SAKO SUNIN-6KM3-L1P3-EU
Manufacturer documented EU перевірено 23 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | SAKO |
| model | SUNIN-6KM3-L1P3-EU |
| region | EU |
| variant | 3-phase |
Electrical
| backup_output |
True
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| battery_max_charging_voltage_v |
60
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| battery_nominal_voltage_v |
48
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| battery_round_trip_efficiency_percent |
94.5
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| battery_supported |
True
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| battery_voltage_class |
LV
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| european_efficiency_percent |
97.5
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| grid_frequency_hz |
50
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| grid_standards |
['IEC61727', 'EN50549-1', 'VDE-4105', 'NRS-097-2-1', 'OVE-Richtlinie R25', 'UNE217001/2', 'Ordinace No.140']
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| has_internal_pv_input |
True
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_ac_output_current_a |
10.0
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_ac_power_w |
6600
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_charge_current_a |
120
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_discharge_current_a |
120
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_efficiency_percent |
98.0
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_input_current_per_mppt_a |
[20, 20]
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_pv_power_w |
10000
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| max_pv_voltage_v |
1000
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| mppt_voltage_max_v |
800
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| mppt_voltage_min_v |
200
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| nominal_grid_voltage_v |
400
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| number_of_mppt |
2
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| peak_output_power |
>200%, 15sec
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| phase_count |
3
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| power_factor |
1 (0.8 leading ~ 0.8 lagging)
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| rated_ac_output_current_a |
9.1
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| rated_ac_power_w |
6000
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| startup_voltage_v |
150
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| topology |
High-frequency Isolation (Battery Side)
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
Physical / mechanical
| dimensions_mm |
[475, 683, 256]
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| weight_kg |
38
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
Environment
| operating_temperature_max_c |
60
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| operating_temperature_min_c |
-25
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
Interfaces & connectors
| documented_ports | [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV Input Parameters — Maximum Input Current (A): 20A/20A', 'port_type': 'DC input', 'direction': 'input', 'electrical_domain': 'DC', 'limits': {'max_pv_voltage_v': 1000, 'max_input_current_per_mppt_a': 20}, 'document': 0, 'page': 'Technical parameter table, PV Input Parameters', 'quote': 'Maximum Input Current (A): 20A/20A'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery Input Parameters', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 0, 'page': 'Technical parameter table, Battery Input Parameters', 'quote': 'Rated Battery Voltage (V): 48V'}, {'port_role': 'GRID', 'port_label_from_manual': 'AC Output Parameters (Grid-tied)', 'port_type': 'AC terminal', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 0, 'page': 'Technical parameter table, AC Output Parameters (Grid-tied)', 'quote': 'Rated Output Voltage (V): 380/400V'}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'AC Output Parameters (Off-grid)', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Technical parameter table, AC Output Parameters (Off-grid)', 'quote': 'Rated Output Voltage (V): 380/400V'}] |
Protection
| ingress_protection |
IP66
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
| protections |
['PV Reverse Polarity', 'PV Insulation Resistance Detection', 'Residual Current Detection', 'Output Overcurrent', 'Output Short-circuit', 'Output Overvoltage']
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
Certifications
| certifications |
['IEC62109', 'IEC61000', 'IS16169', 'IS16221 (BIS)', 'IEC61683', 'IEC62116', 'EN50530', 'IEC60068']
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
|
Документи
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | partial |
| region_notes | European three-phase product ('L1P3' in the designation, 'Rated Output Voltage (V): 380/400V', grid compliance to EN50549-1, VDE-4105, OVE R25, UNE217001/2). The same table lists further columns whose headings end '-ATEU' while SAKO's product listing spells them '-EU'; those are reported as REVIEW_IDENTITY and were not created. |