⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

SAKO SUNIN-8KM3-L1P3-EU

Побудувати систему з цим продуктом

Manufacturer documented EU перевірено 23 вересня 2026 р.

Identity

category inverters
manufacturer SAKO
model SUNIN-8KM3-L1P3-EU
region EU
variant 3-phase

Electrical

backup_output True
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
battery_max_charging_voltage_v 60
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
battery_nominal_voltage_v 48
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
battery_round_trip_efficiency_percent 94.5
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
battery_supported True
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
battery_voltage_class LV
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
european_efficiency_percent 97.5
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
grid_frequency_hz 50
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
grid_standards ['IEC61727', 'EN50549-1', 'VDE-4105', 'NRS-097-2-1', 'OVE-Richtlinie R25', 'UNE217001/2', 'Ordinace No.140']
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
has_internal_pv_input True
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_ac_output_current_a 13.4
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_ac_power_w 8800
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_charge_current_a 160
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_discharge_current_a 160
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_efficiency_percent 98.0
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_input_current_per_mppt_a [20, 20]
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_pv_power_w 12000
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
max_pv_voltage_v 1000
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
mppt_voltage_max_v 800
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
mppt_voltage_min_v 200
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
nominal_grid_voltage_v 400
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
number_of_mppt 2
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
peak_output_power >200%, 15sec
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
phase_count 3
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
power_factor 1 (0.8 leading ~ 0.8 lagging)
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
rated_ac_output_current_a 12.1
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
rated_ac_power_w 8000
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
startup_voltage_v 150
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
topology High-frequency Isolation (Battery Side)
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)

Physical / mechanical

dimensions_mm [475, 683, 256]
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
weight_kg 38
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)

Environment

operating_temperature_max_c 60
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
operating_temperature_min_c -25
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)

Interfaces & connectors

documented_ports [{'port_role': 'PV_IN', 'port_label_from_manual': 'PV Input Parameters — Maximum Input Current (A): 20A/20A', 'port_type': 'DC input', 'direction': 'input', 'electrical_domain': 'DC', 'limits': {'max_pv_voltage_v': 1000, 'max_input_current_per_mppt_a': 20}, 'document': 0, 'page': 'Technical parameter table, PV Input Parameters', 'quote': 'Maximum Input Current (A): 20A/20A'}, {'port_role': 'BATTERY', 'port_label_from_manual': 'Battery Input Parameters', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'document': 0, 'page': 'Technical parameter table, Battery Input Parameters', 'quote': 'Rated Battery Voltage (V): 48V'}, {'port_role': 'GRID', 'port_label_from_manual': 'AC Output Parameters (Grid-tied)', 'port_type': 'AC terminal', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'document': 0, 'page': 'Technical parameter table, AC Output Parameters (Grid-tied)', 'quote': 'Rated Output Voltage (V): 380/400V'}, {'port_role': 'AC_OUT', 'port_label_from_manual': 'AC Output Parameters (Off-grid)', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'document': 0, 'page': 'Technical parameter table, AC Output Parameters (Off-grid)', 'quote': 'Rated Output Voltage (V): 380/400V'}]

Protection

ingress_protection IP66
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)
protections ['PV Reverse Polarity', 'PV Insulation Resistance Detection', 'Residual Current Detection', 'Output Overcurrent', 'Output Short-circuit', 'Output Overvoltage']
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)

Certifications

certifications ['IEC62109', 'IEC61000', 'IS16169', 'IS16221 (BIS)', 'IEC61683', 'IEC62116', 'EN50530', 'IEC60068']
SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)

Документи

product_page SAKO — IP66 SUNIN-12K-L1P3-EU hybrid inverter, technical parameter table (three-phase L1P3 family)

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

builder_completenesspartial
region_notesEuropean three-phase product ('L1P3' in the designation, 'Rated Output Voltage (V): 380/400V', grid compliance to EN50549-1, VDE-4105, OVE R25, UNE217001/2). The same table lists further columns whose headings end '-ATEU' while SAKO's product listing spells them '-EU'; those are reported as REVIEW_IDENTITY and were not created.