, EN50549-1/-10, UNE27001/UNE27002, G99, G100 — European 230 V single-phase product.