Sol-Ark 12K-2P-LL
Official manufacturer NA перевірено 25 вересня 2026 р.
Identity
| category | inverters |
| manufacturer | Sol-Ark |
| model | 12K-2P-LL |
| region | — |
Electrical
| ac_voltage_range |
185 - 275 V
12K-2P-LL Datasheet V4.0 (EN)
|
| ac_voltage_v |
120/240, 120/208
12K-2P-LL Datasheet V4.0 (EN)
|
| automatic_generator_start |
True
12K-2P-LL Datasheet V4.0 (EN)
|
| backup_continuous_power_w |
[10000, 8660]
12K-2P-LL Datasheet V4.0 (EN)
|
| backup_surge_power_10s_w |
[24000, 20800]
12K-2P-LL Datasheet V4.0 (EN)
|
| backup_voltage_v |
120/240, 120/208
12K-2P-LL Datasheet V4.0 (EN)
|
| battery_technology |
Lead-acid or Lithium
12K-2P-LL Datasheet V4.0 (EN)
|
| battery_terminal_current_rating_a |
300
12K-2P-LL Datasheet V4.0 (EN)
|
| battery_voltage_max_v |
59
12K-2P-LL Datasheet V4.0 (EN)
|
| battery_voltage_min_v |
43
12K-2P-LL Datasheet V4.0 (EN)
|
| battery_voltage_nominal_v |
48
12K-2P-LL Datasheet V4.0 (EN)
|
| gen_port_max_current_a |
60
12K-2P-LL Datasheet V4.0 (EN)
|
| grid_frequency_hz |
50 / 60
12K-2P-LL Datasheet V4.0 (EN)
|
| idle_consumption_w |
96
12K-2P-LL Datasheet V4.0 (EN)
|
| max_ac_coupled_pv_power_w |
[14000, 12410]
12K-2P-LL Datasheet V4.0 (EN)
|
| max_charge_current_a |
220
12K-2P-LL Datasheet V4.0 (EN)
|
| max_discharge_current_a |
220
12K-2P-LL Datasheet V4.0 (EN)
|
| max_efficiency_percent |
97.6
12K-2P-LL Datasheet V4.0 (EN)
|
| max_generator_power_w |
[14000, 12410]
12K-2P-LL Datasheet V4.0 (EN)
|
| max_output_current_a |
50
12K-2P-LL Datasheet V4.0 (EN)
|
| max_parallel_units |
12
12K-2P-LL Datasheet V4.0 (EN)
|
| max_passthrough_current_a |
100
12K-2P-LL Datasheet V4.0 (EN)
|
| max_pv_current_a |
32
12K-2P-LL Datasheet V4.0 (EN)
|
| max_pv_power_w |
19200
12K-2P-LL Datasheet V4.0 (EN)
|
| max_pv_voltage_v |
500
12K-2P-LL Datasheet V4.0 (EN)
|
| max_short_circuit_current_a |
60
12K-2P-LL Datasheet V4.0 (EN)
|
| max_usable_pv_power_w |
12000
12K-2P-LL Datasheet V4.0 (EN)
|
| mppt_voltage_max_v |
425
12K-2P-LL Datasheet V4.0 (EN)
|
| mppt_voltage_min_v |
150
12K-2P-LL Datasheet V4.0 (EN)
|
| number_of_battery_inputs |
4
12K-2P-LL Datasheet V4.0 (EN)
|
| number_of_mppt |
3
12K-2P-LL Datasheet V4.0 (EN)
|
| parallel_supported |
True
12K-2P-LL Datasheet V4.0 (EN)
|
| power_factor_range |
+/- 0.9
12K-2P-LL Datasheet V4.0 (EN)
|
| rated_ac_power_w |
12000
12K-2P-LL Datasheet V4.0 (EN)
|
| startup_voltage_v |
125
12K-2P-LL Datasheet V4.0 (EN)
|
| strings_per_mppt |
2
12K-2P-LL Datasheet V4.0 (EN)
|
| thd_percent |
1.6
12K-2P-LL Datasheet V4.0 (EN)
|
| thdi_percent |
2.5
12K-2P-LL Datasheet V4.0 (EN)
|
| transfer_time_ms |
5
12K-2P-LL Datasheet V4.0 (EN)
|
| warranty_years |
10
12K-2P-LL Datasheet V4.0 (EN)
|
Physical / mechanical
| depth_mm |
249.5
12K-2P-LL Datasheet V4.0 (EN)
|
| height_mm |
653
12K-2P-LL Datasheet V4.0 (EN)
|
| weight_kg |
29.5
12K-2P-LL Datasheet V4.0 (EN)
|
| width_mm |
421.4
12K-2P-LL Datasheet V4.0 (EN)
|
Installation
| mounting |
Wall (hanging bracket included)
12K-2P-LL Datasheet V4.0 (EN)
|
Environment
| ip_rating |
IP65 / NEMA 3R
12K-2P-LL Datasheet V4.0 (EN)
|
| operating_temperature_max_c |
60
12K-2P-LL Datasheet V4.0 (EN)
|
| operating_temperature_min_c |
-40
12K-2P-LL Datasheet V4.0 (EN)
|
Interfaces & connectors
| bms_interface |
CANbus / RS485 / MODBUS RTU
12K-2P-LL Datasheet V4.0 (EN)
|
| communications |
['Wi-Fi', 'LAN']
12K-2P-LL Datasheet V4.0 (EN)
|
| documented_ports | [{'port_role': 'GRID', 'port_label_from_manual': 'Grid (AC)', 'port_type': 'AC terminal block', 'direction': 'bidirectional', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 100, 'document': 1, 'page': 'Sol-Ark 12K-2P-LL Datasheet PS-00045 Rev 4 (9 Sept 2026) - specification table', 'quote': 'Grid (AC): Max. Passthrough Current (Grid to Load) | A | 100'}, {'port_role': 'PV_IN', 'port_label_from_manual': 'PV (DC)', 'port_type': 'DC input', 'direction': 'input', 'electrical_domain': 'DC', 'quantity': 6, 'max_current_a': 32, 'document': 1, 'page': 'Sol-Ark 12K-2P-LL Datasheet PS-00045 Rev 4 (9 Sept 2026) - specification table', 'quote': 'PV (DC): Number of MPPT / Strings per MPPT | 3/2 ; PV (DC): Number of MPPT / Strings per MPPT | 3/2'}, {'port_role': 'BATTERY_DC', 'port_label_from_manual': 'Battery (DC)', 'port_type': 'DC terminal', 'direction': 'bidirectional', 'electrical_domain': 'DC', 'quantity': 4, 'max_current_a': 220, 'document': 1, 'page': 'Sol-Ark 12K-2P-LL Datasheet PS-00045 Rev 4 (9 Sept 2026) - specification table', 'quote': 'Battery (DC): Number of Inputs | 4'}, {'port_role': 'GENERATOR', 'port_label_from_manual': 'GEN Port (AC)', 'port_type': 'AC terminal', 'direction': 'input', 'electrical_domain': 'AC', 'quantity': 1, 'max_current_a': 60, 'document': 1, 'page': 'Sol-Ark 12K-2P-LL Datasheet PS-00045 Rev 4 (9 Sept 2026) - specification table', 'quote': 'GEN Port (AC): Max. Current | A | 60'}, {'port_role': 'BACKUP_LOAD', 'port_label_from_manual': 'Backup - Off-Grid (AC)', 'port_type': 'AC terminal', 'direction': 'output', 'electrical_domain': 'AC', 'quantity': 1, 'document': 1, 'page': 'Sol-Ark 12K-2P-LL Datasheet PS-00045 Rev 4 (9 Sept 2026) - specification table', 'quote': 'Backup - Off-Grid (AC): Max. Continuous Power | W | 10,000 | 8,660 (axis: 120/240 V then 120/208 V)'}] |
Документи
datasheet
12K-2P-LL Datasheet V4.0 (EN)
installation_manual
12K-2P-LL Installation & Manual V3.0 (EN)
product_page
Sol-Ark 12K-2P-LL product page
quick_start_guide
12K-2P-LL Quickstart Guide V2.0 (EN)
Додаткові задокументовані параметри
Записано дослівно з джерела; поля схеми для них поки немає.
| builder_completeness | complete |
| region_notes | North American 60 Hz split-phase / 208 V product; UL 1741 listed, sold in the US and Canada. |