Identity

brand SolarEdge
category inverters
ean —
generation —
manufacturer SolarEdge
market_version Europe (datasheet 'for Europe', doc code DS-000112-ENG)
model SE10K-RWB48 (Home Hub Inverter, three-phase with backup)
mpn —
product_family SolarEdge Home Hub Inverter Three Phase with Backup (SE5K-RWB48 / SE8K-RWB48 / SE10K-RWB48)
product_revision —
product_status active
region Europe / RoW
release_year —
sku SE10K-RWB48

Electrical

ac_coupling_support —
backup_eps_output_support True
backup_switchover_time Automatic Switchover Time <= 6 Sec
battery_support True
battery_supported True
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
battery_type SolarEdge Home Battery BAT-05K48 (1-5 modules)
battery_voltage_class LV
battery_voltage_max_v 62
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
battery_voltage_min_v 40
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
communication_can —
communication_ethernet True
communication_rs485 True
communication_wifi True
ct_support —
firmware_requirements Supported use cases doc v1.5 (Feb 2025): 'Inverters: 4.19 or later' and 'Battery: 1.126 or later'
SolarEdge Home Hub Three Phase Inverter - Supported Use Cases / Connection and Configuration Options (EU) — use-cases doc v1.5, 'Inverters: 4.19 or later' / 'Battery: 1.126 or later'
generator_input_support —
grid_certifications ['IEC 62109', 'VDE-AR-N 4105', 'EN 50549-1', 'CEI 0-21']
grid_export_control —
home_assistant_integration —
max_ac_power_kw 10
max_ac_power_va 10000
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
max_battery_charge_current_a 125
max_battery_charge_power_kw 5
max_battery_discharge_current_a 125
max_charge_power_w 5000
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
max_continuous_battery_current_a 125
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
max_dc_power_w 20000
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
max_dc_voltage_v —
max_discharge_power_w 5000
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
max_input_current_a 20.0
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
max_input_current_per_mppt_a 20
max_parallel_units 3 in backup mode (one Leader + 'Up to two inverters from the supported types' as Followers, use-cases doc v1.5)
max_pv_input_power_w 20000
max_short_circuit_current_per_mppt_a —
modbus_rtu —
modbus_tcp —
mppt_max_voltage_v 900
mppt_min_voltage_v 750
mppt_voltage_max_v 900
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
mppt_voltage_min_v 750
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
nominal_grid_voltage_v 380/220; 400/230
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
num_mppt —
officially_supported_battery_brands ['SolarEdge Home Battery (proprietary)']
SolarEdge Home Hub Three Phase Inverter - Supported Use Cases / Connection and Configuration Options (EU) — use-cases doc v1.5, 'SolarEdge Home Battery 48V BAT-05K48M0B-01 BAT-05K48M0B-02'
phase_count 3
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
phase_type three-phase
pv_inputs_per_mppt —
rated_ac_power_kw 10
rated_ac_power_per_phase_va 3333
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
rated_ac_power_va 10000
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet
smart_meter_support —
startup_voltage_v —
sunspec_support —
topology hybrid

Physical / mechanical

bracket_dimensions_mm —
cable_entry_positions —
cable_gland_sizes AC output gland diameter 15-21 mm; two communication glands, each taking 2 x CAT 5E plus one RF antenna cable (installation guide p.23)
depth_mm 192
enclosure_material —
height_mm 907
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet installation specification, 'Dimensions (H x W x D) 907 x 317 x 192 mm'
housing_color —
mounting_bolt_size two supplied screws through the outer heat sink fins, torqued to '4.0 N*m / 2.9 lb.*ft'; at least two outer bracket holes to be used (installation guide p.25)
mounting_hole_diameter_mm —
mounting_hole_spacing_mm —
mounting_type ['wall', 'stud framing', 'pole']
shipping_weight_kg —
terminal_locations —
torque_specs bracket side screws 4 N·m; DC (battery) terminals 8 N·m (installation guide p.33); AC terminal screws 1.5 N·m; AC gland 2.8-3.3 N·m; communication glands 3.5 N·m; antenna bracket screws 2.2 N·m (compact guide)
SolarEdge Home Hub Inverter - Three Phase, For Europe and APAC - Installation Guide — installation guide p.25 (4.0 N*m), p.33 (DC 8 N*m), p.35 (gland 2.2 N*m); compact guide AC 1.5 N*m, AC gland 2.8-3.3 N*m, comm glands 3.5 N*m
weight_kg 37
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet installation specification, 'Weight 37 kg'
width_mm 317

Installation

clearance_bottom_mm 200
clearance_front_mm 1000
clearance_left_mm 200
clearance_right_mm 200
clearance_top_mm 200
SolarEdge Home Hub Inverter - Three Phase - compact/quick guide — compact guide: 'keep 20 cm from the top and bottom, 20 cm from the sides, and one meter from the front'
detailed_clearance_reference 'To allow for proper heat dissipation, follow the guidelines specified in Application Note - Clearance Guidelines' (installation guide p.24)
direct_sunlight_restriction 'It is recommended to mount the inverter in a location protected from direct sunlight' (installation guide p.24)
indoor_outdoor outdoor and indoor (IP65)
max_installation_altitude_m —
mounting_orientation wall, stud framing or pole (installation guide p.24)
orientation_allowed ['wall', 'stud framing', 'pole']
orientation_forbidden —
surface_requirements —

Environment

cooling_method Fans
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet, 'Cooling Fans'
ik_rating —
ip_rating IP65 - outdoor and indoor
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet, 'Protection Rating IP65 - outdoor and indoor'
max_altitude_m —
nema_rating —
noise_level_db < 50 dBA
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet, 'Noise < 50 dBA'
operating_temperature_c -40 to +60
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet, 'Operating Temperature Range -40 to +60 degC'
pollution_degree —
relative_humidity —
storage_temperature_c -25 to +65 (installation guide p.12)
SolarEdge Home Hub Inverter - Three Phase, For Europe and APAC - Installation Guide — installation guide p.12, '-25 degC to +65 degC / -13 degF to 149 degF'

Interfaces & connectors

ac_terminal_type AC input terminal blocks, max wire size 6 mm2, recommended cross-section 4-6 mm2 (installation guide p.31-32); compact guide gives AC terminals '6-16 mm2'
battery_terminal_type battery DC kit with two battery shoe cables (+ and -); DC cable max length 5 m, double insulation 600 V (installation guide p.11, p.23)
can —
cellular —
ethernet built-in Ethernet (RJ45)
protocol_notes Datasheet 'Supported Communication Interfaces: Built-in: 2 x RS485, Ethernet, SolarEdge Home Network'. Grounding conductor at least 6 mm2.
pv_connector_type two pairs of MC4 connectors (installation guide p.23); DC cable diameter 11-16.5 mm
SolarEdge Home Hub Inverter - Three Phase, For Europe and APAC - Installation Guide — installation guide p.23 Figure 5, 'Two pairs of MC4 connectors'
rs485 2 x RS485 built-in
sunspec —
usb —
wifi SolarEdge Home Network (plug-in); Wi-Fi via communication option

Controls & display

buttons ON/OFF/P switch (P position held 5 s for functions)
display_type none (SetApp commissioning)
leds Green: power production; Blinking Green: grid connection ok; Blue: communication ok; Red: fault (compact guide)
local_display False
mobile_app SolarEdge SetApp (commissioning), mySolarEdge / SolarEdge ONE (monitoring)
touchscreen False

Protection

afci —
anti_islanding —
insulation_monitoring —
integrated_dc_switch SafeDC / DC disconnection: certified for compliance with IEC 60947-3 (installation guide p.59); disconnect by moving P/ON/OFF switch to OFF and waiting 5 minutes
over_current —
over_temperature —
over_voltage —
protection_class transformer-less, ungrounded design
residual_current_monitoring External RCD required; 'The Inverter supports both type A and Type B RCD' (installation guide p.26); datasheet notes 100 mA type-A recommended
surge_protection 'For Ethernet cables exceeding 10 m in lightning-prone areas SolarEdge recommends using external surge protection devices' (installation guide p.43)

Certifications

emc ['IEC 61000-6-2', 'IEC 61000-6-3', 'IEC 61000-3-11', 'IEC 61000-3-12', 'EN 55011']
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet 'Emissions' row
grid_codes ['VDE-AR-N 4105', 'Tor Erzeuger Typ A', 'EN 50549-1', 'CEI 0-21', 'G98 Type A', 'G98 NI Type A', 'RD1699 / RD413 / NTS', 'VDE-V 0126-1-1', 'VFR 2019', 'C10/11', 'EN 50438', 'VDE 2510-2']
SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet — datasheet 'Grid Connection Standards' row
other []
regional ['RoHS']
safety ['IEC 62109', 'IEC 60947-3 (DC disconnection device compliance)']

Документи

compatibility-list SolarEdge Home Hub Three Phase Inverter - Supported Use Cases / Connection and Configuration Options (EU) rev Version 1.5
datasheet SolarEdge Home Hub Inverter Three Phase with Backup, for Europe - datasheet rev DS-000112-ENG
installation-manual SolarEdge Home Hub Inverter - Three Phase, For Europe and APAC - Installation Guide rev Version 1.1
product-page SolarEdge Home Hub Inverters product page rev UNKNOWN
quick-start SolarEdge Home Hub Inverter - Three Phase - compact/quick guide rev UNKNOWN

Задокументована сумісність

Лише задокументовані пари. Якщо продукту тут немає, це означає, що не отримано документа, який називає цю пару, а не те, що вона несумісна.

inverter_evse

go-e GmbH go-eCharger Gemini (11kW and 22kW variants) COMPATIBLEinferred-from-electrical-parameters
go-e Gemini Datasheet (open local API/Modbus TCP/MQTT) + third-party EMS tools (evcc, openWB)

Зафіксовані конфлікти

interfaces.ac_terminal_type / AC conductor cross-section Review required
Maximum wire size for the input terminal blocks is 6 mm2; recommended cross-section 4-6 mm2 — Installation guide EU/APAC v1.1 (April 2023), p.31-32
AC terminals: 6-16 mm2 — Home Hub Inverter Three Phase compact guide
different document revisions / possibly different terminal-block hardware between guide versions; both are official SolarEdge documents
interfaces.ac_terminal_type / AC conductor cross-section Review required
Maximum wire size for the input terminal blocks is 6 mm2; recommended cross-section 4-6 mm2 — Installation guide EU/APAC v1.1 (April 2023), p.31-32
AC terminals: 6-16 mm2 — Home Hub Inverter Three Phase compact guide
different document revisions / possibly different terminal-block hardware between guide versions; both are official SolarEdge documents

Додаткові задокументовані параметри

Записано дослівно з джерела; поля схеми для них поки немає.

Automatic Switchover Time<= 6 Sec
Battery DC cableMaximum length: 5m, double isolation 600V
Enclosure grounding conductorat least 6 mm2
European Weighted Efficiency97.6%
Maximum Input Current (INPUT PV)20 Adc
Multi-inverter backupUp to two inverters from the supported types (as Followers to a Leader)
Peak efficiency PV to Grid98%
Rated AC Power Output (Total/Per Phase)10000 / 3333 VA
Supported Power Optimizers1:1 Power Optimizers only, of the following types: SolarEdge S-Series, SolarEdge P-Series, SolarEdge OP-Series