Identity

category inverters
manufacturer SAJ
model C6-125K-T12-40
region GLOBAL
variant 3-phase

Electrical

ac_voltage_v 3+N+PE, 230/400
C6-(75-125K)-(T6,T9,T12) datasheet en Global
cooling_method Intelligent Fan cooling
C6-(75-125K)-(T6,T9,T12) datasheet en Global
dc_switch True
C6-(75-125K)-(T6,T9,T12) datasheet en Global
european_efficiency_percent 98.5
C6-(75-125K)-(T6,T9,T12) datasheet en Global
grid_frequency_hz 50, 60 / 45~55, 55~65
C6-(75-125K)-(T6,T9,T12) datasheet en Global
max_efficiency_percent 98.8
C6-(75-125K)-(T6,T9,T12) datasheet en Global
max_input_current_per_mppt_a 40
C6-(75-125K)-(T6,T9,T12) datasheet en Global
max_pv_power_w 250000
C6-(75-125K)-(T6,T9,T12) datasheet en Global
max_pv_voltage_v 1100
C6-(75-125K)-(T6,T9,T12) datasheet en Global
mppt_voltage_max_v 1000
C6-(75-125K)-(T6,T9,T12) datasheet en Global
mppt_voltage_min_v 180
C6-(75-125K)-(T6,T9,T12) datasheet en Global
number_of_mppt 12
C6-(75-125K)-(T6,T9,T12) datasheet en Global
phase_count 3
C6-(75-125K)-(T6,T9,T12) datasheet en Global
power_factor_range 0.8 leading~0.8 lagging
C6-(75-125K)-(T6,T9,T12) datasheet en Global
rated_ac_power_kw 125
C6-(75-125K)-(T6,T9,T12) datasheet en Global
rated_dc_voltage_v 600
C6-(75-125K)-(T6,T9,T12) datasheet en Global
topology Non-isolated
C6-(75-125K)-(T6,T9,T12) datasheet en Global

Physical / mechanical

depth_mm 361
C6-(75-125K)-(T6,T9,T12) datasheet en Global
height_mm 660
C6-(75-125K)-(T6,T9,T12) datasheet en Global
width_mm 1045
C6-(75-125K)-(T6,T9,T12) datasheet en Global

Environment

ip_rating IP66
C6-(75-125K)-(T6,T9,T12) datasheet en Global
operating_temperature_max_c 60
C6-(75-125K)-(T6,T9,T12) datasheet en Global
operating_temperature_min_c -30
C6-(75-125K)-(T6,T9,T12) datasheet en Global

Interfaces & connectors

communications ['RS232 (USB)', 'RS485 (RJ45)', 'DRM', 'optional Wi-Fi/Ethernet/4G/PLC']
C6-(75-125K)-(T6,T9,T12) datasheet en Global
documented_ports [{'port_role': 'RS485', 'port_label_from_manual': 'RS485(RJ45)', 'port_type': 'RS485 on RJ45', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'General parameters', 'quote': 'Communication RS232(USB)+RS485(RJ45)+DRM'}, {'port_role': 'RS232', 'port_label_from_manual': 'RS232(USB)', 'port_type': 'RS232 via USB', 'direction': 'bidirectional', 'electrical_domain': 'communication', 'document': 0, 'page': 'General parameters', 'quote': 'Communication RS232(USB)+RS485(RJ45)+DRM'}, {'port_role': 'DIGITAL_IN', 'port_label_from_manual': 'DRM', 'port_type': 'DRM / demand response', 'direction': 'input', 'electrical_domain': 'communication', 'document': 0, 'page': 'General parameters', 'quote': 'Communication RS232(USB)+RS485(RJ45)+DRM'}]

Protection

protection_functions ['AFCI', 'DC/AC Type II SPD', 'GFCI', 'DCI', 'Anti-islanding']
C6-(75-125K)-(T6,T9,T12) datasheet en Global

Документи

datasheet C6-(75-125K)-(T6,T9,T12) datasheet en Global
product_page SAJ C6 Series
product_page SAJ Download Center

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesDatasheet is the '_en_Global' edition; the AC specification printed is 3+N+PE 230/400 V.