⚡ANMAПобудова системAutomation, Network, Monitoring & Analytics

База знань › Inverters

SMA SB5.0-1AV-41 (Sunny Boy 5.0)

Побудувати систему з цим продуктом

Official manufacturer EU перевірено 22 вересня 2026 р.

Identity

brand SMA
category inverters
ean —
generation AV-41 (with SMA Smart Connected)
manufacturer SMA Solar Technology AG суперечливе
market_version EU / international en datasheet SB30-60-DS-en-61 (an AU variant SB30-60-DS-AU-61 also exists on files.sma.de)
model SB5.0-1AV-41 (Sunny Boy 5.0)
mpn SB5.0-1AV-41
product_family SMA Sunny Boy AV-41
product_revision -41
product_status active
region EU
release_year —
sku —

Electrical

ac_coupling_support —
backup_eps_output_support False
battery_support False
battery_type —
battery_voltage_class —
battery_voltage_max_v —
battery_voltage_min_v —
communication_can —
communication_ethernet True
communication_rs485 True
communication_wifi yes (depending on availability)
ct_support —
generator_input_support False
grid_certifications ['AS 4777.2', 'C10/11', 'CE', 'CEI 0-21', 'Dansk Energi DK1/2', 'DEWA', 'DIN EN 62109 / IEC 62109', 'EN 50438', 'EN 50549-1', 'G98/1', 'G99/1', 'IEC 61727', 'IEC 62116', 'IE-EN50438', 'NBR 16149', 'NEN-EN50438', 'NRS 097-2-1', 'NT_Ley20.571', 'OEVE/OENORM E 8001-4-712 & TOR Erzeuger Typ A', 'PPC', 'PPDS', 'RD1699', 'RfG compliant', 'SI 4777', 'UTE C15-712', 'VDE 0126-1-1', 'VDE-AR-N 4105', 'VFR 2014']
grid_export_control —
home_assistant_integration —
max_ac_power_kw 5
max_battery_charge_current_a —
max_battery_charge_power_kw —
max_battery_discharge_current_a —
max_dc_voltage_v 600
SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0 with SMA SMART CONNECTED - Datasheet — Input (DC), 'Max. input voltage' = '600 V'
max_input_current_per_mppt_a 15 (input A) / 15 (input B) - per MPP input
SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0 with SMA SMART CONNECTED - Datasheet — Input (DC), 'Max. usable input current input A / input B' = '15 A / 15 A'
max_pv_input_power_w 7500
max_short_circuit_current_per_mppt_a 20 (input A) / 20 (input B)
SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0 with SMA SMART CONNECTED - Datasheet — Input (DC), 'Max. DC short-circuit current input A / input B' = '20 A / 20 A'
modbus_rtu —
modbus_tcp True
mppt_max_voltage_v 500
mppt_min_voltage_v 175
num_mppt 2
officially_supported_battery_brands []
phase_type single-phase
pv_inputs_per_mppt 2 strings per MPP input (A: 2; B: 2)
rated_ac_power_kw 5
smart_meter_support —
startup_voltage_v 125
sunspec_support True
topology grid-tie

Physical / mechanical

bracket_dimensions_mm —
cable_entry_positions —
cable_gland_sizes —
depth_mm 176
enclosure_material —
height_mm 470
housing_color —
mounting_bolt_size 3 screws suitable for the support surface and the weight of the inverter, diameter minimum 6 mm, with 3 washers of minimum 18 mm outer diameter; the inverter is secured to the wall mounting bracket with a pan head screw M5x12
mounting_hole_diameter_mm centre keyhole diameter 9 mm; the other anchor points are 9 x 18 mm slots
mounting_hole_spacing_mm 311 +/- 0.5 horizontally between the two outer anchor points (product width 435 mm); vertically: upper anchor line 172 mm below the top and 298 mm above the bottom of the 470 mm-high product, with intermediate dimensions 30, 90, 120 +/- 0.5 and 150 +/- 0.5 mm
SUNNY BOY 3.0-6.0 (AV-41) - Operating/installation manual, chapter 'Requirements for Mounting' (HTML) — Requirements for Mounting > Dimensions for mounting, 'Position of the anchoring points (Dimensions in mm)' drawing (read from the rendered drawing in the browser)
mounting_type ['wall', 'pole']
screw_sizes M5x12 pan head (TX25) securing screw; wall screws minimum 6 mm diameter
shipping_weight_kg —
terminal_locations —
torque_specs securing screw to the wall mounting bracket: TX25, torque 2.5 N.m
SUNNY BOY 3.0-6.0 (AV-41) - Manual chapter 'Mounting the product' (HTML) — Mounting the product - 'pan head screw (M5x12)', 'TX25, torque: 2.5 Nm'
weight_kg 17.5
width_mm 435
SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0 with SMA SMART CONNECTED - Datasheet — General data, 'Dimensions (W / H / D)' = '435 mm / 470 mm / 176 mm'

Installation

altitude_derating_note —
clearance_bottom_mm 430
clearance_front_mm 100
clearance_left_mm 210 to a wall or object; 270 between two inverters mounted side by side
clearance_right_mm 210 to a wall or object; 270 between two inverters mounted side by side
clearance_top_mm 450
SUNNY BOY 3.0-6.0 (AV-41) - Operating/installation manual, chapter 'Requirements for Mounting' (HTML) — Requirements for Mounting > Recommended clearances (Dimensions in mm) drawing
cooling_airflow_requirements maintain the recommended clearances to walls as well as to other inverters or objects so that adequate heat dissipation is ensured
direct_sunlight_restriction The installation site must not be exposed to direct solar irradiation. If the product is exposed to direct solar irradiation, the exterior plastic parts might age prematurely and overheating might occur. When becoming too hot, the product reduces its power output to avoid overheating.
indoor_outdoor indoor and outdoor (IP65)
installation_humidity_range —
installation_temperature_range_c to ensure optimum operation, the ambient temperature should be between -25 C and +40 C
max_installation_altitude_m —
minimum_wall_thickness_mm —
mounting_orientation vertical wall (or post) mounting in a permitted position only, so that no moisture can penetrate the product; mount so that the LED signals can be read off without difficulty
orientation_allowed ['vertical on a wall or post']
orientation_forbidden ['any position other than the single permitted vertical position shown in the manual (tilted, horizontal, connection area upwards, face up, face down)']
special_restrictions Do not mount the product in areas containing highly flammable materials or gases, or in potentially explosive atmospheres. The mounting location must be inaccessible to children. The installation site should be freely and safely accessible at all times without auxiliary equipment. The DC load-break switch must always be freely accessible.
surface_requirements A solid support surface must be available (e.g., concrete or masonry). When mounted on drywall or similar materials, the product emits audible vibrations during operation which could be perceived as annoying. The installation site must be suitable for the weight and dimensions of the product.
two_person_lift_required —
ventilation_requirements If multiple products are mounted in areas with high ambient temperatures, increase the clearances between the products and ensure sufficient fresh-air supply.

Environment

cooling_method convection (fanless)
corrosion_class —
ik_rating —
ip_rating IP65
max_altitude_m —
nema_rating —
noise_level_db 25 dB(A) typical
operating_temperature_c -25 to +60
pollution_degree —
relative_humidity max. permissible relative humidity 100%
salt_mist_resistance —
storage_temperature_c —
uv_resistance —

Interfaces & connectors

ac_terminal_type AC connector
analog_inputs —
auxiliary_power_output —
backup_eps_terminal —
battery_terminal_type —
bluetooth —
can —
cellular —
cloud_api Webconnect (Sunny Portal); SMA Smart Connected service
digital_inputs —
dry_contacts —
ethernet Ethernet (standard equipment)
generator_start_contact —
generator_terminal —
local_api —
modbus_tcp Modbus (SMA, SunSpec)
mqtt —
ocpp —
programmable_relay —
protocol_notes Communication protocols listed: Modbus (SMA, SunSpec), Webconnect, SMA Data.
pv_connector_type SUNCLIX
rapid_shutdown_interface —
relay_outputs —
rs232 —
rs485 RS485 (listed in the datasheet interface row)
smart_load_output —
sunspec yes (SunSpec Modbus profile)
usb —
wifi WLAN (depending on availability)
zigbee —

Controls & display

audible_alarm —
buttons —
display_type none (LED signals)
leds LED signals (must be readable from the mounting position)
local_display False
mobile_app —
remote_display_option —
status_indicators LED
touchscreen False
web_interface yes (integrated user interface)

Protection

afci —
anti_islanding yes (IEC 62116 and the listed grid codes)
ground_fault_protection —
insulation_monitoring —
integrated_breakers_fuses —
integrated_dc_switch yes (the manual requires the DC load-break switch to remain freely accessible)
over_current —
over_temperature the product reduces its power output to avoid overheating
over_voltage —
overvoltage_category III
protection_class I
residual_current_monitoring —
reverse_polarity —
short_circuit —
surge_protection —
under_voltage —

Certifications

emc ['UNKNOWN']
grid_codes ['AS 4777.2', 'C10/11', 'CEI 0-21', 'Dansk Energi DK1/2', 'DEWA', 'EN 50438', 'EN 50549-1', 'G98/1', 'G99/1', 'IEC 61727', 'IEC 62116', 'IE-EN50438', 'NBR 16149', 'NEN-EN50438', 'NRS 097-2-1', 'NT_Ley20.571', 'OEVE/OENORM E 8001-4-712 & TOR Erzeuger Typ A', 'PPC', 'PPDS', 'RD1699', 'RfG compliant', 'SI 4777', 'UTE C15-712', 'VDE 0126-1-1', 'VDE-AR-N 4105', 'VFR 2014']
other []
regional ['CE']
safety ['DIN EN 62109', 'IEC 62109']

Warranty & service

conditions Datasheet warranty row: '5 / 10 years' (10-year option).
cycle_life —
design_life_years —
extended_options_years [10]
fan_replaceable —
field_replaceable_parts []
fuse_replaceable —
service_intervals —
standard_years 5

Packaging & logistics

gross_weight_kg —
package_depth_mm —
package_height_mm —
package_width_mm —
transport_restrictions —
units_per_pallet —

Документи

datasheet SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0 with SMA SMART CONNECTED - Datasheet rev SB30-60-DS-en-61, status 10/2023
datasheet {# Located but never retrieved: listed, but deliberately not linked, and it backs no stored value. #} SUNNY BOY 3.0 / 4.0 / 5.0 / 6.0 - Datasheet, AU revision — знайдено, не отримано rev SB30-60-DS-AU-61
installation-manual SUNNY BOY 3.0-6.0 (AV-41) - Manual chapter 'Mounting the product' (HTML) rev UNKNOWN
installation-manual SUNNY BOY 3.0-6.0 (AV-41) - Operating/installation manual, chapter 'Requirements for Mounting' (HTML) rev UNKNOWN
manual SMA Sunny Boy 3.0/3.6/4.0/5.0/6.0 (SBxx-1AV-41) operating manual — Technical Data, DC input (SB5.0/6.0) rev online manual, en-US
product_page Sunny Boy 3.0/3.6/4.0/5.0/6.0 (SBxx-1AV-41) - product page

Зафіксовані конфлікти

identity.manufacturer Review required
SMA Solar Technology AG — stored value
SMA — incoming package
Detected during import v1-freeze-2026-09-batch09
identity.manufacturer Review required
SMA Solar Technology AG — stored value
SMA — incoming package
Detected during import v1-freeze-2026-09-batch09
identity.manufacturer Review required
SMA Solar Technology AG — stored value
SMA — incoming package
Detected during import inverter-mppt-topology-2026-09-batch06

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Max. efficiency / European Efficiency97.0% / 96.5%
Min. input voltage / initial input voltage100 V / 125 V
Rated / Max. output current22 A / 22.8 A
Rated input voltage365 V
Rated voltage / range220 V, 230 V, 240 V / 180 V to 280 V
Recommended ambient temperature for optimum operation-25 C to +40 C
Self-consumption (at night)5.0 W